background image

5

INSTRUCTIONS FOR THE INSTALLER

Gas connection

Make sure that the appliance is adjusted for 

the gas type available (see the label under the 

appliance). Follow the instructions indicated in the 

chapter “gas transformations and adjustments” for 

the possible adaptation to different gases.

The appliance must be connected to the gas 

system by means of stiff metal pipes or flexible 

steel pipes having continuous walls, in compliance 

with the regulations in force.

Some models are equipped with both cylindrical A 

and conical B connectors for gas supply (fig. 6).

Please select the type which is correct for the 

supply concerned.

The connection must not stress the gas ramp.

 

Once the installation is over, check the 

connection seal with a soapy solution. 

Electric connection

The appliances does not require to be connected 

to the mains power supply as it is provided with a 

low voltage ignition generator supplied by a 1,5V 

battery.

GAS TRANSFORMATIONS AND ADJUSTMENTS

Replacing the nozzles

If the equipment is adjusted for a type of gas that 

is different from the one available, it is necessary 

to replace the burner nozzles.

The choice of the nozzles to replace must be 

made according to the table of the “technical 

characteristics” as enclosed.

Act as follows:

 -Remove the racks and burners.

 -By means of a straight spanner L, unscrew 

the nozzle U (fig.7) and substitute it with the 

corresponding one.

 -Tighten the nozzle strongly.

Adjusting the burners

The lowest flame point must always be properly 

adjusted and the flame must remain on even if 

there is an abrupt shift from the maximum to the 

minimum position.

If this is not so, it is necessary to adjust the lowest 

flame point as follows:

 -start the burner up

 -turn the tap up to the minimum position (small 

flame)

 -remove the knob from the tap rod

 -introduce a flat-tip screwdriver in the hole F of 

the tap (fig.8) and turn the by-pass screw up to a 

proper adjustment of the lowest flame point.

As regards G30 gas burners, the by-pass screw 

must be tightened completely.

MAINTENANCE

Replacing the battery (fig. 9)

 -Unscrew the cap 

T .

 -Replace the battery 

type alkaline AA 1,5 V 

placing it in the spring 

M

 and making sure that the 

“ 

” polarity faces upwards.

 -Fit the battery into the battery holder and screw 

down the cap 

T.

9

Содержание GS04-M1

Страница 1: ...ith quality materials will meet your requirements in the best possible way The use of this new equipment is easy However we invite you to read this booklet carefully before installing and using the appliance This booklet gives the right information on the installation use and maintenance as well asuseful advice THE MANUFACTURER INSTALLATION AND USER INSTRUCTIONS BUILT IN GAS HOB GS04 M1 ...

Страница 2: ...vised to ensure that they do not play with the appliance While the appliance is running watch the children and make sure they neither stay near the equipment nor touch the surfaces that have not cooled down completely Before powering the equipment check that it is properly adjusted for the type of gas at disposal see the installation paragraph Before carrying out the maintenance or cleaning the eq...

Страница 3: ...the safety valve will automatically stop the gas supply after a few seconds To restore operation set the knob to the lighting point large flame fig 1 and press While cooking with fat or oil pay the utmost attention as these substances can catch fire when overheated Do not use sprays near the appliance in operation Do not place unstable or deformed pots on the burner so as to prevent them from over...

Страница 4: ...t be taken to guarantee an installation in accordance with current accident prevention standards Pay particular attention to the position of the electric cable and gas pipe they must not touch any hot parts of the oven Moreover if the hob is going to be installed on the top of a built in oven without forced cooling ventilation proper air vents must be installed to guarantee an adequate ventilation...

Страница 5: ...f gas that is different from the one available it is necessary to replace the burner nozzles The choice of the nozzles to replace must be made according to the table of the technical characteristics as enclosed Act as follows Remove the racks and burners By means of a straight spanner L unscrew the nozzle U fig 7 and substitute it with the corresponding one Tighten the nozzle strongly Adjusting th...

Страница 6: ...6 2 3 4 1 Closed Maximum Minimum 7 F 8 5 6 ...

Страница 7: ...CAL CHARACTERISTIC TABLES BURNERS GAS NORMAL PRESSURE NOMINAL RATE INJECTOR DIAMETER TAPE BY PASS DIAMETER NOMINAL HEAT INPUT W N DESCRIPTION mbar g h 1 100 mm 1 100 mm Max Min 1 RAPID G30 30 218 85 42 3000 950 2 SEMI RAPID G30 30 127 65 31 1750 600 3 AUXILIARY G30 30 73 50 27 1000 450 6 TRIPLE RING G30 30 291 102 60 4000 1500 2 6 1 8 3 ...

Страница 8: ...let due to misprints or clerical errors It reserves the right to make all the changes that it will consider necessary in its own products without effecting the essential characteristics of functionality and safety CUT OUT DIMENSION 1 5 375 402 19 8 1055 1102 23 5 23 5 R 6 1 1 0 0 4 0 0 90 8 4 8 ...

Отзывы: