Caution: Read manual carefully for proper procedures and operation.
• Specifications • Installation • Maintenance
80K Owner’s Manual
Страница 1: ...Caution Read manual carefully for proper procedures and operation Specifications Installation Maintenance 80K Owner s Manual...
Страница 2: ...g the PCO Cell 10 on your purchase of an Duct Pure 80K air purification enhancement system This unit is designed to be installed into an existing HVAC system and used as a virtually maintenance free e...
Страница 3: ...S 8 Self tapping Screws 4 Brass Thumb Nuts The PCO Cell is the only replacement part available for the Duct Pure 80K Please contact your distributor for your new cell replacements PCO Cell Part Number...
Страница 4: ...ns and a safe low level ozone all friendly oxidizers that revert back to oxygen and hydrogen after the oxidation of a pollutant Used in conjunction with other current purification systems Duct Pure 80...
Страница 5: ...HARDWIRING REQUIREMENT To use the 120V plug be sure to locate the unit within 6 ft of a standard 120V grounded outlet Long term use on an extension cord is not recommended due to safety consideration...
Страница 6: ...cation to mount your Induct Unit 2 If necessary cut away insulation for your plate to adhere to the duct 3 Using the Adhesive Gasket Plate trace the hole locations onto the duct 4 Use the Hole Saw and...
Страница 7: ...ive Gasket Plate trace the hole locations onto the duct 2 Drill holes around the outside edges of the prviously marked holes but inside the outer holes of the Adhesive Gasket Plate 3 Use the Tin Snips...
Страница 8: ...sket Plate onto the duct Secure with the 8 Self Tapping Screws 7 Place the Unit and Cells through the openings and secure with the 4 Brass Thumb Nuts 8 Plug the Unit Power Cable into the receptacle or...
Страница 9: ...e UV lamp appears to be operating normally The UV lamp operation indicator on the face of the unit will glow when the UV lamp is in use If the indicator does not glow and the unit has power the PCO ce...
Страница 10: ...Cable from the receptacle or ensure the unit isn t powered 2 Remove the 4 Brass Thumb Nuts from the Unit Cover and Remove the Unit Cover and PCO Cells 3 Remove the 4 Screws holding the PCO Cells in p...
Страница 11: ...CO Cells with the new PCO Cells and replace the 4 Screws that hold them in place 5 Replace the Unit Cover and PCO Cells in the duct and secure with the 4 Brass Thumb Nuts 6 Place the Unit Power Cable...
Страница 12: ...WARRANTY INFORMATION...