9
ENGLISH
L1020502 Quick start iAV control valve (Revision F | 25.10.2022)
05
Installation
The installation procedure depends on the configuration of the system (see "Application" on page 3)� The LED on each compo-
nent indicates the active mode of the component (see the table on page 6)�
• Never pair components with multiple iAV Control valves at the same time� Complete zone by zone to prevent com-
ponents from being paired with an incorrect iAV Control valve (= different network)�
• After 15 minutes of inactivity, the iAV Control Valve automatically returns to User mode�
05.A
Installing components
Pairing procedure for one valve per zone (configurations A and B)
1� Only for systems with IQ unit:
a� Activate Installer mode by tapping INST on the IQ unit� The LED will flash green rapidly�
b� Tap the iAV Control valve 1x to pair it with the IQ unit so that the LED flashes green slowly� Tap again so the LED starts flash-
ing quickly� Underlying components can now be added in this zone�
Proceed to step 3�
2� Only for systems without an IQ unit:
Enter Installer mode by long pressing INST on the iAV Control valve until the LED starts flashing green quickly�
Proceed to step 3�
3� For all systems:
Add a control component (RF only if you are working without an IQ unit) by tapping 1x on the component to be paired� The LED
will start to flash green rapidly�
4� Repeat step 3 for the remaining control components�
5� Press INST on the iAV Control valve when all components in the zone are paired�
6� Only for systems with IQ unit:
Repeat steps 1b to 5 for any remaining zones�
7� Exit Installer mode by tapping INST on the IQ unit� The LED of each component in the system will stop flashing�
Please refer to the manual for the control components for more detailed information per component�
Pairing procedure for multiple valves per zone (configuration C and D)
1� Only for systems with IQ unit:
a� Activate Installer mode by tapping INST on the IQ unit� The LED will flash green rapidly�
b� Tap the iAV Control valve 1x to pair it with the IQ unit so that the LED flashes green slowly� Tap again so the LED starts flash-
ing quickly� Underlying components can now be added in this zone�
Proceed to step 3�
2� Only for systems without an IQ unit:
Activate Installer mode on the master iAV Control valve by long pressing INST on this iAV Control valve until the LED starts flash-
ing green quickly�
Proceed to step 3�
3� For all systems:
a� Add a control component (User control or Room sensor, RF only) by tapping 1x on the component to be paired� The LED will
start to flash green rapidly�
b� Set another iAV Control valve to be paired in slave mode by long pressing up () and down () simultaneously until the iAV Con-
trol valve slowly starts flashing red�
c� Tap INST of this slave iAV Control valve 1x to pair it with the network�
d� Repeat steps 3b and 3c for the remaining slave iAV Control valves in this zone�