background image

6

ENGLISH

L2000782 Installation guide for DucoBox Energy Comfort (Revision B.1 | 25.03.2020)

03

Regulations and safety 

instructions

a) The installer is responsible for 

installing and commissioning the 
unit.

b) Do not install this product in areas 

where the following are present or 
could occur:

• Excessively fatty atmosphere�

• Corrosive or flammable gases, liquids or fumes�

• Room air temperature above 40 °C or below -5 

°C�

• Relative humidity higher than 90% or outdoors�

• Obstacles that prevent access to or the removal 

of the fan unit�

• Bends in the ducts immediately upstream of the 

fan unit�

• The DucoBox Energy Comfort must not be 

connected to a (motorless) extractor hood/fan or 

tumble dryer�

c) General and specific safety 

instructions

Take care to ensure that the electrical supply is a 230 

V, single-phase earthed, 50/60 Hz, AC system� The 

device must be connected to an earthed and fused 

wall socket�

Secure the unit, preferably in an enclosed space, 

using the correct screws and mounting bracket, to 

a wall or using a mounting plinth on a floor with 

adequate load-bearing capacity�

The fan unit can only be used with the appropriate 

Duco accessories and user control(s)�

The installer must ensure that the fan unit is positio-

ned at least 3 m away from a flue pipe�

The unit must not be used in locations where it could 

be subjected to direct water spraying�

Certain situations may require the use of acoustic 

insulation materials�

Check that the unit is complete and undamaged 

when you take it out of the packaging� If you have any 

doubt about this, please contact Duco / your Duco 

sales outlet�

Electrical equipment should be handled with care

• Never touch the unit with wet hands�

• Never touch the device when barefoot�

Do not use the unit in the presence of flammable or 

volatile substances such as alcohol, insecticides, 

petrol etc�

Make sure that the electrical system to which the 

unit is connected complies with the stipulated 

conditions�

Do not expose the unit to the elements�

Do not place any objects on the unit�

Do not use the unit as an extractor for water heaters, 

heating systems, etc�

Ensure that the unit discharges into a single exhaust 

duct that is suitable and installed for the purpose 

and exhausts outdoors�

Ensure that the electrical circuit is not damaged�

Replace both filters in the unit every 6 months at 

most, this ensures that the unit is always protected 

against contamination and that the air being drawn 

in is healthy in all cases�

Always adhere to the safety instructions in the 

manual when installing the device� Failure to adhere 

to these safety instructions, warnings, notes and 

instructions could result in damage to the DucoBox 

Energy Comfort or in personal injury for which Duco 

NV cannot be held liable�

The DucoBox Energy Comfort requires to be installed 

in accordance with the general and locally applicable 

construction, safety and installation regulations of 

the local authority and other agencies�

Only an accredited installer is permitted to install, 

connect and commission the DucoBox Energy Com-

fort, as set out in this manual�

Keep the manual close to your unit�

Maintenance instructions must be followed closely in 

order to avoid damage and/or wear�

It is recommended that a maintenance contract be 

taken out to ensure the unit is regularly inspected 

and cleaned� The device must be fitted in a touch-sa-

fe manner� This means, among other things, that 

under normal operating conditions no-one can reach 

moving or electrically live parts of the fan without 

intending to do so for operations such as:

• Taking off the cover�

• Taking the motor module out of the fan after 

removing the cover�

• Disconnecting a duct or control valve from the 

connection opening during normal operation�

It must not be possible to touch the fan by hand� 

Ducting must therefore always be connected to the 

DucoBox Energy Comfort before it is put into opera-

tion� At least 900 mm of ducting must therefore be 

connected to the unit�

The DucoBox Energy Comfort satisfies the legal 

requirements imposed on electrical equipment�

Always ensure that before work begins, the device 

is isolated from the power supply by removing the 

power cord from the wall socket or by switching off 

the fuse� (Use a measuring instrument to check that 

this is actually the case!)

Use suitable / appropriate tools to work on the unit�

Use the unit only for applications for which it has 

been designed as stated in this manual�

The ventilation unit is required to operate continuo-

usly, i�e� the DucoBox Energy Comfort must never be 

switched off� (legal requirement under NBN D50-001)

Electronic components in the ventilation unit may 

be live� In the event of a fault, contact a professional 

installer and only have repairs carried out by expert 

personnel�

This unit is not intended for use by people (including 

children) with reduced physical, sensory or mental 

capabilities, or who lack experience or know-how, 

unless they are supervised or have been given 

instructions on the use of the unit by a person who is 

responsible for their safety� Children must be super-

vised to ensure that they do not play with the unit�

If the power cord is damaged, it must be replaced by 

the manufacturer, after-sales support or individuals 

with comparable qualifications in order to prevent 

any hazard�

The user is responsible for safely removing the 

ventilation unit at the end of its useful life, in accor-

dance with locally applicable laws or regulations� You 

can also take the unit to a collection point for used 

electrical equipment�

The unit is only suitable for housing construction and 

not for industrial use, such as swimming pools and 

saunas�

When handling electronics, always take measures to 

inhibit ESD, such as wearing an earthed wristband�

Modifications to the unit or to specifications stated in 

this document are not permitted�

Do not pull on the cord to remove the plug from the 

socket�

Always refer to the installer of your combustion 

appliance to establish whether there is a risk of flue 

gas ingress into the dwelling�

Check that the voltage shown on the nameplates 

matches the local mains voltage before connecting 

the device� You will find the nameplate on top of the 

unit�

Содержание DucoBox Energy Comfort 325

Страница 1: ...Installation guide ENGLISH DucoBox Energy Comfort L2000782 Revision B 1 25 03 2020...

Страница 2: ...17 08 A Pairing components 17 08 B Removing replacing components 18 08 C Tips 18 09 Air side calibration 19 09 A Pre setting vents 19 09 B Calibrating flow rates 20 09 C Verification 20 09 D Copy cali...

Страница 3: ...t 325 0000 4485 Optional accessories Product Item number Siphon flat Energy Eco 0000 4376 Communication Print 0000 4251 Humidity Box Sensor Energy Comfort 0000 4545 Mounting chair upright Energy Comfo...

Страница 4: ...heat exchanger This prevents the heat exchanger from freezing up If the imbalance is insufficient to prevent it from freezing up then the unit will be temporarily switched off Constant Flow The unit...

Страница 5: ...w at maximum flow rate 100 Pa 111 5W 111 5W 111 5W 111 5W Power at 50 Pa reference flow rate 47 9 W 47 9 W 47 9 W 47 9 W Sound power level Lwa 55 dB A 55 dB A 55 dB A 55 dB A Reference flow rate Qref...

Страница 6: ...stall connect and commission the DucoBox Energy Com fort as set out in this manual Keep the manual close to your unit Maintenance instructions must be followed closely in order to avoid damage and or...

Страница 7: ...connections 5 Wall mounting hanger bracket 6 Control unit with integrated user controls 7 Cap of the air filter 8 Cap of the air filter 9 Bypass valve 10 Power cable 230 VAC 11 Pressure sensor 12 Pre...

Страница 8: ...the op tion of allowing the Duco ventilation systems to commu nicate via ModBus and or ethernet ModBus integration enables them to be linked to a building management system Linking the Duco Ventilati...

Страница 9: ...Sensor or one of the connections on the optional Communi cation Print see page 8 05 A Cabling diagram Loosen the screws 1 Slide the cap forwards 2 Cut one or more or the specified pieces away from th...

Страница 10: ...m free field less through obstacles Maximum number of components Up to 25 wireless components in a single system 05 D Wired cabled communication Wired components can be daisy chained recommended This...

Страница 11: ...er months Take care to ensure that the air inlet is accessible for any cleaning that may be required A smaller cross sectional area bore can actually have a major detrimental impact on system performa...

Страница 12: ...ll ensure it is hanging level when doing so Ensure at the same time that the screws and plugs are suitable for the substrate and the weight of the unit 21 kg screws and plugs not included in the suppl...

Страница 13: ...ge duct of the DucoBox Energy Comfort and centrally measures the humidity of the air discharged from the house A DucoBox Energy Comfort contains a maximum of one box sensor Connecting the Humidity Box...

Страница 14: ...to ensure that the supply and exhaust vents are a minimum of 1 5 m van apart so they cannot come into contact It is preferable not to fit a vent right next to a wall in order to prevent soiling In ord...

Страница 15: ...the first time you will be asked to enter a few basic settings Navigate using the arrow keys and and confirm using enter General settings LEFT HAND RIGHT HAND setting The LEFT HAND RIGHT HAND setting...

Страница 16: ...hese steps you can proceed with the following steps in order to complete the installation Pairing control components with the DucoBox Energy Comfort Electrical system see page 17 DucoBox Energy Comfor...

Страница 17: ...run again if additional control components need to be paired at a later stage All previously paired components will be retained in the network LED indications Colour Blinking installation mode On con...

Страница 18: ...l buttons on a paired control The LED will flash green rapidly 5 sec 2 Press briefly twice on the button of the component to be replaced 2x OLD 3 Tap once on the button for the new component The latte...

Страница 19: ...mended for supply vents in order to prevent excessive noise from being genera ted For this reason it is recommended that the flow be split between different vents for higher flow rates SITUATION 1 One...

Страница 20: ...x Energy Comfort Depending on the user controller version this can also be done by pressing the lower and higher buttons on a paired user controller Adjust the flow rate so as to obtain the desired fl...

Страница 21: ...Make sure that all valves are adjusted identically presetting fine tuning for each installation 2 Activate advanced mode Scroll down to ADVANCED and press enter Enter the installer s code 9876 and pr...

Страница 22: ...be visible after that Operation The display on the DucoBox Energy Comfort is equipped with three 3 buttons up down and enter The arrow keys can be used to scroll through the menu If the display has n...

Страница 23: ...ng the arrow keys will enable changing the ventilation position Open the menu via enter The selected ventilation position on the unit is permanent indicated in purple in Controls until the user activa...

Страница 24: ...across the heat exchanger or not at all Fresh outdoor air will therefore not be heated up by warm stale indoor air This relatively cooler outdoor air entering the house will be used to reduce the tem...

Страница 25: ...dicates that advanced mode is active The menu will exit advanced mode after 30 minutes of inactivity or after restarting the DucoBox Energy Comfort Advanced mode can also be closed down manually using...

Страница 26: ...E VERSION for information In any communication with Duco you may be asked to state the software version of your DucoBox Energy Comfort Please keep this number to hand for any communication SERVICE COD...

Страница 27: ...products seller Keep the serial number of your product to hand The serial number is on the sticker at the top of the DucoBox Energy Comfort 12 Warranty All warranty conditions concerning the DucoBox...

Страница 28: ...Installed by L2000782 Document last modified on 25 03 2020 revision B 1...