DUCATI RADIO ROLLING CODE REMOTE CONTROLS 

Models:

6203ROL &  6203 / P = 2-channels radio remote  control  433,96Mhz

6204 & 6206 = 4-channels radio remote controls 433,96Mhz

Caution: 

Operate settings with gate in closed position.

A) To memorize a remote control code  in the control board of your automation:

1 -

 Press the P1  button on the electronic board

2 -

 release the button P1

3 -

 Press on the remote control, the button corresponding to the channel that you want to synchronize with the drive (you may need to hold the button 

for several seconds or even re-press it several times until the automation recognizes and stores the remote control code).

After saving the code, theelectronic board should issue a confirmation light (red LED).

The remote control has been programmed correctly.

Warning:

 Verify all the procedure with the manual of your automation because every model of electronic board may have variants or specific functions.

4 -

 To operate the automation, press the button on the remote control previously synchronized.

Attention: Electronic boards of automation have a limited memory capacity. (If you need more memory available is a 4-channel external receiver model 

Rixy 6040 / 6040Rol)

B) To clear the memory of the electronic board. (Total loss of memory)

In the case in which the memory card is full or in case of need to erase and reprogram a code of a remote control will need to follow this procedure and 

reset the memory of the automation.

Caution: 

This operation will erase all the card automation radio control codes previously stored. After this you will need to memorize codes again.

- Press and hold the button P1 on the PCB until the (red)  LED emits a bright to confirmamemory has been ereased

2 - 

Release  P1

All radio control codes have been erased. To re-synchronize the remote controls active follow the operations of point A from 1 to 4.

Warning: Verify all the procedure with the manual of your automation because every model of electronic board may have variants or specific functions.

QUICK SOLUTION OF PROBLEMS

in any case, make sure the electronic board of your device is properly powered . Control the control fuse.

If only one of the remote control does not work:

1)

 verify that the remote control is compatible with automation

2)

 replace the battery of the remote control (although LED is lit). A low battery level may compromise the flow rate and / or the transmission itself.

3)

 it is possible that the electronic board is full. Delete all the codes and re-enter the codes in use (up to control board capacity)

If only one of the remote control does not work:

see as above points 1) 2) 3) alternatively

This may be a problem with the receiver automation. to test this, try if the device  works using a wired control (key switch), see START contact on your 

electronic board. 

Call the after sales  assistance.

6203 ROL

6204

6206

DUCATI

DUCATI

H O M E

automation

The undersigned, declares under his sole responsibility, that the following 

products 6203

conform with the requirements of the following EC directives: 

98/37/EC  (89/392/EEC  amended);  DIRECTIVE  98/37/EC  OF  THE  EU

-

ROPEAN PARLIAMENT AND COUNCIL of 22 June 1998 regarding the 

approximation of member state legislation relating to machinery.

As established in directive 98/37/EC, the above-mentioned product may 

not be started up unless the machine in which the product is incorporated 

has been identified and declared as conforming to directive 98/37/EC.

The product also complies with the requirements 

R&TTE -RADIO

EN301489-3V.1.4.1  

EN 300 220-2V.2.1.2 

use in CENELEC listed states

FCC- USA Federal telecommunication commission

FCC ID: OLS137925764*  

Washington laboratories tested

* only for PULT6203

PULT 6203:     CE0681 
PULT 6204:     CE0678 

DHA Srl

 ITALY

www.ducatihome.it

[email protected]

D U C O   r o l l i n g   c o d e

Отзывы: