9 Function configuration (Communication setting)
9.1
Wiegand option set
Following is the communication frame for wiegand option setting. Since it is saved in flash
memory after the first setting, the reader does not need to be set again.
(115,200bps, 8 data, no parity, 1 stop bit)
STX
LENH
LENL
CMD
DATA
LRC
0x02
0x00
0x02
0xE0
DATA[0]
LENL ^ CMD ^ DATA[0]
( ^ : exclusive oring)
9.2
LED option set
Following is the communication frame for LED color setting. Since it is saved in flash memory
after the first setting, the reader does not need to be set again.
(115,200bps, 8 data, no parity, 1 stop bit)
STX
LENH
LENL
CMD
DATA[0]
LRC
0x02
0x00
0x02
0xE1
0- BLUE LED
ON
1- RED LED ON
LENL ^ CMD ^
DATA[0]
DATA[0]
State
Description
Bit7~3
RFU
RFU
Bit2
0
Parity Send(34 or 66bit) depend on ID bytes(No.1)
1
Parity Omit(32 or 64bit) depend on ID bytes(No.1)
Bit1
0
Forward ID byte order
1
Reverse ID byte order
Bit0
0
Not Read MIFARE card in Security Mode
(Security Mode : SAM authentication for FeliCa,
Reader enters security mode when SAM exists when boot.)
1
Read MIFARE card in Security Mode