2-6
Operation procedures
Loading a plate
CAUTION:
This processor is built for single plate load only. Do not try to load two parallel plates.
1.
Place the plate with the Mylar facing down on
the feed table (polymer facing up).
Three sets of indicators are engraved into the
feed table:
-
640 mm (25.2")
-
900 mm (35.4")
-
1067 mm (42")
2.
Position the plate between the set of
indicators which match the plate width.
NOTE:
Ensure the plate is vertically
aligned with both the top and the
bottom indicator.
CAUTION:
Allowed min./max. sizes
of width and length are
W: 600 mm - 1067 mm (23.6" - 42")
L : 450 mm - 1600 mm (17.7" - 63")
3.
Gently push the plate into the entrance slot so
that the front edge of the plate rests on the 2
front stops.
If positioned correctly the stack light will
change from green to blue.
Release the plate. The stack light should
remain blue. If it changes to green, gently
reposition the front edge of the plate until the
stack light turns blue, ensuring that the plate
remains correctly positioned between the
indicators.
CAUTION:
Do not put any force or
pressure on the plate to achieve the
blue light signal. Gently reposition the
plate if the blue light does not appear.
4.
When the stack light is blue, press the 'Start'
button on the control panel.
5.
The processor will now automatically load the
plate and start processing.
Operation Manual
|
Cyrel FAST 2000TD
January, 2020
Содержание Cyrel FAST 2000TD
Страница 37: ...Operation procedures 2 19 Blank January 2020 Operation Manual Cyrel FAST 2000TD...
Страница 38: ...3 0 Panel overview Panel overview Operation Manual Cyrel FAST 2000TD January 2020...
Страница 49: ...Control panel 3 11 Menu diagram January 2020 Operation Manual Cyrel FAST 2000TD...
Страница 86: ...Operation Manual Cyrel FAST 2000TD January 2020...
Страница 106: ...B 14 Appendix B Blank Operation Manual Cyrel FAST 2000TD January 2020...