2-4
Operation procedures
Shutting down
CAUTION:
Always follow the cooling down procedure described below before switching off power
on the main switch!
Procedure
1.
Press the 'ON/OFF' button.
2.
Press the 'Heating - Power OFF' button to
deactivate heating of the heated roller and the
catox.
3.
Press the 'Home' button to return to home
view.
4.
While cooling down, a cooling-down message
will be displayed.
NOTE:
It will take approx. 40 min. for
the heated roller and the catox system
to cool down.
CAUTION:
Do not turn off the external
exhaust system to the processor
during the cooling down period.
5.
When the message disappears it is safe to
switch off .. .
-
the chiller,
-
the external exhaust system,
-
the main power supply,
-
the compressed air supply.