Communication Features 

The  SLICE  Distributor  supports  the  industry-standard  Ethernet  10/100BaseT/Tx 
communication  method.    Communication  is  enabled  after  the  power-up  sequence  has 
completed.  (See Appendix C for information on the network parameters of your equipment.) 

SLICE System Connectors 

These 4 connectors are identical and support power, start, event, status 
and  USB  communication  signals  for  the  DAS.    One  SLICE  connector 
supports up to 3 SLICE stacks, with a maximum of 8 SLICE Bridges per 
stack,  in  any  combination  of  SLICE  MICRO  or  NANO.    SLICE  MICRO 
Accel  and  ARS  units  can  be  used  in  place  of  a  Bridge  and  the  SLICE 
NANO Battery can be used with any SLICE NANO stack. 

 

 

 

 

 

 

 

 

 

 

 

= 54 ch 

(maximum) 

(

Original Base

 MICRO and/or NANO; SLICE NANO Battery optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

= 72 ch 

(maximum) 

(MICRO and/or NANO 

Base+

; SLICE NANO Battery optional)

 

 

Maximum current for all 4 SLICE System connectors combined is 10 A with a maximum of 
4 A  per  connector.    Carefully  calculate  your  expected  maximum  power  consumption  to 
ensure  compliance  with  power  limits.    (Please  see  page  9  for  information  on  power 
requirements.) 

 

Содержание SLICE Distributor

Страница 1: ...13000 30030 MAN Rev 3 Diversified Technical Systems Inc All Rights Reserved SLICE Distributor User s Manual February 2018...

Страница 2: ...6 SLICE System Connectors 6 Basic Care and Handling 7 Shock Rating 7 Mounting Considerations 7 Thermal Considerations 7 Power Management 8 Maximum Power Consumption 8 Maximum Input Power 8 Maximum Out...

Страница 3: ...rience to help via telephone e mail or on site visits The best way to contact a DTS support engineer is to submit a request through the DTS Help Center web portal support dtsweb com You must be regist...

Страница 4: ...vercurrent protection power input polarity protection LED indicator provides status information Integral mounting holes Ideal for embedded and in dummy high channel count applications SLICEDistributor...

Страница 5: ...s overvoltage or overcurrent condition is present If unit is on cycle power to reset On Off Pushbutton Switch A momentary pushbutton switch is used for on off control When the unit is on LED is blue a...

Страница 6: ...for the DAS One SLICE connector supports up to 3 SLICE stacks with a maximum of 8 SLICE Bridges per stack in any combination of SLICE MICRO or NANO SLICE MICRO Accel and ARS units can be used in plac...

Страница 7: ...r repair Shock Rating The SLICE Distributor is rated for 500 g 4 ms half sine duration in all axes Mounting Considerations The unit should be securely bolted to the test article or dynamic testing dev...

Страница 8: ...utput power available per SLICE system connector is 12 V at 4 A The maximum output current available via the AUX connector is 2 5 A input VDC output VDC Charging Powering Attached Equipment When suffi...

Страница 9: ...est fixture to confirm resistance readings of 1 ohm TroubleshootingBasics Begin troubleshooting by checking the operational state of the SLICE Distributor alone DTS suggests always using the connectio...

Страница 10: ...lth If the status LED is red this can mean input voltage is too high or overcurrent condition is present You will need to correct this before proceeding 4 Connect the Ethernet comm cable from the SYS...

Страница 11: ...to pin 2 3 Event isolated bi directional contact closure to pin 2 4 Recording status high recording 4 Recording status high recording 5 Reserved 5 ON status 6 VDC input from ext battery Ground 6 Groun...

Страница 12: ...into the connector Pin Function 1 ON bi directional contact closure input to ground 2 START bi directional contact closure input to ground 3 EVENT bi directional contact closure input to ground 4 Stat...

Страница 13: ...Cable SLICE Distributor to DDX cable SDX 1 m 13000 30440 SLICE Distributor AUX Connector Assy 13000 30441 SLICE Distributor AUX Cable Assy 5 m pigtail term 13000 30450 SLICE Distributor SYS Connector...

Страница 14: ...0 SD00200 SD00300 x 101 for S Ns SD00101 SD00201 SD00301 x 2 99 for S Ns SD00102 SD00399 Netmask 255 255 252 0 The calibration data for your equipment identifies the IP address as shipped from the fac...

Страница 15: ...urrent IP address Use compatibility mode with Internet Explorer Enter the desired IP address and or netmask into the available fields and click Apply If the IP address is valid the page will show succ...

Страница 16: ...number of stacks was 4 now 3 referenced in second paragraph and illustrations on page 6 Updated network info to refer to Appendix C Rev 3 27 Feb 2017 EK Added Appendix C and page 8 footnote Updated a...

Отзывы: