SAFETY INFORMATION

This engine generator set has been designed and
manufactured to allow safe, reliable performance.
Poor maintenance, improper or careless use can
result in potential deadly hazards;  from electrical
shock, exhaust gas asphyxiation, or fire.  Please read
all safety instructions carefully before installation or
use.  Keep these instructions handy for future
reference.  Take special note and follow all warnings
on the unit labels and in the manuals.

ANSI SAFETY DEFINITIONS

************************************************************
DANGER:

DANGER indicates an imminently hazardous
situation which, if not avoided, will result in death or
serious injury. This signal word is to be limited to the
most extreme situations.

***********************************************************

************************************************************
WARNING:
 WARNING indicates a potentially hazardous situation

which, if not avoided, could result in death or serious
injury.

***********************************************************

***********************************************************
CAUTION:
CAUTION indicates a potentially hazardous situation

which, if not avoided, may result in minor or moderate
injury. It may also be used to alert against unsafe
practices.

************************************************************
NOTE:

CAUTION is also used on the unit labels and in this

manual to indicate a situation that could result in
serious damage or destruction of the equipment and
possible personal injury.

1. ELECTRIC SHOCK -  The output voltage present in this

equipment can cause a fatal electric shock. This
equipment must be operated by a responsible
person.

a.

Do not allow anyone to operate the generator
without proper instruction.

b.

Guard against electric shock.

c.

Avoid contact with live terminals or receptacles.

d.

Use extreme care if operating this unit in rain or
snow.

e.

Use only three-prong grounded receptacles and
extension cords.

f.

Be sure the unit is properly grounded to an
external ground rod driven into the earth.

2. FIRE HAZARD - Natural gas and L.P. present a hazard

of possible explosion and/or fire.

a.

Do not refuel when the engine is running or hot.
Allow the engine to cool at least two minutes

before refueling.

b.

Keep fuel containers out of reach of children.

c.

Do not smoke or use open flame near the
generator set or fuel tank.

d.

Keep a fire extinguisher nearby and know its
proper use.  Fire extinguishers rated ABC by
NFPA are appropriate.

e.

Store fuel only in an approved container, and only
in a well-ventilated area.

f.

Follow local codes for closeness to combustible
material.

3. DEADLY EXHAUST GAS - Exhaust fumes from any

gasoline engine contain carbon monoxide, an
invisible, odorless and deadly gas that must be mixed
with fresh air.

a.

Operate only in well ventilated areas.

b.

Never operate indoors.

c.

Never operate the unit in such a way as to allow
exhaust gases to seep back into closed rooms
(i.e. through windows, walls or floors).

4. NOISE HAZARD - Excessive noise is not only tiring,

but continual exposure can lead to loss of hearing.

a.

Use hearing protection equipment when working
around this equipment for long periods of time.

b.

Keep your neighbors in mind when permanently
installing this equipment.

5. CLEANLINESS - Keep the generator and surrounding

area clean.

a.

Remove all grease, ice, snow or materials that
create slippery conditions around the unit.

b.

Remove any rags or other material that could
create potential fire hazards.

c.

Carefully clean up any gas or oil spills before
starting the unit.

d.

Never allow leaves or other flammable material
to build up around the engine intake or exhaust
area.

6. SERVICING EQUIPMENT - All service, including the

installation or replacement of service parts, should be
performed only by a qualified technician.

a.

Use only factory approved repair parts.

b.

Do not work on this equipment when fatigued.

c.

Never remove the protective guards, cover, or
receptacle panels while the engine is running.

d.

Use extreme caution when working on electrical
components.  High output voltages from this
equipment can cause serious injury or death.

e.

Always avoid hot mufflers, exhaust manifolds,
and engine parts.  They all can cause severe
burns instantly.

f.

Installing a generator set is not a “do-it-yourself”
project. Consult a qualified, licensed electrician
or contractor.  The installation must comply
with all national, state, and local codes.

Содержание WINCO PSS15B2W/A

Страница 1: ...PACKAGED STANDBY SYSTEM PSS15B2W A INSTALLATION AND OPERATORS MANUAL Engine Generator Set...

Страница 2: ...rication 6 Battery Installation 6 Connecting Battery Charger 6 TRANSFER SWITCH INSTALLATION 6 AC Electrical Connections 7 DC Electrical Connections 8 INITIAL START UP 8 TROUBLESHOOTING INFORMATION 9 W...

Страница 3: ...ut of reach of children c Do not smoke or use open flame near the generator set or fuel tank d Keep a fire extinguisher nearby and know its proper use Fire extinguishers rated ABC by NFPA are appropri...

Страница 4: ...UNIT LINE SIDE GENERATOR CONTACTOR SIDE CONTACTOR PSS15B2W A 100AMPS 60 AMPS UL Automatic Transfer Switch Sizes UNIT LINE SIDE GENERATOR CONTACTOR SIDE CONTACTOR PSS15B2W A 100 AMPS 100 AMPS 200 AMPS...

Страница 5: ...rrier for claim procedures Be sure to retain the packaging material for carrier inspection Concealed Damage is understood to mean damage to the contents of a package which is not evident at the time o...

Страница 6: ...stays clean WARNING FIRE HAZARD DO NOT OVERTIGHTEN THE FUEL LINE THIS IS A TAPERED FITTING OVERTIGHTENING WILL CAUSE THE FITTING TO CRACK AND LEAK FUEL For all vapor fuel systems the delivery pressure...

Страница 7: ...n inches of water column The second is with a pressure gauge calibrated in ounces per square inch Reference numbers 1 through 3 in the block diagrams above are system parts supplied by customer Refere...

Страница 8: ...battery terminal is connected to the negative cable ground from the engine generator assembly All connections must be clean and tight Check the electrolyte fluid in the battery periodically to be sure...

Страница 9: ...ion panel should contain your only neutral to ground bond All power leads from the generator to the A T S must be sized to handle rated generator output amperage at a minimum the type of wire you use...

Страница 10: ...anded wire should be used These wires will be labeled Bat and Start The control wires will be connected as follows in the generator control terminal box ATS Panel Generator Control Panel Start 1 to Wi...

Страница 11: ...s you will have to fail the incoming line power to the A T S panel All the loads connected to the A T S should now be dead The engine generator set will go into a 3 to 10 second start delay At the end...

Страница 12: ...be 3600 RPM 9 AC short on output leads PREVENTIVE MAINTENANCE Reasonable care in preventive maintenance will insure high reliability and a long life for the engine generator set and the Automatic Tra...

Страница 13: ...PAGE 11 4190 00 60706 169 AC AND DC GENERATOR WIRING DIAGRAM...

Страница 14: ...PAGE 12 60706 169 4190 00 AC AND DC GENERATOR SCHEMATIC...

Страница 15: ...PAGE 13 4190 00 60706 169 GENERATOR LAYOUT...