network broadcasting system
8
5.2 Instruction for the Terminal Function Setting
As the Method 1 in 5.1 above, it ensures host computer/ computer and the terminal in the same network
segment, and input the IP address of the terminal on IE browser to get into the following page, and then click
“Public Address” for a further function setting to the terminal (as the picture below):
1. Off-line schedule function: Enable mode and disable mode are optional, to ensure that there is no switch to
100V state, according to their own needs to start offline schedule point function. When you need to start the
function, select "Enable "option and press the" Submit "button; instead, select" Disable "option.
2. 100V constant voltage backup function: a. Without network; if chose “Enable” before, when the network
play is abnormal or the terminal drops, it will switch to 100V audio signal automatically; if chose “Disable”
before, when the network is abnormal, it will not switch to 100V audio signal. b. Without Power; whether
chose “Enable” or “Disable” before, it will switch to 100V audio signal automatically.
3. On-demand panel terminal function: to ensure that there is no switch to 100V state, select "fixed" option for
the terminal being fixed for the on-demand panel terminal, and when select the "dynamic" option, plug in the
on-demand panel for the on-demand panel terminal; not inserted for the ordinary playback terminal.
4. Local network preference: Three priority modes. to ensure that there is no switch to 100V state, when the
"local" option is selected, the local source is output first, and the "network" option is the same. When
"mixed" is selected, both local and network are output at the same time.
5.
Microphone type selection: According to their own needs to select the condenser or dynamic type to ensure