* Public Address System Intelligent Public Address System
12
reminds you can power it off safely, then you can use the key switch to power it off.
2—4.9 In case that the main processor of the system breaks down (system halted-unable to move the
cursor-unable to operate the screen button), all broadcasting partition will automatically switch to the
prior input sound source, and enter into the gate state. Then you can use the prior microphone or insert
the
external sound sources
into the vacant inlet of the
prior input module
temporarily to support the
system operation (the priority needs to be noted); at the same time, full alarm manual button is still
effective.
2
—
5
Restrictions of minimum system
The minimum system has already possessed basic functions of a public broadcast, but it does not have fire
control, telephone, remote call ports, so it can not be linked to those systems;
The partition functions are not complete: partition alarm giving, call, different programs publishing are
unavailable. But partition gating is still available.