SIP Intercom System
9
/ 47
6)
Private access code to open the door.
Enable for local authentication, and set private access code. Input the access code directly under
standby mode to open the door. In this way, the door log will record corresponding card number and
user name.
7)
Active URL control command to open the door.
URL is “http://user:pwd@host/cgi-bin/ConfigManApp.com?key=F_LOCK&code=openCode”
a.
User and pwd is Web the user name and password.
b.
“openCode” is the remote control code to open the door.
Example: “http://admin:[email protected]/cgi-bin/ConfigManApp.com?key=*”
If access code is input correctly, the device will play sirens sound to prompt access control and the
remote user, while input error by low-frequency short chirp.
Password input successfully followed by high-frequency sirens sound, while input error is followed by
high-frequency short chirp.
When door has been opened, the device will play sirens sound to prompt.
IV.
Page settings
1.
Browser configuration
When the device and your computer are successfully connected to the network, enter the IP address of
the device on the browser as http://xxx.xxx.xxx.xxx/ and you can see the login interface of the web page
management.
Enter the user name and password and click the [logon] button to enter the settings screen.
2.
Password Configuration
There are two levels of access: root level and general level. A user with root level access can
browse and set all configuration parameters, while a user with general level can set all configuration
parameters except server parameters for SIP.