OWNER'S MANUAL
AN-RMP1 Series - PIR detector for indoor
DSE srl - Digital Surveillance Equipment - www.dse.eu
AN-RMP1
Infrared Detector
Product description
The AN-RMP1 volumetric sensors are used to detect the intrusion of people in an environment
open to an alarm contact. They are used in conjunction with a VCR or DVR burglar alarm
systems.
Opening the box
The front cover of the sensor must be removed for the installation and configuration. It is
necessary to unscrew the retaining screw and uncover the sensor in order to access to the
motherboard and start with the configuration. The retaining screw should not be unscrewed
completely, just loosen it a few turns. Once you arrived at the sensor board it is possible to
remove it from the base by unscrewing the single screw which holds it in its place, to facilitate the
connection of the wires in the terminal block.
Mounting and positioning
The sensor is fixed to the wall. The installation height should be around 2.2 / 2.4 meters. To
obtain maximum performance, it is necessary to avoid installing the sensor near to the following
sources of interference: reflective surfaces, direct air flows, vents, fans, windows, vapor, infrared
light sources and objects causing temperature changes such as heaters, refrigerators or ovens.
The base of the sensor is equipped with some knockouts zones to allow the passage of cables
inside.
operation
The AN-RMP1 sensor bases its operation on a dual element PIR (passive infrared) that detects
the temperature present in an environment by means of a radial pattern of infrared rays. The
temperature change between adjacent rays, generated by an intrusion, causes the opening of the
alarm contact for 2 seconds.
coverage
The sensor covers the area in front of him according to the following diagram.
view from above
seen from the side
Connections and wiring
On the sensor board to which a terminal block is installed to connect
the power supply,
eventually
the anti
tamper (TAMPER) and the alarm line. 12VDC - Connect the 12VDC power supply (+ and -)
coming from a burglar alarm control panel or from a feeder.
TAMPER - NC contact that opens in case of sensor tampering. To be connected to the tamper
line of the control panel.
RELAY - Contact NV which opens for about two seconds on alarm. Connect to a central area of
the burglar alarm or the entrance of a DVR or other device.
Settings
The sensor is equipped with different adjustments placed on the board