![DSC PowerSeries SCW9045-433 v1.0 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/dsc/powerseries-scw9045-433-v1-0/powerseries-scw9045-433-v1-0_installation-and-wiring-manual_2534745022.webp)
18
[030] Zone Loop Response Options
[101]-[134] Zone Attributes: Options 10-13 are reserved for Future Use.
Zone Attribute Defaults
Opt
Def.
ON
OFF
1
Zone 33 is Fast Loop Response
9
Zone 33 is Normal Loop Response
2
Zone 34 is Fast Loop Response
9
Zone 34 is Normal Loop Response
3-8
Future Use
9
Attribute:
1
2
3
4
5
6
7
8
9
14
15
16
ON Audible Steady Chime Bypass Force* Swing Tx. Delay Cross Zn
Future
Use
Future
Use
Future
Use
Future
Use
OFF
Silent
Pulsed
No
No
No
No
No
No
Zone Type:
00 Null Zone
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
01 Delay 1
ON
ON
ON
ON
ON
ON
OFF
OFF
02 Delay 2
ON
ON
ON
ON
ON
ON
OFF
OFF
03 Instant
ON
ON
ON
ON
OFF
ON
OFF
OFF
04 Interior
ON
ON
OFF
ON
OFF
ON
OFF
OFF
05 Interior Stay/Away
ON
ON
OFF
ON
ON
ON
OFF
OFF
06 Delayed Stay/Away
ON
ON
OFF
ON
ON
ON
OFF
OFF
07 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
08 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
09 24hr Superv. (Hardwired)
OFF
ON
OFF
OFF
ON
ON
OFF
OFF
10 24hr Superv. Buzzer
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
11 24hr Burglary
ON
ON
OFF
ON
OFF
ON
OFF
OFF
12 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
13 24hr Gas
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
14 24hr Heat
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
15 24hr Medical
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
16 24hr Panic
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
17 24hr Emergency
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
18 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
19 24hr Water
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
20 24hr Freeze
ON
ON
OFF
OFF
OFF
ON
OFF
OFF
21 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
22 Momentary Keyswitch Arm
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
23 Maintained Keyswitch (Hardwired)
OFF
OFF
OFF
OFF
ON
OFF
OFF
OFF
24 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
25 Interior Delay
ON
ON
OFF
ON
OFF
OFF
OFF
OFF
26 24hr Non-alarm
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
27-31 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
32 Instant Stay/Away
ON
ON
OFF
ON
OFF
ON
OFF
OFF
33 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
34 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
35 Future Use
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
36 24hr Non-latching Tamper
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
37 Night Zone
ON
ON
OFF
ON
ON
ON
OFF
OFF
87 Delay 24hr Fire (Wireless)
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
88 Stand. 24hr Fire (Wireless)
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
89 Auto-verified Fire (Wireless)
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
Содержание PowerSeries SCW9045-433 v1.0
Страница 2: ......