[005] System Times
[009] I/O Programming
[012] Keypad Lockout Options
[013] First System Options
Valid entries for Entry Delay are between 030-255.
030
I___I___I___I
Entry Delay 1
Valid entries are 001 - 255 seconds, 000 also sets time to 255 seconds
045
I___I___I___I
Entry Delay 2
Valid entries are 001 - 255 seconds, 000 also sets time to 255 seconds
060
I___I___I___I
Exit Delay
Valid entries are 001 - 255 seconds, 000 also sets time to 255 seconds
005
I___I___I___I
Bell Cut-off
Valid entries are 001 - 255 minutes, 000 also sets time to 1 minute
[006] Installer’s Code
[007] Master Code
Default
Default
5555
I_______I_______I_______I_______I
1234
I_______I_______I_______I_______I
Programmable Output Options
00
Null PGM (Not Used)
01
Residential Burglary and Fire Bell Output
02-04
Future Use
05
System Armed Status
06
Ready To Arm
07
Keypad Buzzer Follower
08
Courtesy Pulse
09
System Trouble Output (with Trouble Options)
10
System Event Output (with Event Options)
11
System Tamper (all sources: zones, keypad)
12
TLM and Alarm
13-16
Future Use
17
Away Armed Status
18
Stay Armed Status
19
Command Output #1 ([ ][7][1])
20
Command Output #2 ([ ][7][2])
Program Zone Definition Attributes in Sections [133-134], Program PGM Option Attributes in sections [501] - [502].
Default
10
I_______I_______I
I/O Type (Zone 33, PGM 1)
Enter Zone Definition or PGM Definition
01
I_______I_______I
I/O Type (Zone 34, PGM 2)
Enter Zone Definition or PGM Definition
If Keypad Lockout is active, the panel cannot be disarmed with a keyswitch.
Default
000
I_______I_______I______I
Number of Invalid Codes Before Lockout (Valid entries are 000-255)
000
I_______I_______I______I
Lockout Duration (in minutes)
(Valid entries are 000-255)
Opt
Def.
ON
OFF
1
9
Hardwired Zone 33 Input Enabled
PGM1 Output Enabled
2
Hardwired Zone 34 Input Enabled
9
PGM2 Output Enabled
3-5
Future Use
9
6
9
Audible Exit Fault Enabled
Audible Exit Fault Disabled
7
9
Event Buffer follows Swinger Shutdown
Event Buffer Logs Past Shutdown
8
Temporal Three Fire Signal Enabled
9
Standard Pulsed Fire Signal