Section 5: Operation
11
[ ][2] – Trouble Display
Refer to
Section 9: Testing & Troubleshooting
, for troubleshooting assistance and a detailed description of all trouble conditions.
[ ][3] – Alarm Memory Display
Pressing the scroll
<>
keys will display an “Alarms in Memory” message if an alarm occurred during the last armed period. Pressing
[ ][3]
will
display the message
“Scroll to view Alarms”
. Scrolling will display the zones that went into alarm. To clear the Memory, arm then disarm the
system.
[ ][4] – Door Chime Enable/Disable
Press
[ ][4]
. The keypad will emit 3 rapid beeps to indicate that the door chime feature is now enabled and a steady 2-second tone if it is now dis-
abled. The same function can be performed by pressing and holding the Chime function button for 2 seconds.
[ ][5] – Program User Codes
The following table identifies available user codes:
Programming User Codes:
Press
[ ][5]
followed by the Master Code. The keypad will display the first user (user 01) and include the letter ‘P’ if the user code is pro-
grammed. Scroll to the appropriate user and press the
[ ]
key to program the user (or enter the 2-digit user number). Enter a new 4 or 6-digit user
code or press
[ ]
to delete the user code. After the user code is programmed or deleted, scroll to another user or press
[#]
to exit.
Programming User Attributes:
Press
[ ][5]
followed by the Master Code or Supervisor Code. Press
[9]
followed by the 2-digit user to change to the user attributes.
[1]
Supervisor’s Code
This attribute makes the code valid when entering the
[ ][5]
User Code Programming section and
[ ][6]
User
Functions. Note, these codes can only program codes which have equal or lesser attributes. This attribute will also
allow this user to create bypass groups if an access code is required to enter into
[ ][1]
Bypassing.
[2]
Duress Code
Duress codes are standard user codes that will transmit the Duress Alarm Reporting Code whenever the code is
entered to perform any function on the system.
[3]
User can manually bypass zones if Bypassing requires an access code.
[4]-[6]
Future Use
[7]
The panel will squawk the bell output when the user arms or disarms when in Away Armed mode.
[8]
One-time Use Code
The One-time-use Code allows unlimited arming but only permits a single disarming once a day.
The Disarm function is restored at midnight.
To change the user attributes, press the number corresponding to the attribute or scroll to the desired attribute and press
[ ]
. When the correct
attributes are assigned to the user, press
[#]
to exit. To change the user attributes for another user, press
[9]
followed by the 2-digit user number.
When finished, press
[#]
to exit.
Code
Type
Function
[01] – [16]
[40]
General User Codes
Master Code
Arm, disarm, attribute functions
All functions, arm, disarm, program user codes
These attributes affect the operation of wireless keys.
Wireless key numbers (01-16) correspond with User access codes (01-16).
Duress codes are not valid when entering [*][5], [*][6] or [*][8] sections and will transmit a duress alarm.
Duplicate codes and codes that are +/- 1 of an existing code can not be programmed.
Содержание PowerSeries SCW9045-433 v1.0
Страница 2: ......
Страница 58: ...NOTES...