Force Arm Enable –

 This attribute determines whether

or not the system can be armed while a zone is violated.
At the end of the exit delay, if this type of zone is violated,
it will be ignored by the panel. Once the zone is secured,
it will be monitored by the system. This zone attribute, for
example, will allow the user to arm the system with the
garage door open. Later, when the door is closed, it will
be armed along with the rest of the system. Do not pro-
gram this attribute for 24Hr zones.

Swinger Shutdown Enable –

 This attribute determines

whether or not the panel will shut down the communica-
tor and bell for a zone once its swinger limit has been
reached (see section 5.19 

“Swinger Shutdown” on page

24)

Transmission Delay Enable –

 This attribute determines

whether or not the panel will delay communicating the
alarm reporting code for the programmed Transmission
Delay Period (see section 5.15 

“Transmission Delay” on

page 23).

Wireless Zone –

 This attribute determines which zones

are to have wireless devices. This allows the panel to
generate a low battery trouble and zone supervisories for
the wireless zones.

NOTE: Any zone with the wireless attribute enabled will not
cause an alarm for a fault condition when armed (or any time
for 24-hour zones).

Zone Attributes  . . . . . . . . . . .  Sections [101] - [108]: [1] - [8]

5.4

Assigning Keypad Zones

“Z” keypads have zone inputs to which devices—such as
door contacts—can be connected. (See section 2.11 

“Keypad

Zones” on page 6 for wiring information.)
Once the keypad zones are installed, assign the zone in pro-
gramming section [020] 

Keypad Zone Assignments

.

Enter the 2 digit zone designated for each keypad (address)
from 01-08.

Keypad Zone Assignments . . . . . . . . . . . . . . . . . . . . . .  [020]

5.5

Communicator – Dialing

If the 

Communicator Disable

 option is selected, the panel

will not attempt to call central station. If communication is
enabled, the panel will attempt to call central station when an
event with a valid reporting code occurs (See section 5.8
“Communicator – Reporting Codes” on page 17
). 
The 

Communicator Call Direction

 options are used to select

which telephone number the panel will dial when an event
occurs.
If the 

DTMF Dialing

 option is enabled, the panel will dial using

DTMF (touch tone). If the 

Switch to Pulse Dial

 option is

enabled, the panel will switch to pulse dialing on the fifth
attempt to call the central station. When this option is dis-
abled, the panel will always dial using DTMF. If 

DTMF Dialing

is disabled, the panel will always pulse dial.
When the 

Force Dialing

 option is enabled, the panel will dial

out regardless of the presence of dial tone. Each dialing
attempt will follow this pattern: 
a)

the panel pick up the telephone line and search for dial

tone for 5 seconds 

b)

if no dial tone is found, the panel will hang up and wait for

20 seconds

c)

the panel will pick up the telephone line again and search
for a dial tone for 5 seconds

d)

the panel will then dial regardless of the presence of dial
tone

If there is no initial handshake recognized within 40 seconds
the panel will then hang up the line. 
If the 

Force Dialing

 option is disabled, each attempt will still

follow the above pattern, except that the panel will not dial in
step d if no dial tone is detected.
The 

Delay Between Dialing Attempts

 timer adds a delay

before the next call is dialed.
If the 

Anti-Jam Feature

 is enabled, each dialing attempt will

work as follows: if there is no dial tone present on the initial
dial tone search, the panel will hang up the phone for 90ms,
and then perform another dial tone search. If no dial tone is
detected, the panel will hang up for 20 seconds, then perform
another five second dial tone search. The panel will then force
dial if force dialing is enabled. The whole sequence counts as
one dialing attempt.

Maximum Dialing Attempts

 determines the maximum num-

ber of attempts the panel will make to send a signal to the
central station before indicating a Failure to Communicate
(FTC) trouble condition. The maximum number of dialing
attempts that can be programmed is 15. 
The 

3rd Telephone Number

 can be used to back up the 1st

in the event of an FTC. (see section 5.7 

“Communicator – Tele-

phone Numbers” on page 17). If a later communication
attempt is successful, the FTC reporting code(s) programmed
in section [351] will be transmitted along with the unreported
events from an earlier unsuccessful communication.
When 

Bell on FTC when Armed

 is enabled in programming

section [702], option [8], an FTC during the armed period will
sound an Audible Alarm for the length of Bell time-out or until
the system is disarmed. If 

FTC Trouble Only when Armed

 is

enabled, only the keypad buzzer will sound trouble beeps
every 10 seconds until a key is pressed.

Post Dial Wait for Handshake

 determines the amount of time

the panel will wait for a valid handshake from the receiver. If
the panel does not hear the handshake it will consider the call
a failed attempt, hang up and try again.
The 

Pulse Dialing Make/Break Ratio

 option can change the

Make/Break ratio to 33/67 from the North American ratio of 40/
60. 
With 

ID Tone Enabled

 the panel will pulse a tone on the tele-

phone line to indicate that the panel is on the line.
The 

2100Hz/1300Hz

 option selects the frequency of the ID

tone that is pulsed on the line.

NOTE: Contact your local telephone company to confirm which
settings should be used.

Maximum Dialing Attempts . . . . . . . . . . . . . . . .  Section [160]
Post Dial Wait for Handshake . . . . . . . . . . . . . .  Section [161]
Communicator Call Direction Options  . .  Section [361]-[368]
DTMF or Pulse Dialing  . . . . . . . . . . . . . . . . Section [380]: [3] 
Switch to Pulse Dialing on Fifth Attempt . . . Section [380]: [4]
Communicator Enable/Disable . . . . . . . . . . Section [380]: [1]
Anti-Jam Feature. . . . . . . . . . . . . . . . . . . . . Section [701]: [8]
Pulse Dialing Make/Break Ratio . . . . . . . . . Section [702]: [1]
Force Dialing. . . . . . . . . . . . . . . . . . . . . . . . Section [702]: [2]
ID Tone Enabled . . . . . . . . . . . . . . . . . . . . . Section [702]: [5]
2100Hz/1300Hz  . . . . . . . . . . . . . . . . . . . . . Section [702]: [6]
Bell on FTC/Trouble Only. . . . . . . . . . . . . . . Section [702]: [8]
Delay Between Dialing Attempts  . . . . . . . . . . .  Section [703]

Содержание Power608

Страница 1: ...manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read PC5008...

Страница 2: ...ces or passing traffic Audible warning devices however loud may not be heard by a hearing impaired person Telephone Lines If telephone lines are used to transmit alarms they may be out of service or b...

Страница 3: ...5 Program Descriptions 14 5 1 Programming Security Codes 14 5 2 Zone Programming 14 5 3 Zone Attributes 15 5 4 Assigning Keypad Zones 16 5 5 Communicator Dialing 16 5 6 Communicator Account Numbers 17...

Страница 4: ...ii PC5008 Wiring Diagram...

Страница 5: ...t in piezoelectric buzzer Digital Communicator Specifications Supports major communication formats including SIA and Contact ID Event initiated personal paging Three programmable telephone numbers Two...

Страница 6: ...the PC5928 Audio Interface Module PC5921 EXT Door Box Audio Station Used in conjunction with the PC5928 Audio Interface Module PC5921 EXT R Door Box Audio Station Used in conjunction with the PC5928...

Страница 7: ...out the Programming Worksheets completely before attempt ing to program the system Step 10 Testing the System Test the panel thoroughly to ensure that all features and func tions are operating as pro...

Страница 8: ...These lines may incorporate a voice filter which dis connects the line if anything other than fax signals are detected resulting in incomplete transmissions 2 3 Keybus Operation and Wiring The Keybus...

Страница 9: ...les are supervised upon installation Supervision is enabled at all times so that the panel can indi cate a trouble if a module is removed from the system To check on which modules are currently connec...

Страница 10: ...one input to which a device such as a door contact can be connected This eliminates the need to run wires back to the control panel for every device To install the keypad open the keypad plastic by re...

Страница 11: ...ing Stay arming please see section 3 5 Function Keys on page 10 3 3 Automatic Arming The system can be programmed to Auto Arm at a specific time every day if it is in the disarmed condition In order f...

Страница 12: ...odule being powered by a PC5204 you must also remove and then restore power to the PC5204 and any connected modules This ensures that any troubles present on the module are correctly logged and or ann...

Страница 13: ...ult These settings can be changed Access Code Attributes There are three access code attributes which can be pro grammed for each code To program each attribute enter 5 Master Code 9 to enter the attr...

Страница 14: ...the panel will ignore only one activation of a Delay zone When the Delay zone is secured the panel will end the two minute quick exit delay If a second Delay zone is tripped or if the zone is not res...

Страница 15: ...anual NOTE This function key cannot be programmed for PC55XX LED keypads with software version 1 0 19 7 3 Command Output Option 3 A valid access code may need to be entered 20 For future use 21 7 4 Co...

Страница 16: ...the key to exit the section Select that section again and re enter the information correctly NOTE There must be one digit in each box in the program ming section in order for the change to be valid 4...

Страница 17: ...y pad When a programming section is entered the keypad will immediately display the first digit of information programmed in that section The keypad displays the information using a binary format acco...

Страница 18: ...ry time expires no alarm will be generated 02 Delay 2 Zone The Delay 2 entry delay time can be set independently of Delay 1 in programming section 005 System Times 03 Instant Zone This zone type will...

Страница 19: ...e trouble 23 Maintained Keyswitch Arm Zone When this zone is violated the system will arm When this zone is secured the system will disarm Tampers and faults will not arm disarm the system but only ac...

Страница 20: ...in and search for a dial tone for 5 seconds d the panel will then dial regardless of the presence of dial tone If there is no initial handshake recognized within 40 seconds the panel will then hang up...

Страница 21: ...ed to report events to the central station by sending the Reporting Code programmed for a par ticular event Reporting codes can be one or two digits and can use HEX digits A through F For a complete d...

Страница 22: ...Section 361 to 368 The following is a description of each reporting format Pulse Formats Depending on which pulse format is selected the panel will communicate using the following specifications 3 1 3...

Страница 23: ...e pager once Once the appro priate telephone number is dialed the panel will send the account number and Reporting Code followed by the key Hex C The panel has no way of confirming if the pager was ca...

Страница 24: ...ted Call Up option is enabled the user can have the panel initiate a call to the downloading computer by pressing 6 Master Code 6 The Download Access Code and Panel Identifier Code are for security an...

Страница 25: ...ed to indicate that an alarm has occurred before entering the premises The PGM attributes for this option programmed in Sections 141 to 154 differ from the standard selection of attributes Program whi...

Страница 26: ...outputs PGM attributes return to their default settings when you change PGM output options Please see the programming worksheets for a list of the default settings for each PGM out put type Care shou...

Страница 27: ...me expires Communication of the signal to central station is immediate If the A Key is pressed and held for two seconds the panel will sound the keypad beeps three times to verify activa tion The pane...

Страница 28: ...al applications Bell Squawk on Entry Delay may be enabled The panel will squawk the alarm output once every second until the entry delay expires or the system is dis armed If the Bell Squawk During Au...

Страница 29: ...estoral Reporting Codes Section 338 System Tampers Req Installer Reset Section 701 4 NOTE After enabling keypad tampers it is recommended to tamper and restore all keypads to ensure proper functioning...

Страница 30: ...5 31 Installer s Lockout If Installer s Lockout is selected a hardware default cannot be performed If a software default is performed all program ming will restore to factory default If Installer s L...

Страница 31: ...________________________________________________________________________________________________I Keypad 7 I_____________________________________________I I____________________________________________...

Страница 32: ...Keypads must be installed to use 24 hour Buzzer zones 001 Zone 1 8 Definitions Section 5 2 Zone Programming on page 14 Default Default 01 I_______I_______I Zone 1 04 I_______I_______I Zone 5 03 I____...

Страница 33: ...Status 05 System Armed Status 18 Stay Armed Status 06 Ready To Arm 19 Command Output 1 7 1 07 Keypad Buzzer Follow Mode 20 Command Output 2 7 2 08 Courtesy Pulse 21 Command Output 3 7 3 09 System Tro...

Страница 34: ...Arm Disarm Bell Squawk disabled 5 17 23 OFF I________I 2 Bell Squawk During Auto Arm No Bell Squawk During Auto Arm 5 18 24 OFF I________I 3 Bell Squawk On Exit Delay No Bell Squawk On Exit Delay 5 1...

Страница 35: ...Contact I D Partial Close Identifier is 5 Partial Close Identifier is 4 5 9 18 OFF I________I 5 8 For future use 020 Keypad Zone Assignments Section 2 11 Keypad Zones on page 6 NOTE Only one keypad m...

Страница 36: ...ion 001 Attribute 1 2 3 4 5 6 7 8 ON Audible Steady Chime Bypass Force Swing Tx Delay Wireless Zn OFF Silent Pulsed No No No No No No Zone Type 00 Null Zone N N N N N N N N 01 Delay 1 Y Y Y Y N Y N N...

Страница 37: ...1 11 I________I I________ I________ I________ I________ I________ I________ I________I 152 12 I________I I________ I________ I________ I________ I________ I________ I________I 153 13 I________I I_____...

Страница 38: ...nd Telephone Number 32 Digits Section 5 7 Communicator Telephone Numbers on page 17 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_...

Страница 39: ..._____I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I I_______I_______I 342 Code 25 Code 26 Code 27 Code 28 Code 29 Code 30 Code 31 Code 32 I_______I_______I I_______I...

Страница 40: ..._____I General Zone Trouble Alarm I_______I_______I General Zone Trouble Restore I_______I_______I For future use 352 Test Transmission Reporting Codes Section 5 8 Communicator Reporting Codes on pg 1...

Страница 41: ...5 23 030 I_______I_______I_______I AC Failure Communication Delay 001 255 minutes 5 8 17 003 I_______I_______I_______I TLM Trouble Delay No of checks required valid entries 003 255 5 12 22 030 I______...

Страница 42: ...indow OFF I_______I 3 Call Back Enabled Call Back Disabled OFF I_______I 4 User initiated Call up Enabled User initiated Call up Disabled OFF I_______I 5 8 For future use 402 Downloading Computer s Te...

Страница 43: ...line Test Transmission in minutes Land line Test Transmission in days 5 14 23 OFF I_______I 4 1600 Hz Handshake Standard Handshake 5 9 18 OFF I_______I 5 ID Tone enabled ID Tone disabled 5 5 16 OFF I_...

Страница 44: ...BAD 3 Beeps Squawks 990 Installer Lockout Enable Section 5 31 Installer s Lockout on page 26 991 Installer Lockout Disable Section 5 31 Installer s Lockout on page 26 993 Restore LINKS2X50 Factory De...

Страница 45: ...der Supervisory Alarm Rest panel loses restores supervisory transmission over the Keybus from enrolled PC5132 module or keypads with zone inputs A R 1 43 UA 00 UH 00 328 Cross Zone Police Code Alarm t...

Страница 46: ...T 00 UJ 00 352 Periodic Test periodic system test transmission T 6 A2 RP 00 352 System Test 6 bell communications test T 6 A1 RX 00 352 LINKS Test LINKS test transmission T 6 A3 TX 00 353 Wireless Dev...

Страница 47: ...one 5 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I Default Zone 6 I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I_____I Default...

Страница 48: ...bled ON I_______I 2 A uxiliary Keys enabled A uxiliary Keys disabled ON I_______I 3 P anic Keys enabled P anic Keys disabled OFF I_______I 4 8 For future use 65 Fourth User Display Mask Default Option...

Страница 49: ...Label Broadcast All LCD programming is done per keypad If more than one LCD keypad are present on the system and the PC5400 receives labels labels pro grammed at one keypad can be broadcast to all oth...

Страница 50: ...46 NOTES...

Страница 51: ...6 of the Telecommunications Act 1981 6 It is important that the installer verifies the correct operation of stored telephone numbers subsequent to their entry 7 The connection to this equipment consis...

Страница 52: ...e 18 New PGM Output Type 26 Battery Test See 5 11 PGM Output Options on page 20 New Zone Types 27 Push to Set 28 24 Hr Bell Buzzer See 5 2 Zone Programming on page 14 New Options Troubles are Latching...

Отзывы: