8
To access any option:
1. At the PC5502Z2 keypad, enter [*][8][Installer’s Code]
2. Enter the 2-digit section number of the option you want to change (see options
listed below).
3. To turn the option on or off, press [1].
4. When the option is set correctly, press [#].
5. If you want, you can now enter another programming section; or to exit program-
ming, press [#].
[34] Interior zones force arm
This option is on by default. When this option is turned on, the PC5502Z2 can be armed
when interior zones (zone types 03 and 04) are open. If an interior zone is open, when a
user arms their area, the PC5502Z2 will ignore the zone and arm itself. The zone will
become armed when it is closed (or restored).
[35] Delay zones force arm
This option is off by default. When this option is turned on, the PC5502Z2 can be armed
when delay zones (zone type 01) are open. If a delay zone is open, when a user arms
their area, the PC5502Z2 will ignore the zone and arm itself. The zone will become
armed when it is closed (or restored)
[36] Stay/Away zones interior (option on) or delay (option off)
This option is on (interior) by default. When this option is turned on, zones programmed
as type (04) will work as described in the Stay/Away zone description (page 6). When
this option is turned off (delay), zones programmed as type (04) will operate similarly to
Interior Stay/Away zones, except that they will always provide an entry delay. Typically,
this zone is used for interior protection devices, such as motion detectors. This zone
option helps to prevent false alarms, since it always provides an entry delay time for the
user to turn off the panel.
4.3 Programming Zone Bypass Options
You can program the PC5502Z2 so that users will be able to bypass zones 1 and 2. Users
can use the zone bypassing function when access is needed to part of the protected area
while the system is armed, or if zones are temporarily out of service. Bypassed zones will
not cause an alarm.
By default, the options to allow bypassing of zones 1 and 2 are turned on. To turn off
user bypassing:
1. At the PC5502Z2 keypad, enter [*][8][Installer’s Code]
2. Enter programming section [38] for zone 1, or [39] for zone 2.
3. To turn zone bypassing on or off, press [1].
4. When the option is set correctly, press [#].
5. If you want, you can now enter another programming section; or to exit program-
ming, press [#].