DSC PC 1832 series Alarm Dialler wiring & programming                    RDC_3049_E_TA

 

 

 

DSC PC1832 series  Alarm Panel 

 

Panel Dialler wiring  

 

Panel Dialler programming   

Background:  

 

The PM45 & PM1048-3G (v3) communicator now has a terminal block for the connection of the female 611 fly lead (supplied). 
If the Alarm Panel also has a terminal block for PSTN connection, we recommend you use your own cable between the Alarm 
Panel dialler and PM45 & PM1048-3G (v3).  
This type of installation negates the use of the female 611 fly lead, decreasing your installation time.  
For four (4), six (6) and eight (8) pin RJ connectors, please refer to manufactures wiring diagram. 

 

There are four minimum requirements from the Alarm panel for successful communication: 

1)  Must have an eight (8) digit primary phone. E.g. 12345678 or 55555555. 
2)  A four (4) digit account number. 
3)  Must be Contact ID format. 
4)  Must be set for tone (DTMF) dialling. 
5)  Optional is open / close reporting, must be enabled for Pocket Secure App.  

 
 

 

Dialler Lead wiring between Permaconn and DSC PC 1832 series Alarm Panel: 

DSC PC550

Permaconn

R

R

T

T

1

1

Panel

black

red

green

yellow

red

green

black

yellow

Ring

R1

T1

Tip

 

 

 

 

 

 

 

 

 
 
 

DSC PC 1832 series

 