Section 5: Programming
OFF: When the system is armed, users can not perform a quick exit using [*][0].
4 – Quick Arming /Function Key
ON: [*][0] arming and Stay/Away function keys may be used to arm the system without the entry of a valid access code.
OFF: [*][0] arming is not permitted. All arming functions require the entry of an access code to activate (including Stay/Away
keys).
5 – Not Used
6 – Master Code Not User Changeable
ON: The master code (access code 01) may not be changed by the user and may only be programmed in Installer Pro-
gramming.
OFF: The master code may be programmed by the user using the [*][5][Master Code] command. The master code may also
be programmed in Installer Programming.
7 – Telephone Line Monitor Enable
ON: The TLM function is active and the system indicates a trouble condition when using the [*][2] View Trouble Conditions
command.
OFF: The TLM function is deactivated and telephone line troubles are not indicated by the system.
NA
Note:
Must be ON for UL/ULC listed installations.
8 – Telephone Line Monitor Audible When Armed
ON: When the system is disarmed, a telephone line monitor trouble generates a trouble indication as described above. If the
system is armed, a telephone line monitor trouble generates an audible alarm on the siren for the duration programmed for
bell timeout or until an access code is entered to disarm.
OFF: Telephone line troubles generate a trouble indication, the Trouble LED illuminates, and the keypad buzzer beeps until
a key is pressed.
[016] System Option 4
1 – AC Trouble Display
ON: If AC power fails, the condition is reported to the monitoring station and is indicated as a trouble condition on the system
keypads.
OFF: If AC power fails, the condition is reported, but the Trouble light on the system keypads is off. The trouble is displayed in
[*][2].
NA
Note:
Must be ON for UL/ULC listed installations.
2 – AC Trouble Light Flashes
ON: When AC power is lost, the Trouble light flashes in the base “Ready” and “Armed” mode within 30 seconds of power
loss. When AC restores, the Trouble light stops flashing within 30 seconds. If enabled, this option overrides the AC display
option.
OFF: When AC power is lost, the Trouble light illuminates but does not flash.
3 – Keypad Blanking
ON: If no keys are pressed for 30 seconds, all keypad lights except backlighting (if enabled) are shut off until the next
keypress, entry delay, audible alarm or keypad buzzer condition.
Keypad function keys still operate when the keypad is blank, unless the function key is programmed to require an access
code. Keypad Blanking While Armed overrides this feature. When a partition is armed and in alarm, entering a code to
remove blanking silences the alarm and disarms the system.
OFF: The keypad lights remain ON at all times.
4 – Keypad Blanking Requires Code
ON: A valid access code must be entered before a blanked keypad can be used. Information becomes inaccessible to level
1 users.
OFF: Pressing any key on a blanked keypad removes keypad blanking.
CP-01
Note:
Keypad Blanking Requires Code must be set to off for CP-01 listed installations.
- 88 -