Section 5: Programming
156 – Latched System Event (Strobe)
This output can be used to notify the home owner, before they enter the premises, that an alarm has occurred. This output
can be programmed to activate when any of the following alarms occur on the system:
l
Burglary (Delay, Instant, Interior, Stay/Away and 24-Hour Burglary Zones)
l
Fire (Fire Key, Fire Zones)
l
Panic (Panic Key and Panic Zones)
l
Medical (Medical Key, Medical and Emergency Zones)
l
Supervisory (Supervisory, Freezer and Water Zones)
l
Priority (Gas, Heat, Sprinkler and 24-Hour Latching Zones)
l
Holdup (Holdup zones)
l
Output follows pulse timer (section "[008] PGM Timer Programming" on page 72).
l
Duress
l
Emergency
l
CO Alarm
l
Fire Supervisory
l
Fire trouble
This output does not activate during pre-alert or delays.
In the armed state, the output deactivates only once the system is disarmed.
If an alarm activates this output in the disarmed state, the output deactivates when a user enters a valid access code during
bell timeout. The output also deactivates if someone arms the system after the bell timeout has expired.
If assigned to a single partition, the output activates when an enabled alarm event occurs on the assigned partition. When
assigned to multiple partitions, the output activates when an alarm occurs on any partition and, if configured to latch, will
deactivate when any partition is disarmed. (or a valid disarming procedure is used).
157 – System Tamper
This output activates when any tamper condition is present and deactivates when all tamper conditions are cleared (if set for
steady operation). If set for a pulsed operation, the output deactivates when the PGM Output timer expires. These tampers
include zone tampers (DEOL), case tampers, TLM trouble, RF jam, and all zone and device tampers.
Note:
This PGM does not activate for alternate communicator fault.
161 – DC Trouble
This output activates when one of the following low battery conditions is detected:
l
Alarm controller low or absent battery
l
Module low or absent battery
l
Wireless zone low battery
l
Wireless keypad low battery
l
Wireless siren low battery
l
Wireless key low battery
The output can be configured to follow the state of the low battery trouble(s) or it can activate for a period of time and auto-
matically restore.
165 – Proximity Tag Used
This output activates when the selected proximity tag is presented.
Assign this output to a user by entering a user number from 002 to 095. To enable this attribute for all proximity tags, enter
000 in PGM attribute [011]. See "[007] - [008] PGM Configuration" on page 72.
175 – Bell Status and Programming Access Output
This PGM activates when the siren, Installer Programming mode or DLS/SA is active. It deactivates after bell timeout, when
Installer Programming is exited or when DLS/SA programming is disconnected.
176 – Remote Operation
This output is activated and deactivated remotely on command from DLS software.
Note:
Not for use with UL/ULC listed installations.
- 76 -