Section 5: Programming
With an audible alarm active, using the keyswitch when disarmed is the same as entering an access code at the keypad.
Activating this zone type during the first 30 seconds of a delayed fire alarm is the same as pressing a key at the keypad (the
90 second delay starts). If left in the open state, the system does not arm until the zone is restored and tripped again.
068
–
Momentary Keyswitch Disarm
Use with a keyswitch module. Activating and restoring this zone disarms the partition and silences alarms. Tampers or faults
do not disarm the zone.
Note:
Do not use as a global zone.
069
–
Maintained Keyswitch Disarm
Used with a maintained keyswitch. Activating this zone disarms the partition.
Tampers or faults on this zone do not disarm the partition.
071
–
Doorbell Zone
This zone type sounds a chime through keypads on the partition when activated. No alarms are generated. Various chime
tones can be programmed. Disabling door chime on the partition also disables the chime on this zone.
Note:
Do not use as a global zone.
072
–
Push to Set (Non CP-01 panels only)
Activating this zone starts an infinite exit delay when armed according to the methods described in the table below. To com-
plete the arming sequence, this zone must be activated and restored. Once done, the exit delay timer starts.
Arming Method
Infinite Exit Delay
Arming Mode
User Code
Y
Away
Keyswitch
Y
Away
Away Key
Y
Away
*0 Arm
Y
Away
*9 Arm
N
Stay
Stay Key
N
Stay
Night Key
N
Night
Remote Access/SMS
-
Do Not Use
DLS Arm
N
Away
NAA Arming
N
Away
Do not use exit delay termination with this zone type. Away arming with this zone bypassed prevents arming.
[002] Zone Attributes
Zone attributes are used to customize the operation of zones. When a zone type (section [001]) is programmed, the default
zone attribute is automatically assigned.
When programming attributes using LED/ICON keypads:
l
Ready light ON: Program attributes [1-8]
l
Ready light and Armed light ON: Program attribute [9-16] (press [1] for option 9, press [6] for option 14 etc.)
l
Press [9] to switch between attributes [1-8] and attributes [9-16].
Note:
These attributes override default settings. Do NOT change fire zone attributes from their default settings.
[001]-[128] Select Zone
The attributes listed below can be enabled and disabled for each zone.
01
–
Bell Audible
ON: An alarm activates the siren.
OFF: Silent alarm.
02
–
Bell Steady
ON: Siren output is steady when in alarm.
OFF: Siren output pulses when in alarm.
03
–
Door Chime
ON: The keypad chimes when the zone is open and when the zone is secured.
OFF: The zone does not chime.