Section 4: System Operation
Other programming options that may affect this user function:
See "[990] Installer Lockout Enable/Disable" on page 121
4.7.9 [*][9] No-Entry Arming
This function is used to arm the alarm system while occupants are on the premises. Pressing [*][9] and then keying in an
access code arms the panel without an entry delay on delay type zones and bypasses stay/away and night type zones.
After the exit delay, delay 1 and delay 2 type zones behave the same as instant zones. Stay/away zones remain bypassed.
The entry delay can be activated or deactivated at any time while the system is armed using [*][9].
Note:
If the alarm system is armed using [*][9], disarming is only possible from a keypad inside the premises unless a wire-
less key is used.
Note:
Entry of a valid access code is required following this key only when the system is disarmed. When armed, if pro-
gramming section [015] option 4 (Quick Arming/Function Key) is off, an access code entry is required.
Global delay zones always have an entry delay, even if the system is armed using [*][9].
4.7.10 [*][0] Quick Arm/Exit
This feature operates differently depending on whether or not the alarm system is armed or disarmed.
When disarmed:
Pressing [*][0] arms the alarm system without having to enter an access code. This provides a fast method of arming for reg-
ular users and allows users without an access code to arm the system.
Note:
The Quick Arm feature (section [015] option 4) must be enabled in order for this function to operate as intended. Func-
tion keys also will not require an access code when this option is enabled.
When armed:
This feature provides a means to exit the premises while the alarm system is armed without having to disarm then rearm it.
Pressing [*][0] starts a 2-minute timer that enables any door programmed as a delay zone to be opened and closed once
without triggering an alarm.
If the door is not closed at the end of the 2-minute timer, the entry delay sequence begins. Any additional activity on another
zone triggers the associated alarm or delay sequence.
4.8 SMS Command and Control
The user can perform certain functions on the alarm panel by remote using SMS text messages. In addition, the system
sends SMS messages to the user to confirm commands . SMS programming options are accessed through programming
section [851].
The security system only responds to SMS messages sent from designated phone numbers (programmed in section [851]>
[311]-[342]).
For more information on SMS command and control, and for a complete listing of communicator programming options, refer
to the alternate communicator installation manual.
4.8.1 SMS Command and Control Functions
The following alarm system functions are controllable via SMS:
l
Stay arm the system
l
Away arm the system
l
Night arm the system
l
Disarm the system
l
Activate/deactivate command output 1-4
l
System status request
l
Alarm memory request
l
Zone bypass
l
Zone unbypass
SMS text messages must be formatted as follows:
<function name><space><partition #><space><access code>
- 55 -