Section 4: System Operation
Time and Date
Use this section to program the alarm system clock.
Menu: [*][6][Master Code] > Time and Date
Keypad: [*][6][Master Code] + 01
Enter time and date using the following format: (HH:MM); (MM-DD-YY). Valid time entries are 00-23 hours, 00-59 minutes.
Valid date entries are 01-12 months, 01-31 days.
Other programming options that may affect this user function:
See "System Times" on page 70.
Auto-Arm/Disarm
Menu: [*][6][Master Code] > Auto Arm/Disarm
Keypad: [*][6][Master Code] + 02
With this feature enabled, the alarm system automatically arms in away mode (stay/away zones active) or disarms at a pro-
grammed time each day (see Auto-Arm Time below). The keypad emits three beeps to indicate the system is armed and one
long beep to indicate it is disarmed.
All arming inhibit features such as latching tampers, AC inhibit, etc. also inhibit Auto Arming and send the Auto Arm Can-
cellation code.
Auto-Arm Time
Menu: [*][6][Master Code] > Auto Arm Time
Keypad: [*][6][Master Code] + 03
This function is used to program the time of day each alarm system partition automatically arms. To program an auto-arm
time, select a day of the week and then key in the time. On LED/ICON keypads, zone lights 1-7 represent Sunday to
Saturday. Valid time entries are 00-23 hours: 00-59 minutes.
At the programmed time, the keypad buzzers beep for a programmed duration (for ULC commercial burglary installations
minimum duration is 10 minutes) to warn that automatic arming is in progress. The siren also squawks once every 10
seconds during this warning period if programmed to do so. When the warning period is complete, the exit delay elapses
then the system arms in away mode.
Auto-arming can be canceled or postponed only by entering a valid access code during the programmed warning period.
When a code is entered, the warning is silenced and auto-arming is canceled or postponed, depending on the auto-arm
postpone timer. The Auto Arm Cancellation reporting code is transmitted (if programmed).
Note:
Auto-arming will not silence an active bell.
Note:
The Auto Arm Cancellation reporting code is also transmitted if arming is inhibited by one of the following:
l
AC / DC Inhibit Arm
l
Latching System Tampers
l
Zone Expander Supervisory Fault
Other programming options that may affect this function:
See "[151]-[158] Partition Auto-Arm/Disarm" on page 97
See "[014] System Option 2" on page 86
Enable DLS/Allow System Service
Menu: [*][6][Master Code] > System Serv/DLS
Keypad: [*][6][Master Code] + 05
This function enables and disables the DLS window for either 1 or 6 hours depending on the programming of section [025]
option [7].
This function also enables the end user to provide or deny access to [*][8] Installer Programming. When enabled, the
installer can access Installer Programming either by DLS or via [*8] if a pre-programmed window has been set. After the win-
dow has expired, Installer Programming is unavailable again until the window is re-opened.
Note:
DLS programming is not UL tested.
Other programming options that may affect this function:
See "[020] System Option 8" on page 91, and see "[021] System Option 9" on page 93
See "[025] System Option 13" on page 96, bit "7 – 1 Hour DLS Window"