Section 5: Programming
l
Central Station Account Code: The account code used in programming section [310]. This is a 4 or 6-digit entry.
l
Partition Account Code: Used to identify partition-specific events. All 4 digits must be entered in order to complete the
entry.
l
This account code is entered into programming section [310][001].
l
DLS Access Code: The 6-digit DLS access code used in programming section [403].
l
Partition 1 Entry Delay: The 3-digit entry delay duration for partition 1, in seconds, used in programming [005][001]
option 1.
l
Partition 1 Exit Delay: The 3-digit exit delay duration for partition 1, in seconds, used in programming section [005]
[001] option 3.
l
Installer Code: The 4 or 6-digit installer access code used in programming section [006][001].
For more information on template programming, see "Template Programming Tables" on page 202.
5.3.19 Systems Information
[900] System Information
[000] – Control Panel Version
This read-only section contains the model number, software version, hardware revision, of the alarm controller
.
For example,
an entry of 1234 is read as version 12.34.
[001]-[524] – Module Information
This read-only section is used to view the model number, software version, and hardware revision information of the mod-
ules enrolled on the alarm system.
To view information for a specific module, scroll to the corresponding section:
[001]-[016] keypads
[101]-[115] 8-zone expansion module
[201] 8-output expansion module
[460] Alternate Communicator
[461] HSM2Host module
[501]-[504] 1A power supply module
[521]-[524] high-current output modules 1-4
[901] Installer Walk Test Mode Enable/Disable
This mode tests the operation of each detector in the system. Enter section [901] to initiate a walk test. While in Walk Test
mode, the Ready, Armed, and Trouble LED's on the keypad flash to indicate that the test is active. When a zone is tripped
during the test, a 2-second tone sounds on all system keypads to indicate that the zone is working correctly.
After 10 minutes without zone activity, the alarm system emits 5 beeps every 10 seconds from all keypads. After another 5
minutes of inactivity, Walk Test terminates automatically.
To manually exit walk test mode, enter [901] again.
5.3.20 Module Programming
Use this section to add, remove and confirm the following modules:
l
Keypads see "Compatible Devices" on page 9
l
8-zone expander module (HSM2108)
l
8-output expander module (HSM2208)
l
Power supply (HSM2300)
l
4-output power supply (HSM2204)
l
Wireless transceiver (HSM2HOSTx)
l
Audio Verification Module (HSM2955)
Once added, modules are supervised by the system.
[902] Add/Remove Modules
Modules can be enrolled automatically our manually. In either case, the serial number of the device is used as an identifier.
Select one of the enrollment options described below.
- 117 -