Appendix 2: Reporting Codes

Section #

Definition

Dialer Dir-
ection*

Automatic Contact ID
Codes

SIA Auto Rep Codes**

Miscellaneous Alarms

Duress Alarm - Code entered at keypad

A/R

E(1)21-000

HA-0000/ HH-0000

Opening After Alarm - Disarmed with alarm in memory

A/R

E(4)58-000

OR-0000

Recent Closing - Alarm occurs within two minutes of system
arming

A/R

E(4)59-UUU

CR-UUUU

Burglary Verified

A/R

E(1)39-000

BV-0000

Burglary Not Verified

A/R

E(3)78-000

BG-0000

Alarm Canceled before expiry of alarm cancellation timer

A/R

E(4)A6-UUU

OC-UUUU

Priority Alarm and Restoral Events

[F] Key alarm/restore

A/R

E(1)1A-000
R(1)1A-000

FA-0000 / FH-0000

[A] Key alarm/restore

A/R

E(1)AA-000
R(1)AA-000

MA-0000 / MH-0000

[P] Key alarm/restore

A/R

E(1)2A-000
R(1)2A-000

PA-0000 / PH-0000

Fire alarm by wireless/ alarm restore

A/R

E(1)1A-0000/ R(1)1A-0000

FA-0000/FH-0000

Auxiliary alarm by wireless/ alarm restore

A/R

E(1)AA-0000/ R(1)AA-0000

MA-0000/MH-0000

Panic alarm by wireless/ alarm restore

A/R

E(1)2A-0000/ R(1)2A-0000

PA-0000/PH-0000

Fire alarm by interactive/ alarm restore

A/R

E(1)11A-0000/ R(1)11A-0000

FA-0000/FH-0000

Auxiliary alarm by interactive/ alarm restore

A/R

E(1)AA-0000/ R(1)AA-0000

MA-0000/MH-0000

Panic alarm by interactive/ alarm restore

A/R

E(1)2A-0000/ R(1)2A-0000

PA-0000/PH-0000

Miscellaneous Closing

]

Zone Bypass at time of arming

O/C

E(5)7A-ZZZ

UB-ZZZZ

Zone unbypass

O/C

R(5)7A-ZZZ

UU-ZZZZ

Testing

Walk Test Begin/End

T

E(6)A7-UUU
R(6)A7-UUU

TS-UUUU/TE-UUUU

Periodic Test

T

E(6)A2-000

RP-0000 / RY-0000

Periodic Test with Trouble

T

E(6)A8-000

RY-0000

System Test

T

E(6)A1-000

RX-0000

Maintenance

General System trouble. An RF jam trouble occurred

MA/R

E(3) AA-000

YX-0000

Fire trouble/restore

MA/R

E(3)73-000
R(3)73-000

FT-0000 / FJ-0000

Heat trouble/restore

MA/R

E(3)8A-ZZZ
R(3)8A-ZZZ

KT-ZZZZ / KJ-ZZZZ

Cold Start - System has restarted after total power loss

MA/R

R(3) A5-000

RR-0000

Smoke detector low sensitivity trouble/restore

MA/R

E(3)93-ZZZ

FT-0000/ FJ-0000

Event Buffer 75% Full

MA/R

E(6)22-000

JL-0000

Installer Lead In - Installer Programming has been entered

MA/R

E(6)27-000

LB-0000

Installer Lead out - Installer Programming has been exited

MA/R

E(6)28-000

LS-0000

Panel firmware update begin/ successful

MA/R

E(9)01-900
R(9)01-900

LB-0900 / LS-0900

Panel firmware update fail

MA/R

E(9)02-900

LU-0900

Periodic test with trouble

MA/R

E(6)A2-RRRR

RP-RRRR

*

A/R = alarms/restores; T/R = tampers/restorers; O/C = openings/closings; MA/R = maintenance alarms/restores; T = test transmissions

**

UUU = user number. Note that for CID, enter 999 for user 1000. ZZZ/ZZZZ = zone number.

***

Zones and panic pendants are identified, wireless keys can be identified for openings and closings.

Contact ID & SIA Zone Alarm/Restore Event Codes

(as per SIA DCS: ‘Contact ID’ 01-1999):
The table below defines the meaning of all Contact ID and SIA zone alarm/restore event codes.

- 55 -

Содержание iotega WS910

Страница 1: ... 0 Reference Manual Models WS910 WS912 WARNING This manual contains information on limitations regarding product use and function and information on the lim itations as to liability of the manufacturer The entire manual should be carefully read ...

Страница 2: ...ming Options 25 4 3 1 Other Communicator Related Options 28 4 4 Ethernet Test Transmission 28 4 5 2 Way Voice Options 29 4 6 Partition Configuration Options 30 4 7 Wireless Device Configuration Options 31 4 7 1 Wirefree Keypad Configuration Options 31 4 7 2 Wireless Siren Configuration Options 32 4 7 3 Wireless Key Configuration Options 33 4 7 4 Wireless Smoke and CO Configuration Options 34 4 7 5...

Страница 3: ...rk Troubleshooting 48 Appendix 1 Guidelines for Locating Smoke Detectors and CO Detectors 49 Appendix 2 Reporting Codes 52 Appendix 3 Regulatory Information 58 Appendix 3 EULA 61 Appendix 4 Limited Warranty 62 3 ...

Страница 4: ...Precautions Required During Installation l NEVER install this equipment during a lightning storm l Position cables so that accidents can not occur Connected cables must NOT be subject to excessive mechanical strain IMPORTANT NOTE FOR INTERNATIONAL MARKET EU AUS NZ This equipment is stationary fixed and must be installed by skilled persons only skilled person is defined as a person with relevant ed...

Страница 5: ... Wirefree LCD Keypad WS9LCDWF Cellular Communicator 3G7090E EU PowerG Wireless vanishing door window contact PGx975UL Wireless door window contact w AUX PGx945UL Wireless smoke detector PGx926UL Wireless smoke and heat detector PGx916UL Wireless CO detector PGx913UL PIR Pet Immune Motion Detector PGx914 Wireless PIR motion detector PGx904 P UL Wireless PIR camera motion detector PGx934 P UL Wirele...

Страница 6: ...hone Cellular Phone w Wi Fi iOS Android based Z Wave Devices See the portal for a complete list of supported Z Wave devices Central Monitoring Station Receivers Receiver Sur Gard System I IP Receiver SG System I IP Receiver Sur Gard System II Receiver SG System II Receiver Sur Gard System III Receiver SG System III Receiver Sur Gard System IV Receiver SG System IV Receiver Sur Gard System 5 Receiv...

Страница 7: ...evices supported models PGx901 indoor PGx911 outdoor l Programmable as steady pulsed temporal three as per ISO8201 or temporal four CO alarm l Warning device sounds alarms in the following priority Fire CO Burglary Memory l 128MB RAM l 4GB eMMC solid state drive l 128MB embedded FLASH memory Power Supply Europe Transformer ADP1214 EU Primary 220 240VAC 0 35A 50Hz Class II Secondary 12DC 1 16A Quie...

Страница 8: ...2 EN50131 10 Grade 2 SP2 DP2 requirements System Supervision Features The iotega continuously monitors a number of possible trouble conditions and provides audible and visual indication at the keypad if a trouble is present Trouble conditions include l AC power failure l Zone trouble l Fire trouble l Communicator trouble l Low battery condition l RF jam l Failure to communicate l Module fault supe...

Страница 9: ...e Assign a service plan 1 Select a service plan that corresponds with the panel gateway type you are installing GSM LTE IP or WIFI Note If more than one gateway is installed on the panel select the service plan based on cellular communication GSM or LTE Otherwise select the service plan based on the services provided l Managed Alarm Transport includes alarm signal forwarding only l Interactive Dir...

Страница 10: ... 2 Connect the Ethernet cable to the port on the back of the panel 3 Connect the barrel jack of the plug in adapter to the power connector on the back of the iotega 4 Plug the other end of the Ethernet cable into the wireless router Plug the AC adapter into an electrical outlet The iotega powers up in the following sequence once connected to AC power l The integrated keypad numbers illuminate in s...

Страница 11: ...s wireless keys wire free keypads sirens 2 Navigate to each sub section to customize the device zone names and options as required To wall mount the Panel 1 Select a permanent location near a power outlet The wall should be flat and free from vibration and shock 2 If cables are to be surface run remove the two breakaway tabs from the bottom of the mounting plate Otherwise pass the Ethernet and AC ...

Страница 12: ...p and slide out Push tab to release Figure 2 3 Battery Removal To Install a new battery 1 Insert the battery back end first 2 Press the front of the battery down until the retention tab clicks into place 3 Replace the back cover of the panel 2 2 Controls and Indicators The iotega provides a series of LED indicators to notify users of system status Figure 2 4 LED Indicators 1 2 3 4 5 6 7 8 9 1 Micr...

Страница 13: ... Arm LED s flashing at same time or sys tem test in progress Ready Trouble and Arm LED s flashing at same time OFF Partition is disarmed or audible alarm annunciation is deactivated Trouble ON Steady Amber System trouble is present Single flash Amber 2 System Trouble menu level 1 Two flashes Amber 2 System Trouble menu 2 Three Flashes Amber 2 System Trouble menu 3 Flashing Amber Access code is req...

Страница 14: ...following options to their default settings SSID security key security type and reconnection to DHCP Note The system must be disarmed with no alarms in memory in order for the Reset button to function as described above Tamper Switch The panel includes a tamper switch under the back battery cover If the battery cover is removed while the system is dis armed the tamper condition must be cleared bef...

Страница 15: ...Curtain motion detector PGx904 PIR Pet Immune motion detector PGx926 Smoke detector PGx914 PIR Pet Immune motion detector PGx935 Shock detector and magnetic contact PGx905 Temperature detector PGx944 Tower Cam motion detector PGx911 Outdoor siren PGx945 Magnetic contact with Aux PGx913 Carbon Monoxide detector Note enrolls automatically on power up PGx974 Mirror PIR with anti masking PGx912 Glassb...

Страница 16: ...ion 0 9 numeric entry access code clear entries return to previous screen 2 for Troubles see Viewing Troubles from the Integrated Keypad on page 46 8 to enable WiFi access point to add IP devices i e touchscreen keypad See WPS Mode 8 for more inform ation Shift mode switches between numeric and Emergency keys 3 1 2 Emergency Keys The Fire Auxiliary and Panic keys can be enabled independently by th...

Страница 17: ...ode The WiFi signal strength LED flashes for two minutes to indicate the system is in local webpage mode To access the local webpage 1 On your local device mobile laptop locate the Guest AP network and join 2 Enter your password installer code twice e g 55555555 3 Use a web browser to access http iotega Note The access window timer can be restarted by pressing 8 installer code again 3 2 Arming and...

Страница 18: ...k arming enables users to arm the system via touchscreen or wirefree keypad without entering an access code This provides a fast method of arming for regular users and allows users without an access code to arm the system The Quick Arming feature must be enabled in order for this function to operate See Quick Arm on page 30 3 2 4 Disarming The user must enter through a door programmed as Delay Upo...

Страница 19: ...led Panic Button This function is used to enable or disable the Panic P but ton on the integrated keypad When enabled pressing and holding the P button for 2 seconds sends an emergency alarm reporting code to the central monitoring station Default Enabled Valid range Enabled Disabled Internal Buzzer Control This option is used to set the tone of the internal buzzer The tnoe ranges from lowest 1 to...

Страница 20: ...ormation about the sig nal For example if zone 1 is an entry exit point the event code contains 34 The central monitoring station would receive the following BURG ENTRY EXIT 1 where the 1 indicates which zone went into alarm SIA Format Level 2 Hard Coded The SIA communication format used in this product follows the level 2 specifications of the SIA Digital Communication Standard October 1997 This ...

Страница 21: ...but the alarm is still transmitted if programmed Default Silent Valid range Audible Silent Remote Reset When this option is enabled if an alarm occurs on a burg lary zone the system is locked out after disarming It remains locked until a 5 digit reset code provided by the installer central station is keyed in If a duress code is used to disarm the partition the system is not locked out In the disa...

Страница 22: ...d if the system has gone into alarm during the previous armed period or if a 24 hour alarm has occurred armed or disarmed the system cannot be armed Ready light OFF until Installer Programming is entered or Engineer s Reset is performed via DLS Reset Required is displayed on the keypad This feature also applies to tampers and faults in both armed and disarmed states and does not apply to module ta...

Страница 23: ...orts continuous wireless signals that could interfere with the operation of the alarm system Default Disabled Valid range 00 Disabled 01 UL 20 20 02 EN 30 60 03 Class 6 30 60 Installer Access Window Permission When this option is enabled the installer is given access to the panel s programming sections for a 4 hour window or until the install has been finalized When this option is disabled the ins...

Страница 24: ... If the window expires without an access code entry or a code is entered after the window the communications canceled event is not logged or com municated Note The cancel window does not start after an Emergency key alarm Default 0 Minutes Standard Valid range 0 to 255 Minutes Standard Swinger Shutdown This value defines the number of communication attempts made before the event goes into swinger ...

Страница 25: ...tion operator has 20 seconds to begin another two way voice interval If the new alarm is generated during the last 20 seconds of the two way voice interval the monitoring station operator has the remainder of the interval to begin another two way voice interval Default Disabled Valid range Enabled Disabled 12 24 Hour Clock When this option is enabled time is displayed in 24 hour clock format Defau...

Страница 26: ...anually Bypassed Zones l Stay Zones l Force Arm Zones Default Enabled Valid range Enabled Disabled Periodic Test Transmissions When this option is enabled the following test transmission events are reported to the central monitoring station when they occur When disabled test transmission events are not reported l Periodic Test l Periodic Test with Trouble Default Enabled Valid range Enabled Disabl...

Страница 27: ...ular Login User Name This section is used to program a user name for cellular net work connection Default Blank Valid range 32 ASCII characters or Null Panel s Cellular Login Password This section is used to program a user password for cellular network connection Default Blank Valid range 32 ASCII characters or Null Time Zone This option defines the time zone that the alarm system will operate in ...

Страница 28: ...em troubles Duress code Has access to all features of Basic Standard user including l Arm disarm l Bypass unbypass zones When this code is used for any function a duress code event will be generated User Name label This option is used to program a system user name Default Blank Valid range 32 character ACSII User Enable Locked This option is used to control access to the security system for the se...

Страница 29: ... 1 IP address and port number with identical values Note When operating in common receiver mode Ethernet Receiver 1 account code is used for Ethernet and Cellular Default 127 000 000 001 Valid range 000 000 000 000 to 255 255 255 255 CMS Ethernet 1 Local Port Use this section to set the value of the local outgoing port Set the value of this port when the installation is located behind a firewall a...

Страница 30: ...lar 1 Account Code The account code is used by the central monitoring station to distinguish between transmitters Programming all 0 s or all F s causes a module configuration Trouble A cellular account code is necessary in order for the iotega to communicate to the central monitoring station if cellular communication path is selected Default 0000000000 Valid range 0000000000 to FFFFFFFFFF CMS Cell...

Страница 31: ... 1 Other Communicator Related Options Alternate Test Transmission When this option is enabled the test transmission alternates between primary and secondary receivers with each test transmission interval When disabled the test transmission is sent to the pro grammed receivers based on the settings of the periodic test transmission reporting codes Default Enabled Valid range Enabled Disabled 4 4 Et...

Страница 32: ...le Delay Time This option is used to program the amount of time before the following troubles are transmitted to the central monitoring station l Ethernet trouble l Cellular trouble l Supervision trouble l WIFI trouble Default 000 Valid range 000 to 254 seconds 000 Instant 255 Disabled Visual Verification This feature enables the central monitoring station operator to view images captured via inst...

Страница 33: ... Delay This value determines the time the alarm system delays before transmitting a close delinquency event to the central monitoring station Default 30 Days Valid range 0 to 255 Days Cross Zone Delay If another zone with the Burglary Verification attribute enabled is violated within the duration of this timer a Burg lary Verified event is communicated and logged Default 0 Seconds Valid range 0 to...

Страница 34: ...m occurs during entry delay when EU Entry Procedure is enabled the bell sounds immediately Default 000 Valid range 000 to 255 Minutes Bell Delay Partition Mask This option enables or disables the Bell Delay feature for individual partitions When the option is enabled Bell Delay is applied to the selected partition during alarm conditions When the option is disabled Bell Delay is not applied The de...

Страница 35: ... Armed LED does not illuminate when the sys tem is armed to conserve battery life Default Disabled Valid range Read only Auto Scroll Open Zones Option When this option is enabled the keypad automatically scrolls through and displays all open zones Default Enabled Valid range Read only Alarms Displayed While Armed Option When this option is enabled the keypad displays alarms on affected zones while...

Страница 36: ...lid range Disabled Sounder Only Strobe Only Sounder and Strobe Exit Entry Beeps When this option is enabled the wireless siren beeps whenever entry exit zones are tripped Note When set to Disable in Stay Mode the siren still beeps on entry exit when the system is armed in Away mode Default Disabled Valid range Disabled Enabled Disable in Stay Mode Siren Strobe Alarm This option is used to control ...

Страница 37: ...Valid range 24 hour standard fire Auto verified fire Device Label This section is used to program a custom label for the device Default Zone ZZZ Valid range 32 character ASCII Zone Attribute This section is used to customize zone behavior for the device The table below specifies the status of each attribute for this device See Available Zone Attributes on page 43 for attribute definitions Door Chi...

Страница 38: ...d disable the wireless device Default Enabled Valid range Enabled Disabled Device Partition Assignment This option is used to enable and disable the wireless device Default Enabled Valid range 1 4 Chime Tone This option is used to select the tone emitted by the device when the zone is tripped Default Disabled Valid range Beeps Bing Bing Ding Dong Alarm Tone Zone Type This option is used to program...

Страница 39: ...on Assignment This option is used to assign the wireless device to an avail able partition Default 1 Valid range 1 4 Chime Tone This option is used to select the tone emitted by the device when the zone is tripped Default Disabled Valid range Beeps Bing Bing Ding Dong Alarm Tone Zone Type This programming section is used to program a zone type for the device Default Interior Follower Valid range I...

Страница 40: ...m LED This option is used to enable disable the device s onboard LED When enabled the LED activates when an alarm occurs Default Enabled Valid range Enabled Disabled High Traffic Shutdown Activating this feature helps conserve battery power when the system is disarmed by configuring a reporting timer When motion is detected the device transmits an alarm to the receiver and does not report any furt...

Страница 41: ...ssion Delay Enabled Bell Audible Enabled read only Bell Steady Enabled read only Bypass Enable Enabled read only Force Arm Disabled read only Swinger Shutdown Enabled read only Two Way Audio Enabled read only Talk Listen Enabled read only Supervision This option is used to enable disable wireless supervision of the device Supervision monitors the presence of the wire less device on the alarm syste...

Страница 42: ... Steady Enabled read only Bypass Enable Enabled read only Force Arm Disabled read only Swinger Shutdown Enabled read only Two Way Audio Enabled read only Talk Listen Enabled read only Supervision This option is used to enable disable wireless supervision of the device Supervision monitors the presence of the wire less device on the alarm system Default Enabled Valid range Enabled Disabled Alarm LE...

Страница 43: ...tes when an alarm occurs Default Enabled Valid range Enabled Disabled Reed Switch This option is used to enable disable the device s built in reed switch The reed switch is used in conjunction with the separately mounted magnet as part of the trigger mech anism If the reed switch is enabled and a device is hardwired to the external input terminals both sensors transmit sim ultaniously However the ...

Страница 44: ...Section 4 Programming Options Device Enable Disable This option is used to enable and disable the wireless device Default Enabled Valid range Enabled Disabled 41 ...

Страница 45: ... into full alarm The bell sounds and the event is logged and communicated If another fire zone is activated during the auto verify sequence alarms are imme diately generated for all pending zones This applies to all other fire zone types and to F key alarms If the zone is no longer in alarm at the end of the 40 second delay an 80 second verification timer begins If another fire zone is activated d...

Страница 46: ...e not transmitted but are logged to the event buffer Chime When this attribute is enabled the keypad chimes when the zone is opened or closed Burglary Veri fied When this attribute is enabled zone alarms are not communicated until a burglary verified event occurs Transmission Delay When this attribute is enabled reporting of zone alarms is delayed for the programmed time If a valid access code is ...

Страница 47: ... of the telecommunications service provider 4 11 System Control Use this section to perform the following diagnostic tests System Test This test is used to check that the iotega s siren and LEDs are operating correctly This is a hardware test only No signals are transmitted to the monitoring station During the test the LEDs flash Alarm Control Panel Placement Test This test is used to check the pa...

Страница 48: ...e supervision monitoring period Not Networked The device is registered but not activated on the network NA The device is not registered 4 11 1 Network Cellular Test Transmission Ethernet and Cellular test transmissions check to see if the selected communication path between the iotega and the cent ral monitoring station is functioning correctly Both Ethernet Cellular 1 primary receiver and Etherne...

Страница 49: ...ng numbers on the keypad Refer to the table below for the meaning of each trouble code When in the second level trouble display the trouble LED flashes two times pauses then repeats 7 If additional details are available for the trouble the key illuminates Press any illuminated number to display the third level trouble detail 8 The keypad displays the device number with the trouble condition If mor...

Страница 50: ...ervision 1 9 05 Not Networked 1 9 07 RF Delenquency 1 9 05 Repeater 01 AC 1 8 02 Battery Trouble 1 8 03 Tamper 1 8 04 Fault Supervision 1 8 05 Not Networked 1 8 06 RF Jam 1 8 07 RF Delenquency 1 8 06 Wireless Key 01 Future Use 1 32 02 Battery Trouble 1 32 03 Future Use 1 32 04 Future Use 1 32 05 Not Networked 1 32 07 Communication 01 Receiver Unavailable 02 FTC Trouble receiver 1 4 03 Receiver Sup...

Страница 51: ...e connected to the portal a static IP can be assigned and the iotega taken to the site Network setup details for the installation site are needed to assign a valid IP 7 Static IP on unit No DHCP Eth ernet Wi Fi only The iotega must be provisioned with a router between it and the customer network A router with a static IP for the WAN interface to the network is required The LAN side must have DHCP ...

Страница 52: ...t the presence of joists uninsulated ceilings etc Consult National Fire Alarm Code NFPA 72 CAN ULC S553 02 or other appropriate national standards for installation recommendations l Do not locate smoke detectors at the top of peaked or gabled ceilings the dead air space in these locations may pre vent the unit from detecting smoke l Avoid areas with turbulent air flow such as near doors fans or wi...

Страница 53: ...GENCY INFORMATION Household Fire Safety Audit Read this section for important information about fire safety Most fires occur in the home To minimize this danger we recommend that a household fire safety audit be conducted and a fire escape plan be developed 1 Are all electrical appliances and outlets in a safe condition Check for frayed cords overloaded lighting circuits etc If you are uncertain a...

Страница 54: ...point where everyone can be accounted for e g across the street or at a neighbour s house Once everyone is out of the building call the fire department l A good plan emphasizes quick escape Do not investigate or attempt to fight the fire and do not gather belongings as this can waste valuable time Once outside do not re enter the house Wait for the fire department l Write the fire escape plan down...

Страница 55: ... 3 83 603 R 3 83 603 TA 0603 TR 0603 Keypad 4 tamper restore alarm T R E 3 83 604 R 3 83 604 TA 0604 TR 0604 Siren 1 tamper restore alarm T R E 3 83 801 R 3 83 801 TA 0801 TR 0801 Siren 2 tamper restore alarm T R E 3 83 802 R 3 83 802 TA 0802 TR 0802 Siren 3 tamper restore alarm T R E 3 83 803 R 3 83 803 TA 0803 TR 0803 Siren 4 tamper restore alarm T R E 3 83 804 R 3 83 804 TA 0804 TR 0804 Siren 5...

Страница 56: ...ttery over voltage charge restore MA R E 3 14 000 R 3 14 000 YP 000 YQ 000 Alternate Communicator Alternate Communicator radio SIM trouble restore MA R E 3 AA 001 R 3 AA 001 YX 0001 YZ 0001 Alternate CommunicatorGSM Network trouble restore MA R E 3 AA 001 R 3 AA 001 YX 0001 YZ 0001 Alternate Communicator Ethernet trouble restore MA R E 3 AA 001 R 3 AA 001 YX 0001 YZ 0001 Alternate Communicator Rec...

Страница 57: ...R E 3 A1 905 R 3 A1 905 AT 0905 AR 0905 Repeater 6 AC fail restore MA R E 3 A1 906 R 3 A1 906 AT 0906 AR 0906 Repeater 7 AC fail restore MA R E 3 A1 907 R 3 A1 907 AT 0907 AR 0907 Repeater 8 AC fail restore MA R E 3 A1 908 R 3 A1 908 AT 0908 AR 0908 RF jam trouble restore E 3 44 0000 XQ 0000 XH 0000 Wireless repeater 1 8 RF jam trouble restore E 3 44 901 908 R 3 44 901 908 XQ 901 908 XH 901 908 Wi...

Страница 58: ... of arming O C E 5 7A ZZZ UB ZZZZ Zone unbypass O C R 5 7A ZZZ UU ZZZZ Testing Walk Test Begin End T E 6 A7 UUU R 6 A7 UUU TS UUUU TE UUUU Periodic Test T E 6 A2 000 RP 0000 RY 0000 Periodic Test with Trouble T E 6 A8 000 RY 0000 System Test T E 6 A1 000 RX 0000 Maintenance General System trouble An RF jam trouble occurred MA R E 3 AA 000 YX 0000 Fire trouble restore MA R E 3 73 000 R 3 73 000 FT ...

Страница 59: ...Z R 1 1A ZZZ 24 Hr Low Temperature ZA ZZZZ ZH ZZZZ E 1 59 ZZZ R 1 59 ZZZ 24 Hr High Temperature KA ZZZZ KH ZZZZ E 1 58 ZZZ R 1 58 ZZZ 24 Hr Non Alarm Walk Test Only BA ZZZZ BH ZZZZ E 1 3A ZZZ R 1 3A ZZZ 24 Hr Supervisory Buzzer UA ZZZZ UH ZZZZ E 1 5A ZZZ R 1 5A ZZZ 24 Hr Auto Verified Fire Wireless FA ZZZZ FH ZZZZ E 1 1A ZZZ R 1 1A ZZZ 24 Hr CO Alarm GA ZZZZ GH ZZZZ E 1 62 ZZZ R 1 62 ZZZ 24 Hr Hol...

Страница 60: ...Appendix 2 Reporting Codes 57 ...

Страница 61: ...e not included in the evaluation of this product under the requirements of the above mentioned standards The certified wirefree keypad HS2LCDWF8 P N WS9LCDWF8 shall be used in order to ini tiate the walk test mode for model WS912 28 Additional features implemented for EN 50131 Grade 2 Fire alarm and CO alarm annunciation Auxiliary medical alarm annunciation This device is suitable for use in syste...

Страница 62: ...re Default Enabled Required Auto Stay Arm on Un vacated Premises Zones must be programmed as stay Away Function Key Stay Arming All Stay Away type zones will be automatically bypassed If no exit after full arm Default Enabled Required Entry delay s Panel Settings Panel Con figuration Partition Configuration Entry Delay select 30s 45s 60s 2mins 3mins or 4mins Access to Entry and Exit delays and Bel...

Страница 63: ...o the swinger shutdown limit for zone alarms For all non fire zones shut down at 1 or 6 trips Default 2 trips Required programmable 24 hour auto verified Fire Access to 24 hour auto verified Fire Activates If a restore is Not received within the spe cified time Default dis abled Required System Test Panel Settings Dia gnostics Sys tem System Test The system activates all keypad sounders bells or s...

Страница 64: ...rovided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT Termination Without prejudice to any other rights DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA In such event You must destroy all copies of the SOFTWARE PRODUCT and all of its component...

Страница 65: ... of merchantability or fitness for a particular purpose And of all other obligations or liabilities on the part of Digital Security Controls Digital Security Controls neither assumes responsibility for nor authorizes any other person pur porting to act on its behalf to modify or to change this warranty nor to assume for it any other war ranty or liability concerning this product This disclaimer of...

Страница 66: ...such as when the fire is in a chimney walls or roofs or on the other side of closed doors Smoke detectors may not detect smoke from fires on another level of the residence or building Every fire is different in the amount of smoke produced and the rate of burning Smoke detectors cannot sense all types of fires equally well Smoke detectors may not provide timely warning of fires caused by carelessn...

Страница 67: ...formation will be retained as long as necessary to achieve the purpose for which it was collected and for any period thereafter as legally required or permitted by applicable law The trademarks logos and service marks displayed on this document are registered in the United States or other countries Any misuse of the trademarks is strictly prohibited and Tyco will aggressively enforce its intellect...

Отзывы: