Section 4: Programming Options
4.7.10 Wireless Door Window Con-
figurations
The following sections are used to program wireless
door/window contacts.
Device Label
This option is used to program a custom label for the wire-
less device.
Default:
Zone ZZZ
Valid range:
32 character ASCII
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
Enabled/Disabled
Zone Type
This option is used to program a zone type for the device.
Default: 24-hour Temperature
Valid
range:
Delay 1, Delay 2, Instant (Perimeter), Interior Follower, Interior
Stay/Away, Delay Stay/Away, Day Zone, 24Hour Burglary, 24Hour
Silent Holdup, 24Hour Audible Panic, 24Hour Medical Alarm, 24Hour
Supervisory Buzzer, 24Hour Non-Alarm
Device Partition Assignment
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
1-4
Chime Tone
This option is used to select the tone emitted by the device
when the zone is tripped.
Default:
Beeps
Valid range:
Beeps, Bing Bing, Ding Dong, Alarm Tone
Zone Attribute
This section is used to customize zone behavior for the
device. The table below specifies the status of each attribute
for this device.
See "Available Zone Attributes" on page 43 for attribute
definitions.
Door Chime
Disabled
Alarm Report
Enabled
Burglary Verified
Enabled
Transmission Delay
Enabled
Bell Audible
Enabled (read-only)
Bell Steady
Enabled (read-only)
Bypass Enable
Enabled (read-only)
Force Arm
Disabled (read-only)
Swinger Shutdown
Enabled (read-only)
Two Way Audio
Enabled (read-only)
Talk Listen
Enabled (read-only)
Supervision
This option is used to enable/disable wireless supervision of
the device. Supervision monitors the presence of the wire-
less device on the alarm system.
Default:
Enabled
Valid range:
Enabled/Disabled
Alarm LED
This option is used to enable/disable the device’s onboard
LED. When enabled, the LED activates when an alarm
occurs.
Default:
Enabled
Valid range:
Enabled/Disabled
Reed Switch
This option is used to enable/disable the device’s built-in
reed switch. The reed switch is used in conjunction with the
separately mounted magnet as part of the trigger mech-
anism.
If the reed switch is enabled and a device is hardwired to the
external input terminals, both sensors transmit sim-
ultaniously. However, the iotega treats both devices as the
same zone. Disable the reed switch to have the hardwired
device funciton independently.
Default:
Enabled
Valid range:
Enabled/Disabled
Zone EOL Configuration
This option is used to configure end of line resistors for the
external input terminals. The alarm panel uses EOL resistors
to monitor for fault or alarm conditions.
Default:
EOL Disable
Valid range:
Single, EOL Disable, Normal Open, Normal Close
4.7.11 Wireless Shock Sensor Con-
figurations
The following sections are used to program wireless shock
sensors.
Device Enable/Disable
This option is used to enable and disable the wireless
device.
Default:
Enabled
Valid range:
Enabled/Disabled
- 39 -