background image

AMB-500

Addressable PIR Detector

INSTALLATION INSTRUCTIONS

The AMB-500 is a ceiling mount detector designed to provide reliable motion detec-
tion for residential and commercial applications. The AMB-500 uses a special Fresnel
lens made for 360° detection in conjunction with a quad element PIR sensor opti-
mized for uniform detection all around its field of view. Special attention is given to
false alarm immunity against RF, static, electrical transient to ensure trouble free oper-
ation for many years.

The AMB-500 uses a 2-wire connection for power and to communicate with the con-
trol panel. This simplifies wiring and reduces installation cost. The AMB-500’s low cur-
rent draw also maximizes the number of devices that can be attached to an
addressable loop.

Specifications

• Current rating: 0.75 mA (standby); 3 mA (test mode)

• Operating environment: 32°F-120°F / 0°C-49°C; 5%-93% RH, non-condensing

• Radiated RF immunity: 10 V/m with 80% AM over range, 80MHz to 1.0GHz**

• Conducted RF immunity: 10V with 80% AM over range 150kHz to 100MHz**

• Static immunity: 15 kV

• Transient immunity: 2.4 kV @ 1.2 joules

• Maximum detection range (diameter)

Detector placed 8 ft./ 2.4 m from floor: 24 ft./ 7.3 m
Detector placed 10 ft./ 3.0 m from floor: 30 ft./ 9.2 m
Detector placed 12 ft./ 3.6 m from floor: 40 ft./ 12.2 m

• Walk detection speed: 0.5-10'/s (0.15-3m/s)

• Tamper switch contact rating: 0.1A @ 24V

DC

Control Panel Compatibllity

• PC4010/4020 v3.x

• PC5010/PC5015/PC5020 v2.x with 

PC5100 interface module

∗ 

∗ 

∗ 

∗ 

Protected by one or more of the following patents: 
Canada 2099971, US 5444432

** RF immunity and white light not verified by UL

firealarmresources.com

Содержание AMB-500

Страница 1: ...he number of devices that can be attached to an addressable loop Specifications Current rating 0 75 mA standby 3 mA test mode Operating environment 32 F 120 F 0 C 49 C 5 93 RH non condensing Radiated RF immunity 10 V m with 80 AM over range 80MHz to 1 0GHz Conducted RF immunity 10V with 80 AM over range 150kHz to 100MHz Static immunity 15 kV Transient immunity 2 4 kV 1 2 joules Maximum detection r...

Страница 2: ... sunlight directly onto the detector Avoid locations that are subject to direct high air flow such as near an air duct out let Do not locate the detector near sources of moisture steam or oil Do not aim the detector such that it will receive direct or reflected mirror sunlight Do not limit the coverage by large obstructions within the detection area such as plants or filing cabinets Device Wiring ...

Страница 3: ...ct only DSC Addressable Series devices to the addressable loop connections Connection of ANY other type of device will impair operation Any devices other than Addressable Series devices which require power to oper ate must be powered separately Walk Testing Once the detector has been set up walk test the entire area where coverage is desired Should the coverage be incomplete readjust or relocate t...

Страница 4: ...regoing warranty shall apply only to the original buyer and is and shall be in lieu of any and all other warran ties whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd Digital Security Controls Ltd neither assumes nor authorizes any other person purporting to act on its behalf to modify or to change this warranty nor to assume for ...

Отзывы: