The programmed number in Communicator must also be programmed as the panel phone number. When the communicator
detects the phone number it will communicate to the receivers to the corresponding group.

NOTE:

If no PTM phone number is programmed, all panel calls will go to Receiver Group 1.

Troubleshooting Guide

Powering up the 3G4010CF

– when powering up the 3G4010CF, always connect the battery first (if used) before connecting

primary DC power from the control panel or transformer.

Wiring Primary

– R-1/T-1 of 3G4010CF to RING/TIP of control panel, DC power from control panel or DC transformer to DC

input, backup battery.

Wiring Backup

– Incoming line to RING/TIP on 3G4010, R-1/T-1 of 3G4010CF to RING/TIP of control panel, R-1/T-1 of control

panel to house phones, DC power from control panel or DC transformer to DC input, backup battery.

Testing Communications

– when the 3G4010CF transmits a signal for the control panel, or for an internal transmission, the

BLUE light will flash one time when the signal is transmitted and two times when it gets a kiss-off.

SIM

– the SIM should be activated at least 24 hours prior to installation. The 3G4010CF will show signal strength with an inact-

ive SIM, however it will display the signal strength of any available wireless network. The SIM must be active to ensure the sig-
nal strength displayed is that of the wireless network provider for which the SIM belongs to.

Panel Programming

– the control panel should be programmed to communicate Contact ID or SIA exactly the same way it

would be programmed to communicate Contact ID or SIA over the telephone line.

Green/Yellow

LED Status

What it

means:

CSQ Values

Signal Strength Status

Both Signal Strength
LEDs

ON

Excellent

Signal

Strength

14+

l

Unit can be installed in the current mounting location.

Top LED

FLASHING

with

bottom LED

ON

Excellent

Signal

Strength

11-13

l

Unit can be installed in the current mounting location.

Bottom LED

ON

Good Signal

Strength

7-10

l

Unit can be installed in the current mounting location.

Bottom LED

FLASHING

Poor Signal

Strength

5-6

(no trouble)

1-4

(with trouble)

l

Ensure the antenna cable is plugged securely into the radio
connector.

l

If the SIM is active, connect a battery to the unit and test
various locations for good/excellent signal strength.

l

Connect an antenna extension kit (GS-15ANT, GS-25ANT,
GS-50ANT or GS8-ANTP).

Both LEDs

OFF

No Signal

Strength

0

l

If the red LED is also FLASHING, refer to the RED LED chart.

l

Verify SIM card is activated.

l

Ensure the antenna cable is plugged securely into the radio
connector.

l

If the SIM is active, connect a battery to the unit and test
various locations for good/excellent signal strength.

l

Connect an antenna extension kit (GS- 15ANT, GS-25ANT,
GS-50ANT or GS8-ANTP).

Both LEDs

Flashing

ON/OFF

together

Signal

Strength is

invalid

N/A

Radio is in process of network registration.

Both LEDs

Alternating

Radio Reset

Sequence

N/A

Radio is performing a Reset. If the issue persists, please verify the
SIM card is inserted correctly.

NOTE:

When the Signal Strength LED is showing Green, it indicates your communicator is connected to a 3G Tower. When

the Signal Strength LED is showing Yellow, it indicates your communicator is connected to a 2G Tower.

Blue LED Status

(Normal Mode)

What It Means: Wireless Communicator Status/Communication Indicator

Blue LED

ON

When used as a backup communicator, the blue LED will be ON when there is a no phone line
connected to the 3G4010CF TIP and RING, or the line voltage goes below 2.8VDC.

Blue LED

OFF

A good phone line is connected to the 3G4010CF . (more than 2.8 VDC detected across the 3G4010CF
TIP and RING terminals).

15

Содержание 3G4010CF

Страница 1: ...ercial RF Communicator 3G HSPA Network Signaling Devices INSTALLATION MANUAL V4 0 Warning This manual contains informationon limitations regarding product use andfunction and inform ationonthelimitati...

Страница 2: ...Principles 10 Simulated Landline Mode 10 Panel Transmission Monitoring PTM 10 Cellular Communications Sequence 11 Inputs 11 Outputs 11 Activating the Outputs 11 Reporting Codes 12 Swinger Shutdown 12...

Страница 3: ...uper vision window for reporting single technology communicator trouble shall be set to five minutes However the product can be installed in accordance with the requirements ofNFPA72 2013 edition whic...

Страница 4: ...ng voltage 13 75Vdc Battery charge current 700mA maximum NOTE Battery mustbe replaced every 3 5 years Operating frequency 2G GSM GPRS EDGE 850 1900MHz Operating frequency 3G UMTS HSPA 850 1900MHz Ante...

Страница 5: ...3G Antenna 2 Metal Casing 3 Antenna Mounting Hardware 4 Antenna Connector 5 Anchor Screw Holes 3mm 6 SIM Card Holder 7 3G HSPA Radio Module 8 Status LEDs See page 1 Part 9 PC Link Connector 10 Tamper...

Страница 6: ...eatsent The 3G4010CF is designed to work with the ContactID com munication formatas described in SIADC 05 Standard or the 300 baud SIA communication formatas described in SIA DC 03 standard Every 24 h...

Страница 7: ...ll move to Step 3 and scan for carriers with sufficientsignal strength and attach to the carrier Ifthe 3G4010CF is connected to a carrier with sufficientsignal strength min imum ofbottom signal streng...

Страница 8: ...reen Top Yellow Green Bottom ON ON ON FLASHING and turn on solid when itreceives a communication back from the central station Red Blue Yellow Green Top Yellow Green Bottom ON ON ON ON Ifat leastone o...

Страница 9: ...iate an AC trouble by flashing the RED status LED 9 times and will delay the AC loss eventtransmission by one hour LBT Battery Trouble This open collector outputactivates when a Battery Trouble condit...

Страница 10: ...ndline has been restored the 3G4010CF switches the connected device back to the landline OR l Ifthe landline is still down the 3G4010CF continues the simulation until the landline is restored The 3G40...

Страница 11: ...ContactID or SIA formatwith Inputs 1 4 reporting as 991 to 994 respectively Defaultsettings are INPUT 1 AC LOSS INPUT 3 FIRE ALARM INPUT 2 FIRE SUPERVISORY INPUT 4 SYSTEM TROUBLE Inputs can be config...

Страница 12: ...oes notsupportremote programming local hardware defaultrequired Upon activation through Con nect24 the productwill operate as described in this manual Swinger Shutdown To prevent runaway signals to th...

Страница 13: ...on offtogether indicates the radio is notready This LED sequence will display until the low battery voltage is restored and the radio is enabled again SMS Command and Control NOTE For UL ULC installa...

Страница 14: ...uage Command Label shallnot be case sensitive English Disarm French Desarmement Spanish Desarmado l Activate PGM Language Command Label shallnot be case sensitive English Activate French Activation Sp...

Страница 15: ...gnal Strength 14 l Unitcan be installed in the currentmounting location Top LED FLASHING with bottom LED ON Excellent Signal Strength 11 13 l Unitcan be installed in the currentmounting location Botto...

Страница 16: ...e antenna cable is plugged securely into the radio connector l Ifthe SIM is active connecta battery to the unitand testvarious locations for good excellentsignal strength l Connectan antenna extension...

Страница 17: ...connector Gently turn the screwdriver away to pop outthe connector from the modem l To install the antenna firmly push the connector into the modem until it snaps into place Enrolling a 3G4010CF l Th...

Страница 18: ...0CF with PC5700 Interface Use No 26 AWG wires for the connection to PSTN Phone line connection is required only for back up configurations In stand alone applications no other communication technology...

Страница 19: ...gered when the 3G4010CF is locally or remotely restar ted Please contactpanel vendor for details on how to resetthe control panel PGM Figure 4 Power Supply Wiring Diagram PS4085 12V COM ACT LBT TEST B...

Страница 20: ...6 19 Z4 Z3 Z2 COM 20 Z1 AUX PGM 3 PGM 1 PGM 4 COM 3G4010CF PGM 3 DC IN DSC Supervision Relay See Note Power Supply Provides power to the 3G4010CF Module NOTES 1 Program the zone pointas Supervisory ty...

Страница 21: ...nycopiesof the SOFTWARE PRODUCT are owned by DSC or its suppliers You may not copythe printed materialsaccompanying the SOFTWAREPRODUCT Alltitle and intellectualpropertyrightsin and to the contentwhic...

Страница 22: ...ission public service commission orcorporation commission for information Alarm dialling equipment must be able to seize the telephone line and place a call in an emergency situation Itmustbe able to...

Страница 23: ...acilitiesorservices down time pur chaser stime the claimsof third parties including customers and injury to prop erty The laws of some jurisdictions limit or do not allow the disclaimer of consequenti...

Страница 24: ...o willaggressively enforce its intellectualproperty rightsto the fullestextent ofthe law including pursuitofcriminal prosecution wherever necessary All trademarksnotowned byTyco are the propertyofthei...

Отзывы: