
28
with the same values. When operating in common receiver mode the Ethernet
Receiver 2 account code will be used for communications over Ethernet and Cellular.
NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 to communicate
to same receiver.
[114] Ethernet Receiver 2 Remote Port
Default (0BF5/3061)
This Section is used to program the port number used by Ethernet Receiver 2. Set
the value of this port when your installation is located behind a firewall, and must be
assigned a particular port number as determined by your central station system
administrator. Valid range: 0000 - FFFF.
NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 Port with the
same value.
[115] Ethernet Receiver 2 Local Port
Default (0BF9/3065)
Use this Section to program the value of the local outgoing port. You can set the
value of this port when your installation is located behind a firewall and must be
assigned a particular port number as determined by your network administrator. Valid
range: 0000 - FFFF.
NOTE: Do not program Ethernet Receiver 1 and Ethernet Receiver 2 Port with the
same value.
[116] Ethernet Receiver 2 Domain Name
Default ( )
i
Programming this Section is
not
permitted on a UL/ULC listed system.
Enter the Domain Name as 32 Character ASCII.
E
THERNET
O
PTIONS
[124] Ethernet Test Transmission Time
Default (9999)
Enter a 4 digit number (0000-2359) using the 24-hour clock format (HHMM) to set the
test transmission time of day.
Valid range: 00 - 23 hours (HH) and 00 - 59 minutes (MM). Programming a value of
9999 will disable the test transmission time.
NOTE: The internal date and time will automatically be programmed when the unit
communicates with the primary receiver.
[125] Ethernet Test Transmission Cycle
Default (000000)
This value represents the interval between test transmissions, in minutes. Valid
range: 000000 - 999999 minutes. Once the unit has sent the initial periodic test
transmission, all future test transmissions will be offset by the programmed number
of minutes. See Sections [026] - [029].
NOTE: Minimum value is 000005 minutes. Programming an interval that is less than
5 minutes will disable test transmission.
C
ELLULAR
R
ECEIVER
1 O
PTIONS
[201] Cellular Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters.
This account code is used when transmitting heartbeat signals to the central station
receiver. Signals received from the control panel will use the control panel account
Table 12: Ethernet Test Transmission Interval
Test Transmission Interval
Daily
Weekly
Monthly
Programmed Minutes
001440
010080
043200