Dry-Matic DM01D Скачать руководство пользователя страница 1

DM - Operating Instructions, Installation Instructions, Wiring diagrams  

 

     Version 3.1.765 August 2019

1

Dry-Matic

with Digital Controller

 

• 

User Operating Instructions  p2-5

• 

Installation  Instructions 

 p6-9

• 

Setup  Instructions 

 p10-15

• 

Error  Codes 

 p13

• 

Wiring Diagram  

 p14

• 

Warranty   

 p16

Digital controller

Содержание DM01D

Страница 1: ...ructions Wiring diagrams Version 3 1 765 August 2019 1 Dry Matic with Digital Controller User Operating Instructions p2 5 Installation Instructions p6 9 Setup Instructions p10 15 Error Codes p13 Wiring Diagram p14 Warranty p16 Digital controller ...

Страница 2: ...very takes advantage of solar gain to the roof space on those sunny winters days Dry Matic digital controller shown in normal operating mode Standard Unit DM01 Ceiling Diffuser Dry Matic Heated Unit Mode H F Heat Rec C C 11 16 18 30 Operating Mode Attic Temperature TA House Temperature TH Time Adjustment buttons H displays when heater operating Bars indicate of heat capacity F Fan Bars indicate fa...

Страница 3: ...ptimal performance clean at least yearly If the filter timer is activated the hall controller display will start flashing Dirty Filter to indicate it is time to clean the filters The white filter bag can be machine washed on gentle cycle or hand washed vacuum first to remove excess dust Alternatively replace with a new one The carbon filter inside the filter box should be replaced every year You m...

Страница 4: ... get to User Menu press and hold mode button continue holding while Entering Menus appears hold until User Setup shows Use the up arrow to change the options Mode button to select Heater enabled Y N if N Heater will not operate Heater enabled Y N if Y Options will show next Heater Continuous if Y Heater always enabled Heater Continuous if N Heater enabled at night Reset Timer Y N if Y Timer displa...

Страница 5: ...ards Press the Mode button to enter the new setting Reference Temperature default 20 C is set in the commissioning menu Default Setting can be adjusted in the commissioning menu Please note the above modes need to be set by the installing contractor Dry Matic User Operating Instructions continued TA Attic temperature shown in operating display TR Inside reference temperature TH House temperature s...

Страница 6: ...ir condition temperature of the unit The attic controller must be installed vertically with the pack glands downwards The attic controller can be fixed to the timber framing in the roof space Hall Controller Hall controller is to be installed in the house at least 3m from the diffuser but in the same area approx 1 5m above the floor The hall controller should not be installed on an external wall i...

Страница 7: ... fan and heater on heated models Check wiring diagrams on components carefully 4 Installing in Attic Lift assembled unit into attic space Fit supplied cup hooks x2 to roof structure Clip supplied bungies x3 to the three mounting points on assembled unit Lift unit into position and hook other end of bungy cords over cup hooks Attach duct to fan outlet taping core and insulation outer as before Adju...

Страница 8: ...DM Operating Instructions Installation Instructions Wiring diagrams Version 3 1 765 August 2019 8 Smooth Air Products Ltd Dry Matic Insta ...

Страница 9: ...DM Operating Instructions Installation Instructions Wiring diagrams Version 3 1 765 August 2019 9 allation Schematic ...

Страница 10: ...ing and holding the up and down buttons for 3 5 seconds until Setup Menu is displayed Menu can be scrolled through by pressing the mode button If no button is pressed for 15 seconds unit will revert to operating mode therefore it is recommended that any changes are planned in advance Use form on p13 to pre plan settings Hold mode buton to cycle through options quickly Available modes are also desc...

Страница 11: ...eat default 32 range 30 45 option only for heated models This must be set to ensure that minimum speed is sufficient to ensure heater sail switch operates with semi dirty filter and provides sufficient airflow to the number of outlets installed balanced against too much airflow that will limit temperature rise through the heater Adjustment range 30 45 At default setting nominal temp rise is 9 C fo...

Страница 12: ...eg use 2 if controller reading 2 C too high 14 Heat P band default 3 range 1 7 C option only for heated models At a proportional band of 3 C heater will start to operate at attic temp 15 C and is fully on when temperature gets down to 12 C A smaller proportional band will bring heater on over a smaller temperature range 15 Heat Reco P band default 3 Heat Recovery Proportional Band With proportiona...

Страница 13: ...ree Offset C 0 13 I Side Degree Offset C 0 14 Heat P band C 3 15 Heat Reco P band C 3 16 Cool Reco P band C 3 17 Summer Temp S down C Yes 27 18 User On Off Y N N 19 Factory Reset Y N N Error Codes Swap Fltr Filter due for change Timer Err Filter timer is misbehaving reset timer see p4 c2 Heater Fault No heater current flowing check circuit Heater Err Fan speed is too low in the software Fan sanity...

Страница 14: ... details supplied with heater Cable for electrical supply is three core and pre wired to the attic controller Dry Matic Wiring Diagram Attic Controller for DM15D only Heater for DM07D DM15D Mode H F Heat Rec C C 11 16 18 30 Supplied cable for the fan unit is two core wire to N P1 N P Fan unit Optional Summer Vent kit 1 2 3 P N P1 N P3 N NC C 240VAC MOTOR HEAT Vent Circuit Board Patch lead socket I...

Страница 15: ...ll controller For digital controller mount vertically with pack glands downwards Attic Controller The attic controller must be mounted vertically with pack glands downwards Easy plug in connection between attic and hall controllers and comes through here Mount vertically with pack glands downwards to fan to heater for DM07 DM15 Electrical supply Isolator switch ...

Страница 16: ...hole or cavity in the ceiling that was installed as part of the installation of the goods will be left in place The money back guarantee does not cover separate installation costs or the repair of the hole used by the unit The cost for the repair of ceiling holes or other ventilation holes if required is either deductible from the refund or an additional cost payable by the Purchaser WARRANTY RETU...

Отзывы: