background image

12.

 

DIMENSIONS 

 

 

Version WITH RESERVOIR for GREASE 

Part number 

Command 

3414008 

Single acting 

576 - 

[22.6]

 

876 - 

[34.4]

 

130 - 

[5.11]

 

276 - 

[10.86]

 

75 - 

[2.95]

 

3414012 

511 - 

[20.1]

 

761 - 

[29.9]

 

195 - 

[7.6]

 

276 - 

[10.86]

 

75 - 

[2.95]

 

3414050 

523 - 

[20.6]

 

736 - 

[28.97]

 

196 - 

[7.7]

 

280 - 

[11.02]

 

75 - 

[2.95]

 

3414022 

511 - 

[20.1]

 

661 - 

[26.02]

 

192 - 

[3.5]

 

276 - 

[10.86]

 

75 - 

[2.95]

 

3414014 

Dual acting 

511 - 

[20.1]

 

761 - 

[29.9]

 

192 - 

[3.5]

 

276 - 

[10.86]

 

75 - 

[2.95]

 

Version WITHOUT RESERVOIR for OIL 

Part number 

Command 

3414004 

Single acting 

120 - 

[4.7] 

276 - 

[10.86]

 

80 - 

[3.1] 

3414009 

115 - 

[4.5] 

276 - 

[10.86]

 

65 - 

[2.5]

 

3414007 

Dual acting 

115 - 

[4.5] 

276 - 

[10.86]

 

83 - 

[3.2]

 

3414017 

120 - 

[4.7] 

330 - 

[12.3] 

72 - 

[2.8]

 

Dimensions in 

mm [in] 

Содержание 3414 Series

Страница 1: ...nches and authorised distributors Go to www dropsa com or write to sales dropsa com C2014IE WK 14 19 1 INTRODUCTION 2 GENERAL DESCRIPTION 3 PRODUCT IDENTIFICATION 4 TECHNICAL CHARACTERISTI 5 COMPONENT...

Страница 2: ...out reservoir for applications on special reservoirs or reservoirs owned by the customer Fitted with plate with holes for lubricant entry with G UNI ISO 228 1 threading 3 PRODUCT IDENTIFICATION A yell...

Страница 3: ...DUAL ACTING VERSION WITH RESERVOIR Fixing bracket Identifying tag ELECTRIC Minimum level Reservoir fill inlet G Lubricant outlet Rp Dual acting inlet outlet G Control cylinder Reservoir Level check d...

Страница 4: ...al posture or possible impact Do not install the pump submerged in liquids and or in aggressive environments Do not install the pump in environments where there are explosive or flammable mixtures Ens...

Страница 5: ...ype of lubricant Depending on these variables to achieve a proper supply to the delivery point it is always necessary to ensure that the pipeline pressure loss plus the pressure required at the lubric...

Страница 6: ...tighten all the fittings ensuring that there are no leaks The piston of the pumping element is worn out Replace the piston The delivery valve is blocked Replace the valve The pump does not dispense lu...

Страница 7: ...t disposal Upon demolition of the pump the identification label and any other document must be destroyed 11 ORDER INFORMATION Version WITH RESERVOIR for GREASE Part number Command Grease Characteristi...

Страница 8: ...050 523 20 6 736 28 97 196 7 7 280 11 02 75 2 95 3414022 511 20 1 661 26 02 192 3 5 276 10 86 75 2 95 3414014 Dual acting 511 20 1 761 29 9 192 3 5 276 10 86 75 2 95 Version WITHOUT RESERVOIR for OIL...

Страница 9: ...NBR gasket compatible lubricants Any residual lubricant inside that was used for assembly and testing is NLGI 0 grade 15 CONTRAINDICATIONS OF USE Compliance with the essential safety requirements and...

Отзывы: