background image

 

45221A 

Printed in Canada 

12-09-2014

 

 

 

OWNER`S MANUAL 

 

Escape 1400-I Insert 

 

 

US ENVIRONMENTAL PROTECTION 

AGENCY PHASE II CERTIFIED      

WOOD INSERT 

 
 

Verified and tested following 

ULC S628 and UL 1482 Standards by: 

 

 

 

Manufactured by : STOVE BUILDER INTERNATIONAL INC.

250, rue de Copenhague, Saint-Augustin-de-Desmaures (Quebec) G3A 2H3 

Tel.: 418 878-3040    Fax: 418 878-3001 

www.drolet.ca

 

 

READ AND KEEP THIS MANUAL FOR REFERENCE

 

This  manual  is  available  for  free  download  on  the  manufacturer’s  web  site.  It  is  a 
copyrighted  document.  Re-sale  is  strictly  prohibited.  The  manufacturer  may  update  this 
manual  from  time  to  time  and  cannot  be  responsible  for  problems,  injuries,  or  damages 
arising out of the use of information contained in any manual obtained from unauthorized 
sources. 

Содержание Escape 1400-I Insert

Страница 1: ...nt Augustin de Desmaures Quebec G3A 2H3 Tel 418 878 3040 Fax 418 878 3001 www drolet ca READ AND KEEP THIS MANUAL FOR REFERENCE This manual is available for free download on the manufacturer s web sit...

Страница 2: ...ay result in property damage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installations requirements in your area and the need to obt...

Страница 3: ...llation of the fresh air intake kit AC01298 sold separately 15 Section 3 0 Operation 16 3 1 Safety Information 16 3 2 Fuel 17 3 2 1 Simple Wood Moisture Test 18 3 3 Notes About First Firing 18 3 4 Lig...

Страница 4: ...4 Escape 1400 I Dimensions Faceplate fully extended toward the back Faceplate fully extended toward the front...

Страница 5: ...ed continuous stainless steel liner running from the flue collar to the top of the chimney termination Never remove parts that serve to insulate the zero clearance fireplace from combustible material...

Страница 6: ...al in the chimney Chimneys constructed outside of the home on an exterior wall should be avoided if possible especially in colder climates Outside chimneys may not draw as well and may downdraft due t...

Страница 7: ...7 Section 2 0 Installation 2 1 Minimum masonry opening clearances to combustibles and floor protector...

Страница 8: ...ible shelf in from of the insert is included in the calculation of the floor protector s dimensions IMPORTANT The masonry hearth should be at least 4 inches 102mm higher than the combustible floor in...

Страница 9: ...um floor protection for combustible floor materials as specified in this manual Floor protection to the front is to be measured from the fuel loading door opening 5 Drolet recommends that you install...

Страница 10: ...e acceptable however we recommend the use of a chimney liner to ensure satisfactory performance Slip connectors for continuous liners should also be installed Use Listed Chimney Liners S635 The connec...

Страница 11: ...on secured between the firebox and the convection air jacket Place the faceplate panels with the finished side down on a flat soft non abrasive surface and follow the installation instructions below H...

Страница 12: ...d side of each trim and then tighten the screws F to secure the trims Align the trim assembly L with the left and right edge of the faceplate and slowly slide it down over the faceplate Secure the tri...

Страница 13: ...tension N with the holes in each faceplate side panels and secure both assembly together using four 4 bolts D and nuts E provided see DETAIL C Center the insert into the fireplace opening and bring th...

Страница 14: ...the insert using the leveling bolts on each side of the convection air jacket until the faceplate is properly seated on the floor of the hearth extension Once the faceplate is in place secure the asse...

Страница 15: ...the metal rectangle A located on the side of the insert Choose the side that is best for your installation Then install the fresh air intake kit B using 4 screws C Secure the flexible pipe E non suppl...

Страница 16: ...pe lantern fuel kerosene solvents charcoal lighter fluid or inflammable liquids to start or freshen a fire in the insert Keep all such liquids well away from the insert while it is in use 6 All insert...

Страница 17: ...dows in the winter f A ventilation system is installed in the house 3 2 Fuel 1 Fuel for the insert must not be stored closer than the required clearances to combustibles and not in the space required...

Страница 18: ...ended to preserve the best quality finish Heating the insert too intensely on the first fire will dull and lighten the colour on overheated areas and cause smoke and odour to be emitted into the room...

Страница 19: ...t that point add cordwood fuel and continue to operate the draft control wide open until the fire is well established Once the firebox is hot the draft control can be partially closed by moving the kn...

Страница 20: ...ean efficiently burning fire Refuelling technique is important for good performance The best efficiency and performance from your insert can be achieved by adding partial loads of fuel and allowing th...

Страница 21: ...od and opened draft controls for a couple of hours Good burning techniques will result in clean glass Hand clean the glass only when the fire is out and the insert is cold A light film can usually be...

Страница 22: ...E BAFFLE MAY CAUSE UNSAFE AND HAZARDOUS TEMPERATURE CONDITIONS AND WILL VOID THE WARRANTY Contact your local municipal state or provincial fire authority for information on how to handle a chimney fir...

Страница 23: ...ge and replace if they are broken or damaged See Figure 3 3 for the firebrick layout Install the side back firebricks first and then the bottom firebricks Figure 4 2 Firebrick layout for Escape 1400 I...

Страница 24: ...a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replaced without disturbing the baffle Important Notes...

Страница 25: ...ith the fan turned off will also damage the fan The fan must not be overheated Do not disassemble the fan ALTERING OR TAMPERING WITH THE FAN WILL VOID THE WARRANTY 4 7 Removal instructions To remove y...

Страница 26: ...The EPA test procedure requires that a special type of wood be used and positioned inside the firebox in a manner that does not represent the way the firebox volume would normally be utilized using se...

Страница 27: ...nd labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation...

Отзывы: