Содержание EASTWOOD 1900

Страница 1: ...II CERTIFIED WOOD STOVE Verified and tested following ULC S627 and UL 1482 Standards by Manufactured by STOVE BUILDER INTERNATIONAL INC 250 de Copenhague Saint Augustin de Desmaures Qu bec G3A 2H3 Te...

Страница 2: ...y result in property damage bodily injury or even death Consult your municipal building department or fire officials about restrictions and installation requirements in your area and the need to obtai...

Страница 3: ...sting masonry chimney 24 FIGURE 2 2 2 C Brick Thimble 26 2 3 CHIMNEY CONNECTOR 27 2 4 DRAFT 28 2 5 OUTSIDE COMBUSTION AIR 29 2 6 THE ADVANTAGE OF INSTALLING A BLOWER FAN 30 SECTION 3 0 OPERATION 31 3...

Страница 4: ...5 CHIMNEY FLUE CLEANING 40 4 6 BAFFLE INSTALLATION FOR ESCAPE 1800 MODEL 40 4 5 SECONDARY AIR TUBE REPLACEMENT 42 SECTION 5 0 SPECIFICATIONS 43 DROLET LIMITED LIFETIME WARRANTY Erreur Signet non d fi...

Страница 5: ...t must serve as a supplementary heat source An alternative heat source should be available in the home if needed The manufacturer cannot be responsible for additional heating costs associated with the...

Страница 6: ...measured directly from the front of the stove must be a minimum of 48 1219 mm The stove must also be placed so as to maintain the minimum clearances to combustible walls specified for each type of con...

Страница 7: ...6 Figure 1 3 Clearances to combustible materials...

Страница 8: ...ion shield the clearances mentioned on the stove certification plate may be reduced as stated in the following table TYPE OF PROTECTION Reducing Clearances With Shielding Sides and Rear Back Top Sheet...

Страница 9: ...ection B 500 mm 20 po minimum C 25 mm 1 po minimum D Between 25 mm 1 po and 75 mm 3 po E 75 mm 3 po minimum F 450 mm 18 po minimum 1 Wall shielding 2 Non combustible spacers 3 Ceiling shielding 4 Comb...

Страница 10: ...2 Non combustible spacer 3 Fire proof support 4 Ceramic tile or equivalent non combustible material _____________________________________________________________________________ Graphic 4 A 25 mm 1 po...

Страница 11: ...10 Graphic 5 A 25 mm 1 po minimum 1 Combustible wall 2 Non combustible spacer 3 Brick Graphic 6 A 25 mm 1 po minimum 1 Combustible wall 2 Non combustible spacer 3 0 61 mm 0 024 sheet metal 4 Brick...

Страница 12: ...Please note that a floor protection is required with the pedestal models for spark and ash shielding but not for limiting floor temperatures from the radiant heat of the stove The stove was designed a...

Страница 13: ...se a chimney thermometer installed at a distance of approximately 18 inches on the flue pipe above the stove Flue gases should reach at least 350oF before you close the stove s primary air intake comp...

Страница 14: ...ory built chimney with insulation or any other material Insulation placed in this area could cause adjacent combustibles to overheat Do not use makeshift compromises during installation as they may be...

Страница 15: ...0 6 m See Figure 2 2 The minimum overall height of the chimney system measured from the stove top to the exterior termination cap of the chimney should be at least 12 3 66m A chimney which is too sho...

Страница 16: ...sories Wall support system If your chimney must rise along an outside wall you need to connect it to your stove through an adjacent wall For this type of installation the following items are normally...

Страница 17: ...16 Typical installation through the wall FIGURE 2 2 1 A Typical installation through the wall...

Страница 18: ...o locate the studs Use a spoke saw or jig saw to cut a hole remembering that you need to maintain a clearance of 2 inches between the chimney and any combustible materials For concrete walls cut a hol...

Страница 19: ...ure it into the wall studs TO complete the installation install an insulated tee plug below the wall support 6 You can start to add chimney sections We recommend that you also use locking bands to sec...

Страница 20: ...y extends more than 5 feet above the roof deck roof guys with telescoping legs and draw bands are required 8 Finally twist on your rain cap and you can head back inside 9 You are now ready to connect...

Страница 21: ...he following items are normally required Chimney An adequate number of chimney sections enough to go up to your roof A ceiling support kit with stove pipe adapter An attic insulation shield A roof fla...

Страница 22: ...go through the ceiling use a spoke saw or power jig saw to cut a hole remembering that you need a minimum 2 inch clearance between the chimney and any combustible materials Depending on whether you ha...

Страница 23: ...height of about 2 feet below the next ceiling level An attic insulation shield must be installed where a chimney passes from a lower living space into an upper living space or attic space It is design...

Страница 24: ...e roof deck Seal the joint between the shingles and the plate with silicone 8 Next slide the storm collar down the chimney until it contacts the flashing Tighten the nut and bolt and seal the collar t...

Страница 25: ...built thimble on construct your own brick thimble If you are using a masonry chimney it is important that it be built in compliance with the specifications of the Building Code in your region It must...

Страница 26: ...25 FIGURE 2 2 2 B Factory Built Thimble...

Страница 27: ...26 FIGURE 2 2 2 C Brick Thimble...

Страница 28: ...oward the chimney See Figure 2 3 B To insure a good draft the total horizontal length of the connector should never exceed 8 to 10 2 4 to 3 04 m In the case of vertical installation the total length o...

Страница 29: ...28 1 4 RISE PER FOOT FIGURE 2 3 B Minimum Slope Avoid 90 degree eblows We recommend that you use two 45 degree elbows instead...

Страница 30: ...atures 2 5 OUTSIDE COMBUSTION AIR It is recommended to install 5 outside air intake in the room where the stove is located or nearby The following are signs that a fresh air kit may be required Your s...

Страница 31: ...edistribute into a room the heat trapped at the back of your stove By forcing hot air toward the front the blower enables you to extend the radiation and convection power of your stove You can purchas...

Страница 32: ...FUEL WITHIN HEATER INSTALLATION CLEARANCES OPEN AIR CONTROL AND DAMPER WHEN FITTED BEFORE OPENING FIRING DOOR THIS STOVE IS NOT DESIGNED TO BE USED WITH THE DOOR OPEN THE DOOR MAY BE OPEN ONLY DURING...

Страница 33: ...llage or a back draft of flame or smoke into the room Never use gasoline type lantern fuel kerosene solvents charcoal lighter fluid or inflammable liquids to start or refresh a fire in the stove Keep...

Страница 34: ...sh in the unit Highly flammable items such as trash may ignite creosote in the chimney flue resulting in a chimney fire Never burn salt wood beach wood chemically treated wood or wood removed from sal...

Страница 35: ...ogs containing chemical additives burn a lot hotter and were designed for decorative fireplaces Decorative fireplaces generally have larger cooler and less air tight fireboxes Your E P A Drolet stove...

Страница 36: ...on while curing the stove Open one or more windows The odours can be smelled during the 3 or 4 first fires Never start your stove outside 3 4 LIGHTING A FIRE 1 Place enough crumpled balls of newspaper...

Страница 37: ...4 22 2 44 5mm from low position High Move Control against the R H side Table 3 4 Closing the draft control down too soon will lower combustion efficiency and may result in creosote build up in the ch...

Страница 38: ...prove combustion efficiency and to reduce the amount of creosote build up The best performance will be obtained by adding relatively small amounts of fuel to a well established ember bed and then oper...

Страница 39: ...g slow fires In general if the glass is not staying clean then the unit is being under fired Dirty glass may be self cleaned by burning a hot fire i e dry wood and opened draft controls for a couple o...

Страница 40: ...ons Make sure the fire is out and the stove is cold Lift the ash dump plug in the center of the firebox by hooking the poker through the loop on the cover and lifting up Push the ashes through the hol...

Страница 41: ...emely hot fire which could be hazardous Your E P A Drolet stove has been designed to reduce the amount of creosote produced Even so the chimney and any chimney connector should be inspected at least o...

Страница 42: ...6 1 A Baffle installation for Eastwood 1900 VERMICULITE BAFFLE A1 1 4 X 4 1 2 X 9 1 1 4 X 4 X 8 1 1 4 X 4 X 6 1 1 4 X 4 X 7 5 8 1 1 4 X 2 1 4 X 9 1 1 4 X 2 X 9 WHIT HOLE 1 1 2 2 2 2 3 4 3 3 5 3 3 3 3...

Страница 43: ...reverse order using a new cotter pin The cotter pin is a hammerlock style and locks into place by hitting the head sharply with a hammer 5 Note that any tube can be replaced without disturbing the baf...

Страница 44: ...testing The EPA test procedure requires that a special type of wood be used and positioned inside the firebox in a manner that does not represent the way the firebox volume would normally be utilized...

Страница 45: ...lacement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any part or unit after ins...