Heat Commander Furnace Installation and Operation Manual
83
PART C – FEATURES AND SAFETY
13 General information
13.1 Appliance performance
(1)
Fuel type
Dry cordwood
Recommended heating area
[*]
1,000 to 2,500 ft² (93 à 232 m²)
Firebox volume
3.6 ft³ (0.102 m³)
Maximum burn time
[*]
10 h
Maximum input capacity (dry cordwood)
(2)
310,000 BTU
Overall heat output rate (min. to max.)
(3)
19,354 BTU/h to 47,052 BTU/h (5.6 kW to 13.8 kW)
Nominal heat output
at 15lb/ft³ fuel loading density
75,000 BTU/h
Average overall efficiency
(4)
76.6 % (HHV)
(5)
Delivered heat output rate (min. to max.)
(7)
13,297 BTU/h to 42,234 BTU/h (3.9 kW to 12.4 kW)
Average delivered efficiency
(8)
60.7 % (HHV)
(5)
Optimum efficiency
(9)
83.2% LHV at minimum burn rate
Average particulate emissions rate
(10)(11)
0.095 lb/mmBTU (0.041 g/MJ)
Average CO
(12)
8.78 lb/mmBTU (3.78 g/MJ)
Average electrical power consumption
(13)
330 W
[*]
Recommended heating area and maximum burn time may vary subject to location in home, chimney draft,
heat loss factors, climate, fuel type and other variables. The recommended heating area for a given
appliance is defined by the manufacturer as its capacity to maintain a minimum acceptable temperature
considering that the space configuration and the presence of heat distribution systems have a significant
impact in making heat circulation optimum.
(1)
Values are as measured per CSA B415.1-10, except for the recommended heating area, firebox volume,
maximum burn time and maximum input capacity. Performances based on a fuel load prescribed by the
standard at 10 lb/ft³ and with a moisture content between 18% and 28%.
(2)
Input value at 10lb/ft³ fuel loading density and dry energy value of 8,600BTU/lb.
(3)
Overall: Radiated and delivered heat together at10lb/ft³ fuel loading density over one total burn cycle.
(4)
Efficiency based on delivered heat when allowing cycling from high to low burn to simulate thermostat demand.
(5)
Higher Heating Value of the fuel.
(6)
Lower Heating Value of the fuel.
(7)
Delivered: Remotely provided to other rooms through ducting at 10 lb/ft³ fuel loading density over one total
burn cycle.
(8)
Efficiency based on radiated and delivered heat when allowing cycling from high to low burn to simulate
thermostat demand.
(9)
Optimum overall efficiency at a specific burn rate (LHV).
(10)
Based on delivered heat output.
(11)
This appliance is officially tested and certified by an independent agency.
(12)
Carbon Monoxide. Based on overall heat output at 10lb/ft³ fuel loading density.
(13)
Unless st
ated otherwise, measures were taken directly at the main power source and include all electrical
components present in the appliance.
Содержание DF02003
Страница 2: ......
Страница 24: ...Install the cover on the part B of the assembly and secure it with 16 screws C...
Страница 35: ...Heat Commander Furnace Installation and Operation Manual 35 7 1 1 Electrical Diagram...
Страница 73: ...Heat Commander Furnace Installation and Operation Manual 73 12 Exploded diagram and parts list...
Страница 74: ......
Страница 75: ...Heat Commander Furnace Installation and Operation Manual 75...
Страница 76: ......
Страница 77: ...Heat Commander Furnace Installation and Operation Manual 77...
Страница 78: ......
Страница 79: ...Heat Commander Furnace Installation and Operation Manual 79...
Страница 85: ...Heat Commander Furnace Installation and Operation Manual 85 13 2 1 Technical data...
Страница 86: ......
Страница 91: ...Heat Commander Furnace Installation and Operation Manual 91...
Страница 92: ......