Exhaust blowers that are in a fuel storage room should be installed so as not to create
negative pressure in the room where the solid fuel appliance is located.
A fresh air supply may be necessary to prevent furnace from rejecting products of
combustion into the house. The indications used to determine if an additional fresh air supply
is necessary are not appropriate for all the situations. When in doubt, it is recommended to
install a fresh air supply.
A fresh air supply may be needed if:
-
Solid fuel units present anomalies, such as irregular draft, smoke return, bad combustion,
and/or reversed draft (whether there is combustion or not);
-
Existing units such as a stove, a furnace or fireplace release odours, heat badly, cause
smoke returns, or reversed draft (whether there is combustion or not );
-
The opening of a window, even slightly, in calm weather (windless), eliminates every
problem mentioned above ;
-
The house is equipped with a tight vapour/air barrier and adjusted windows, and/or is
equipped with an interior air mechanical evacuation device ;
-
There is excessive condensation on the windows in winter; and
-
The house is equipped with a ventilation system.
If, according to these symptoms or other similar ones, there is insufficient combustion air, it is
necessary to ensure an additional combustion air supply (see
Section 6:
Air Supply in
conventional houses
).
9.8 Ash drawer
Your furnace is equipped with an ash drawer to collect ashes produced by the combustion
of wood. The ash drawer is provided with one (1) wing nut to hold the door in a close position.
Operating the furnace with the ash drawer open may cause overfiring and damage the
furnace.
The drawer must be emptied weekly.
9.9 Prolonged power outage
To reduce the risk of overheating during a prolonged power outage (more than 10 minutes),
the combustion air controls will be closed automatically. If your furnace is equipped with the
optional filter, remove the air filter to improve the circulation of air around the combustion
chamber of the furnace. Do not load the furnace more than 50 percent of its capacity to
prevent the risk of overheating,
Содержание DF02003
Страница 2: ......
Страница 24: ...Install the cover on the part B of the assembly and secure it with 16 screws C...
Страница 35: ...Heat Commander Furnace Installation and Operation Manual 35 7 1 1 Electrical Diagram...
Страница 73: ...Heat Commander Furnace Installation and Operation Manual 73 12 Exploded diagram and parts list...
Страница 74: ......
Страница 75: ...Heat Commander Furnace Installation and Operation Manual 75...
Страница 76: ......
Страница 77: ...Heat Commander Furnace Installation and Operation Manual 77...
Страница 78: ......
Страница 79: ...Heat Commander Furnace Installation and Operation Manual 79...
Страница 85: ...Heat Commander Furnace Installation and Operation Manual 85 13 2 1 Technical data...
Страница 86: ......
Страница 91: ...Heat Commander Furnace Installation and Operation Manual 91...
Страница 92: ......