Drolet DB03129 Скачать руководство пользователя страница 1

Printed in Canada

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION REQUIREMENTS IN 
LOCAL AREA.

READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS WOOD STOVE. FAILURE TO FOLLOW THESE 
INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE, BODILY INJURY OR EVEN DEATH.

READ AND KEEP THIS MANUAL FOR REFERENCE

46108A

2021-10-26

Installation and Operation Manual

 ESCAPE 2100

(DB03129 and DB03131 models)

MOBILE

HOME

Safety tested according to ULC S627, 

UL 1482 and UL 737 standards by an 

accredited laboratory.

ENGLISH

US Environmental Protection Agency 

phase II certified wood stove compliant 

with 2020 cord wood standard

Содержание DB03129

Страница 1: ...ESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH READ AND KEEP THIS MANUAL FOR REFERENCE 46108A 2021 10 26 Installation and Operation Manual ESCAPE 2100 DB03129 and DB03131...

Страница 2: ......

Страница 3: ...this stove and the chimney that it is connected to It is also highly recommended to inform your home insurance company Please read this entire manual before installing and using this stove A primary...

Страница 4: ...e 14 3 4 Compressed Wood Logs 14 3 5 Drying Time 14 4 Operating the Stove 15 4 1 The Use of a Fire Screen 16 4 2 Blower Operation 16 5 Burning Wood Efficiently 17 5 1 First Use 17 5 2 Lighting Fires 1...

Страница 5: ...ht 36 9 3 Chimney Location 36 9 4 Supply of Combustion Air 37 9 5 Chimney Connector 38 Appendix 1 Optional Fresh Air Intake Kit Installation 40 Appendix 2 Optional Fire Screen Installation 41 Appendix...

Страница 6: ...Page 6 Installation and Operation Manual Escape 2100 ENGLISH CERTIFICATION PLATE...

Страница 7: ...efore opening the loading door NEVER USE GASOLINE LANTERN FUEL NAPHTHA FUEL OIL MOTOR OIL KEROSENE CHARCOAL LIGHTER FLUID OR SIMILAR LIQUIDS OR AEROSOLS TO START A FIRE IN THIS STOVE KEEP ALL SUCH LIQ...

Страница 8: ...Recommended heating area and maximum burn time may vary subject to location in home chimney draft heat loss factors climate fuel type and other variables The recommended heated area for a given applia...

Страница 9: ...y ULC S627 10 North south ends of the logs visible East west sides of the logs visible 11 Mobile homes Canada or manufactured homes USA The US Department of Housing and Urban Development describes man...

Страница 10: ...24 610mm Figure 1 Top view Figure 2 Front view 22 3 4 578mm 13 1 2 344mm 31 1 4 794mm 34 1 2 876mm 33 7 8 861mm 12 3 8 313mm 31 7 8 810mm 24 1 8 613mm 16 406mm 20 1 8 510mm 12 7 8 326mm 5 16 8mm 3 16...

Страница 11: ...level the coal bed and put six logs in the firebox of approximatively 4 x4 or 3 x3 Add the load in an East West configuration divided in 3 columns 2 smallest logs in the back 2 logs in the middle and...

Страница 12: ...emperature glass Ceramic glass cannot be recycled in the same way as normal glass so it should not be disposed of with regular household products Disposal at a waste management center is recommended 2...

Страница 13: ...sed is in the correct moisture content range of 15 to 20 Refer to the following section of suggestions on preparing fuelwood and judging its moisture 3 Fuel Good firewood has been cut to the correct l...

Страница 14: ...es loading the stove very difficult The most common standard length of firewood is 16 400 mm 3 3 Piece Size Firewood dries more quickly when it is split Large unsplit rounds can take years to dry enou...

Страница 15: ...eces are big Firewood dries more quickly when stacked outside in a location exposed to sun and wind it takes much longer to dry when stacked in a wood shed Firewood with a moisture content of 15 to 20...

Страница 16: ...lower can be installed on this stove It is optional and is sold separately See Appendix 9 Exploded Diagram and Parts List for genuine part number The blower must be installed on the back of the stove...

Страница 17: ...to crumple 5 to 10 sheets of newspaper and place them in the firebox and hold them in place with ten pieces of kindling wood The kindling should be placed on and behind the newspaper Then add two or t...

Страница 18: ...of zone heating wood burning Wood heaters don t have a steady heat output It is normal for the temperature to rise after a new load of wood is ignited and for its temperature to gradually decrease th...

Страница 19: ...the appliance produces a heat surge This heat surge is pleasant when the room temperature is cool but can be unpleasant when the room is already warm Therefore it is best to let each load of wood bur...

Страница 20: ...in fall weather will overheat the space Otherwise the combustion rate will have to be reduced to a minimum and the fire will be smoky and inefficient Here are some suggestions for building fires suit...

Страница 21: ...is not necessarily an indication of efficient operation It is preferable to build a smaller fire that will provide three or four hours of heating than to fully load the firebox for a much longer burn...

Страница 22: ...ormal conditions the door glass should stay relatively clear If the firewood is dry enough and the operating instructions in this manual are followed a whitish dusty deposit will form on the inner sur...

Страница 23: ...dhesive backed woven fibreglass The gasket must be centred on the edge of the glass 1 Follow the steps of the previous section to remove the glass 2 Remove the old gasket and clean the glass thoroughl...

Страница 24: ...t groove 3 Apply a bead of approximately 3 16 5 mm of high temperature silicone in the door gasket groove Starting from the middle hinges side press the gasket into the groove The gasket must not be s...

Страница 25: ...the hotter the fire the less creosote is deposited and weekly cleaning may be necessary in mild weather even though monthly cleaning may be enough in the coldest months Contact your local municipal or...

Страница 26: ...WALL CEILING AND ROOF MUST BE MAINTAINED 7 2 Regulations Covering Stove Installation When installed and operated as described in these instructions this wood stove is suitable for use as a freestandin...

Страница 27: ...e than the minimum clearance figures given The clearances to combustible walls may be slightly different in Canada and the U S A and may also differ depending on whether single or double wall flue pip...

Страница 28: ...2 mm E 24 632 mm 24 632 mm F 18 457 mm 18 457 mm F 17 451 mm 17 451 mm 8 1 1 With Heat Shield AC02710 or AC0276214 APPLIANCE CLEARANCES WITH DOUBLE WALL PIPE CONNECTOR DISTANCES13 FROM DOUBLE WALL PIP...

Страница 29: ...13 340 mm C 2 64 mm 2 64 mm F 13 337 mm 13 337 mm L 74 1 880 mm 74 1 880 mm 8 1 4 Inside an Alcove APPLIANCE CLEARANCES WITH DOUBLE WALL PIPE CONNECTOR DISTANCES16 FROM PIPE CONNECTOR WITH DOUBLE WAL...

Страница 30: ...E 15 403 mm 15 403 mm C 3 76 mm 3 76 mm F 13 349 mm 13 349 mm 8 2 Floor Protection This stove is designed to prevent the floor from overheating However it must be placed on a non flammable surface to...

Страница 31: ...y the instructions carefully Some regions may have different regulations Consult the local building code or contact the fire department for restrictions inspection and installation requirements in the...

Страница 32: ...ance 20 500 mm C Minimum space behind the shield 1 25 mm In Canada 21 mm D Clearance along the bottom of the shield minimum 1 25 mm and maximum 3 75 mm E Minimum clearance along the top of the shield...

Страница 33: ...ible material on non combustible board spaced out at least 1 25 mm by non combustible spacers 50 18 457 mm 33 24 610 mm Ceramic tiles or equivalent non combustible material on non combustible board wi...

Страница 34: ...least 5 130 mm Canada only or no more than 7 180 mm is permitted if it allows the proper venting of combustion gases and that such application is verified and authorized by a qualified installer Othe...

Страница 35: ...g must be installed and sealed with silicone adhesive 9 1 3 Masonry Chimney The stove may also be connected to a masonry chimney provided the chimney complies with the construction rules found in the...

Страница 36: ...ulate fewer creosote deposits and will be unaffected by cold temperatures or harsh winds Outside chimneys will lead to cold back drafting when there is no fire in the stove slow kindling of new fires...

Страница 37: ...supply of combustion air for a wood stove is from the room in which it is installed Room air is already preheated so it will not chill the fire and its availability is not affected by wind pressures...

Страница 38: ...s straight up from the stove to the base of the chimney with no elbows Straight assemblies are less likely to cause problems like smoke roll out when the door is opened for loading They are also more...

Страница 39: ...tallation must allow expansion elbows in assemblies allow for expansion straight assemblies should include an inspection wrap with one end unfastened or a telescopic section Minimum upward slope towar...

Страница 40: ...tallation of a fresh air intake kit A and an insulated fresh air intake pipe HVAC type must meet ULC S110 or UL 181 class 0 or class 1 B sold separately Refer to air intake kit installation instructio...

Страница 41: ...ed 1 Open the door 2 Hold the fire screen by the two handles and bring it close to the door opening 3 Lean the upper part of the fire screen against the top door opening making sure to stove the top f...

Страница 42: ...e stove 1 Remove the backplate by cutting the knockouts with pliers MICRO JOINT KNOCKOUT 2 Screw the blower A in place using the screws B included in the installation manual Ensure that the blower s p...

Страница 43: ...er It allows the fan to operate only when the stove is hot enough See the instructions provided with the thermodisc for more details Screw the thermodisc C with the screws D provided on the back of th...

Страница 44: ...llation and Operation Manual Escape 2100 ENGLISH Appendix 5 REMOVING THE DECORATIVE PANELS To remove the decorative panels A remove the screws B and push forward on the panel to unhook it from the sup...

Страница 45: ...Page 45 Installation and Operation Manual Escape 2100 ENGLISH Appendix 6 LOG RETAINERS INSTALLATION 1 2 3 2 MIN 2 MIN...

Страница 46: ...hen lift and insert the left end of the tube into the rear left channel 2 Align the notch in the left end of the tube with the key of the left air channel hole Using a Wise grip hold the tube and lock...

Страница 47: ...Page 47 Installation and Operation Manual Escape 2100 ENGLISH Note that secondary air tubes A can be replaced without removing the baffle board B and that all tubes are identical A B...

Страница 48: ...Page 48 Installation and Operation Manual Escape 2100 ENGLISH Appendix 8 MOBILE HOME INSTALLATION Screw the base on the floor with the proper hardware...

Страница 49: ...H Appendix 9 EXPLODED DIAGRAM AND PARTS LIST 43 2 1 3 9 10 4 5 8 6 DETAIL A 7 40 35 31 34 36 37 38 39 33 32 34 12 18 11 20 22 21 14 15 16 13 17 42 41 23 24 27 28 26 29 30 19 A 45 44 46 27 27 27 28 28...

Страница 50: ...ASS FRAME 1 12 PL70832 RIGHT GLASS FRAME 1 13 30429 3 8 NICKEL COIL HANDLE 1 14 30506 SCREW PAN TORX TYPE F 1 4 20 X 1 BLACK 1 15 30206 ZINC WASHER 5 16 ID X 3 4 OD 1 16 SE70904 AIR DAMPER ASSEMBLY 1...

Страница 51: ...0 SE46108 USER MANUAL ESCAPE 2100 1 41 AC01336 5 FRESH AIR INTAKE KIT FOR WOOD STOVE ON PEDESTAL 1 42 24096 ROUND CAST IRON ASH PLUG 1 43 PL70838 ASH PAN 1 44 PL70879 BRUSHED NICKEL TOP DOOR MOLDING D...

Страница 52: ...nufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect The manufacturer may at its discretion fully discharge all obligations wi...

Страница 53: ......

Страница 54: ...nal com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to tim...