background image

 

 

 

 

Aston Shower Commode Chair 

Owner’s Handbook 

 

 

 

Содержание Ason Shower Commode

Страница 1: ...Aston Shower Commode Chair Owner s Handbook...

Страница 2: ...athroom environment Personal Safety Read these instructions carefully before use Check all components are secured before use Only use on level ground When stationary apply the brakes on the wheels Ens...

Страница 3: ...addition the following parts Z33302 16BL Armpad are available for the 24 self Z33303 16 Potty with Lid propel version Z33304 16 Castor Braked Z33310 16 Quick Release Pin Z33305 16 Footrest RHS Z33311...

Страница 4: ...ring the footrest is swung back Swing the footrest towards the front of the chair until it locks in position Repeat for the other footrest and adjust the footplate height and angle if required see ins...

Страница 5: ...Installation and Removal Follow the Assembly instructions for details on how to install the footrests To remove the footrests swing out the footrest and lift up to remove Footplate Adjustment 1 To ad...

Страница 6: ...l interfere with the rear wheels Castor Adjustment The height of the chair and seat can be altered by adjusting the castor height To adjust the castor height remove the E clip or nut and bolt arrowed...

Страница 7: ...cleaned and disinfected manually or in an autoclave It should be cleaned after each use Replacement potties are available from Drive Medical under product code Z33303 16 Seat Operation and Removal Th...

Страница 8: ...els when installed 3 Install the two brackets which receive the axles for the 24 wheels so that the rear castors will be approximately 3mm from the ground when the 24 wheels are added 4 The wheels hav...

Страница 9: ...the 24 rear wheels are installed the chair can be propelled by either the attendant or the chair occupant If the attendant is propelling the chair they should propel the chair using the push handle a...

Страница 10: ...ength 87cm 34 Depth 43cm 17 Width 56cm 22 Width 46cm 18 Height 97 102cm 38 40 Height 48 53cm 19 21 Backrest Height 47cm 18 5 from seat Aperture 17 W x 27cm D 7 W x 11 D Armrest Height 70 75cm 28 30 Un...

Страница 11: ...ovided that the device has been maintained in line with manufacturer s recommendations If the device is used in a multi user environment such as a nursing home or hospital then service life may be red...

Страница 12: ...n supply parts or replace the device This warranty does not cover device failure due to owner misuse or negligence or normal wear and tear The warranty does not extend to non durable components such a...

Отзывы: