User Manual 

 

PRISMA TOUCH 76 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage 110V-120V 

 

 

 

Содержание PRISMA TOUCH 76

Страница 1: ...User Manual PRISMA TOUCH 76 Voltage 110V 120V ...

Страница 2: ...User Manual RANGE HOOD PRISMA TOUCH 76 2 1 FOR YOUR SECURITY 3 2 EXTRACTOR DESIGN 3 3 WHEN CLEANING THE EXTRACTOR 6 4 CHANGING THE BULBS 7 5 INSTALATION 8 6 CIRCUIT DIAGRAM 10 7 TECHNICAL DATA 11 ...

Страница 3: ...sonnel Clean the filter cartridge regularly once a month The extractor is not allowed to be used on a solid fuel stove wood coal etc These extractors have been designed for private use in the home for constant product improvements We reserve the right to make changes in its technical functional or aesthetic characteristics as results of technical developments These kitchen extractors were designed...

Страница 4: ... any other button except the one of the power supply 3 Intensity button has 3 positions Fast Medium and Slow Turn on turn off Press the power button it will turn on with the digital display Press the slow button the display will show the letter L the light and motor will start to work slowly Then press the slow button and both the light and digital display will turn off the motor cancels all previ...

Страница 5: ...or and 12 00 will flash on the display Note For minutes the highest number is 59 Larger numbers are invalid Press Clock button to recognize it When the backlight and the indicator light go off the hours and minutes have already been set LOW SPEED For simmering that does not produce much steam Ventilate the kitchen AVERAGE SPEED For standard meals HIGH SPEED When large amounts of steam and smoke wi...

Страница 6: ...ANING FILTER CARTRIDGE Clean the filter every month to prevent fire hazard The filter collects grease and dirt as it is an element that plays an important role in the efficiency of the extractor It can be flammable if saturated with grease residues Clean with commercially available home product rinse properly and dry Cleaning can be done in your dishwasher by placing the filter in up position do n...

Страница 7: ...ide the extractor and take control when you change them DANGER Disconnect the extractor before servicing Remove the filter Place the new carbon filter into the blower of the extractor inside the surface and then put it directly Repeat the same operation for each of the filters Arrange the filter again 4 CHANGING THE BULBS Disconnect or shut off the extractor before beginning maintenance MODEL USIN...

Страница 8: ...t to the outside All our appliances have the option to operate in re circulation with no outlet to the outside Under these circumstances add a charcoal filter activator which will catch odors See instructions on page 7 This filter is available through your dealer under the reference number indicated on the nameplate See inside the extractor MOUNTING Pre assembly recommendations The extractor must ...

Страница 9: ...g of the glass See pic 3B Drill 2 holes of 8 mm in a suitable place according to the second plate see fig 4A place two screws in the direction of the plate see fig 4A then remove the internal chimney at a suitable height Put the inner chimney on the second plate and tighten the two screws see pic 4B MODEL WITHOUT GLASS To install on the wall every 100 mm drill 3 holes whose diameter is 8 mm in a s...

Страница 10: ...CTION This appliance is supplied with a H05V VF power cable with 3 cores of 0 75m2 2 phases ground and must be connected to 110V single phase mains using a plug and switch complying with CEI83 standard which must be easily accessible Once it is mounted or a bipolar double isolator switch with contact opening of at least 3 mm This double bipolar isolator will also be required if the outlet is not a...

Страница 11: ...ions Reach electrical equipment that is no longer working yet suitable disposal center Note The manufacturer reserves the right to make changes to the specifications and design of the product Power Input 140W 180W 220W Voltage Range 110 127V 220 240V 110 127V 220 240V 110 1 27V Range Frequency 50HZ 60 HZ 50HZ 60 HZ 50HZ Current Rating 0 8 1 5A 0 8 1 5A 0 8 1 5A ...