PREPARATIONS FOR USE
Remove the front panel (item 5 illustration 1) by lifting it up-and-out.
Remove the foot-pedal console (items 6 illustration 1) by lifting it up and folding it out to the side (see illustration 2).
Solvent drums for the left side of the unit:
Two drums are needed, one drum that is empty, and one drum full of solvent. Both drums must be of the same size, and
they must meet the requirements described under chapter PERMITTED SOLVENT DRUMS. Both drums must be
clean on the inside and they must not contain any solids or other objects that could be sucked into the pumps when
running.
Drum plugs
There are several types of solvent drums on the market, each with different diameter of the opening. With the unit, a card
board box with a selection of tapered plugs is supplied (see illustration 3). Select the plug that fit well into the opening of
the drums, and fit them onto the drum adaptor of the hoses (see illustration 4).
Solvent fill-up on the left side of the unit:
Use one empty drum and another drum of the same size full of clean solvent.
Place the empty drum to the left underneath the unit (item 2 illustration 2). Insert the group of hoses containing the drain
hose from the sink into this drum (item 4 illustration 2). Make sure that the hoses are properly led well down into the
drum, and that the opening is well sealed by the tapered plug.
Take the second drum, the one full of solvent, and pour half of its contents directly into the gun cleaner’s sink (item 2
illustration 1). The solvent that is poured in will drain into the drum underneath the gun cleaner. Make sure to have the
ventilation running during this procedure.
Place the second drum, now half full, on the floor on the right-hand side of the first drum (item 3 illustration 2). Insert the
second group of hoses containing a white hose into this drum (item 5 illustration 2). Make sure that the hoses are
properly led into the drum all the way down to the bottom, and that the opening is well sealed by the tapered plug.
The solvent system is now filled-up. Both drums should be half full. The left-hand drum, contains the solvent that will be
recirculating for the automatic wash cycle, and the right-hand drum contains clean solvent for rinsing. The contents of
the right drum will gradually be used up and transferred to the left drum.
Water
Fill the filtrate container (item 7 illustration 2) up to 100mm (4”) under the upper edge with clean water.
Operating instructions
Operating instructions should be formulated on the basis of this manual and translated into the language spoken by the
employees. It should always be available close to the machine. To avoid confusion, the employees must be informed
about the solvent currently being used in the machine.
SERVICE
Weekly:
Remove the strainers at the bottom of the automatic washer (item 2 illustration 5) and clean it, do not forget to
re-fit it !
Monthly:
Remove the five nozzles in the automatic washer and clean them with clean solvent. (see illustration 8).