CESAR 1312 (E)
Troubleshooting and Customer Support
6-5
CESAR™ 1312 Generator
•
No or incorrect power or input voltage
•
The unit set for incorrect tuning control
•
Incorrect parameters set for the unit
Incorrect Input Voltage
Ensure that the input voltage to the unit is within specifications (see
Ensure that the input connector is connected to the correct pins, see
the CESAR Generator” on page 5-3
).
Once you have verified that you have the correct input voltage and
connection, disconnect the input voltage and reconnect it. The capacitors
should initialize, creating a high frequency for approximately 5 seconds and
then stop.
Improper Impedance Range
A variety of problems can occur if the specifications of the connected matching
network do not correspond to basic application parameters such as
impedance, current, voltage, phase angle, forward power, and reflected
power. These problems can include:’
•
Difficulty igniting plasma
•
Difficulty achieving expected minimum reflected power with manual or
automatic tuning by the matching network
•
Arcing inside the matching network
You can change the impedance range of the Variomatch by changing the
Variomatch tap settings. For information on checking the Variomatch
impedance range and changing the tap settings, see the Variomatch manual.
Impedance plots for Variomatch tap settings are available through the
Dressler website:
For any additional information or questions, contact Customer Support.
Improper RF Connection or Cabling
Proper operation requires low impedance RF connections between the
generator, match network, and load. In most situations, coaxial cable of an
appropriate diameter is sufficient for the RF connections. Additionally, make
the following checks:
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...