4
You may select values between 0 V and 4000 V using a combination of
the
Increm Auto
key and the
RF POWER
rotary dial.
9. Press
Ok
to confirm.
10. Press the desired
Control by
setting:
4
Front Panel
defaults to front panel control.
4
User Port
defaults to
User Port
control.
11. If your CESAR generator has an RS-232 port, select the desired
RS232
Baud Rate
value using the
RF POWER
rotary dial knob.
12. Press
Ok
to confirm.
13. If your CESAR generator has an RS-232 port, select the desired
RS232
Protocol
.
4
AE BUS
is the standard protocol for CESAR generators.
4
Dressler
is available for compatibility only.
14. Press
Ok
to confirm.
15. Press the
Exit
soft key.
16. Press the
Execute
soft key.
Setting and Using Preset Generator Settings for Different
Applications
You can set the various front panel functions to meet your specific process
needs, and you can store up to five presets (1 through 5) for five different
applications. The presets store all settings in the program menu except pulse
input configuration and device configuration. Preset 0 is reserved for factory
settings and can be accessed read-only.
To Store a Preset Using the CESAR Generator Front Panel:
1. Set all of the desired parameters using the front panel program menu (see
“Using the Front Panel Program Menu” on page 5-26
2. After you have made the appropriate program menu selections, you will
have the option to
Execute
,
Store Preset
, or
Quit
.
3. Press
Store Preset
. The settings for this particular preset will flash on the
front panel.
To Erase a Preset Using the CESAR Generator Front Panel:
1. Go to the preset number you wish to erase. (When you select a number,
the settings for each particular preset will flash on the front panel).
2. Press
Quit
.
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...