5-14
Installation, Setup, and Operation
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
“Troubleshooting Guide” on page 6-2
b. Is the plasma stable (that is, is the plasma producing a constant glow)?
If not, see
“Troubleshooting Guide” on page 6-2
.
9. If you have a matching network connected, did the capacitors begin to
move? If not, see
“Matching Network Troubleshooting” on page 6-2
.
10. Vary the chamber conditions according to your process requirements, and
verify that the CESAR generator can cover the required load impedance
range.
Congratulations, you have successfully installed and operated the CESAR
generator.
Operating the CESAR Generator for the First Time Using the
Front Panel
You can operate the CESAR generator using full front panel control or remote
control with partial front panel control. This section describes full front panel
control operation. For partial control (Remote Control Override), see
Remote Control Override” on page 5-37
.
To Operate the CESAR Generator for the First Time Using the Front Panel:
1. Ensure that the
User Port
interlock signal is satisfied.
4
If you have a 25-pin
User Port
, verify that there is external contact
closure between pins 10 and 23 (
INTERLOCK LOOP
). See
for more information.
4
If you have a 15-pin
User Port
, verify that there is external contact
closure between
Interlock
pins 1 and 2 (see
).
2. Power on the system by turning the front panel
ON/OFF
switch clockwise
to a vertical position. The initial front panel screen will display the CESAR
generator model name, the operating frequency, the maximum RF power,
and the software version. After five seconds, the display will change to a
standard operation screen.
3. Listen to ensure the fans are rotating.
4. Press the
RF POWER ON
key on the front panel.
5. Use the
RF POWER
rotary dial knob to increase the RF power to a desired
level.
6. Check the load. If the load is a plasma:
a. Is the plasma lit? If not, you may have a faulty connector or too little
“Troubleshooting Guide” on page 6-2
b. Is the plasma stable (that is, is the plasma producing a constant glow)?
If not, see
“Troubleshooting Guide” on page 6-2
.
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...