4-68
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
17
frequency
tuning
parameters
Sets the parameters for frequency
tuning.
Send three data bytes, least significant
byte first.
• Bytes1 and 2 specify the maximum
frequency in kHz (this value is
ignored when byte 3 is set to 0).
• Byte 3 selects the control mode for
frequency shift tuning (FST):
4
0 = No FST (frequency as defined
with command
18
)
4
1 = Integral, phase positive
4
2 = Integral, phase negative
4
3 = Proportional, phase positive
4
4 = Proportional, phase negative
If FST is active (modes 1 through 4), the
frequency set with command
18
is used
as the minimum frequency limit. Ensure
that this frequency is less than the
maximum frequency before command
17
is used.
Note:
This command is not available on
generators with fixed frequency.
For more information, see
.
Read back with
187
.
3
1
(CSR only)
Table 4-16. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...