background image

ENIGMA-X / SPARKLE manual Ver 6  Rev 4  07/2016

A

Guide Rail Brackets

 must be firmly 

attached to the wall. 

Installation into a 

stud is strongly recommended.
All of the guide rail bracket set 
screws must be tightened.

B

Thread Lock must be applied to both 
stopper set screws. 
Panel-side stopper must be installed 
into the pre-drilled stopper hole in 
the upper guide rail.
Door-side stopper must be installed 
at the proper position to stop the 
door from contacting the wall.

E

Bumper Vinyl Seal must be installed on 
the closing edge of the door glass

D

Roller Guards must be postioned and 
secured  within 1/16” of Upper Guide Rail

F

The Guide Block

 

must be screwed to the 

threshold 

and installed square to the panel 

glass and door glass. Installing the guide 
block crooked may damage the bottom edge 
of the door glass and lead to breakage.

C

Roller Wheel Safety Set Screws must 
be re-tightened after installation 

A

B

D

F

E

C

B A

DOOR

PANEL

Right hand door installation shown as an example

PLEASE READ THE ENCLOSED INSTALLATION 
MANUAL FOR DETAILS REGARDING PROPER 
INSTALLATION. 
THE LATEST VERSION OF THE INSTALLATION 
MANUAL IS AVAILABLE TO VIEW OR PRINT 
ON DREAMLINE.COM

!

IMPORTANT INFORMATION 
REGARDING THE INSTALLATION 
OF THIS SHOWER DOOR

Содержание ENIGMA-X SHDR-61487610-07

Страница 1: ...regarding installation please contact our technical support specialists Monday through Friday 8 00 AM 7 00 PM EST at Phone 1 866 731 2244 Fax 1 866 857 3638 or e mail our technical support group at S...

Страница 2: ...sing edge of the door glass D Roller Guards must be postioned and secured within 1 16 of Upper Guide Rail F The Guide Block must be screwed to the threshold and installed square to the panel glass and...

Страница 3: ...solid and will be able to support the total weight of the unit Also make sure the walls are at right angles Irregular installation surface level or improper angle of side walls will result in serious...

Страница 4: ...x If any parts are damaged or missing please contact DreamLine for replacement The shipping boxes may contain extra parts not used in your model configuration NOTE Retain these installation instructio...

Страница 5: ...ass 1pc 15 Anti splash threshold 1pc 06 Handle 1pc 16 Threshold cap 1pcs 07 Glass bracket 2pcs 17 1pc 08 Guide rail bracket 2pcs 18 2pcs 09a Wall anchor 3 8 10mm 2pcs 19 Wall bracket 1pc 09b Wall anch...

Страница 6: ...s 21 Small Stationary glass bracket 1pc 11 Allen Wrench 3 4 5mm 1 each 22 Small Stationary glass bottom bracket 1pc 14 Anti Water Strip 1pc 23 Small Stationary Glass 1pc 18 ST4 2x55 Truss Head Screw 1...

Страница 7: ...al rail is shorter than the model width by design Cut the Upper Guide rail 03 from the door end only which is the end that is farther from the Glass bracket 07 holes The length to cut off will be L Mo...

Страница 8: ...each end of the Upper guide rail 03 and secure them temporarily using the 4mm allen wrench 11 Install the panel end stopper into the pre drilled stopper hole in the Upper Guide Rail Fig 3 3 Slide the...

Страница 9: ...as shown in Fig 5 This bracket will be repositioned when the Small Stationary glass 23 is installed See Fig 5 for details 5 If the width of your model is 72 and includes the Small Stationary glass 23...

Страница 10: ...ion it against the wall Please note that the Stationary Glass 02 installs on the outside and the Upper guide rail 03 goes on the inside of the shower Make sure the Stationary glass 02 and the Upper gu...

Страница 11: ...ith the placement of the Small Stationary Glass 23 Position the Small Stationary Glass 23 onto the threshold and butt it up against the wall Align the Small Stationary glass bracket 21 with the hole i...

Страница 12: ...lass 23 Fig 9 4 See Fig 9 for details 9 Make sure that your Stationary glass 02 is parallel to the front edge of the threshold and mark it Slide the Guide Block 12 into the notch of the Stationary gla...

Страница 13: ...stalling the 72 model also remove the Small stationary panel glass 23 from the Upper Guide Rail 03 Remove the Guide Rail Brackets 08 from the Upper Guide Rail 03 and the Wall bracket 19 from the Stati...

Страница 14: ...10 Note that the adjustment set screws must be aligned vertically for easier access to adjust for level after the glass is installed See Fig 13 for details 13a To install Guide Block 12 Loosen the set...

Страница 15: ...instructed to do so Do Not attempt to lift the door glass with the handle as this may result in damage to the glass and or serious personal injury Use a professional grade glass suction cup and an ass...

Страница 16: ...er the rail Loosen the bottom set screw and tighten the top set screw to raise the rail 14 Re position the Stationary glass 02 and Upper Guide rail 03 onto the threshold and fasten both sleeves of the...

Страница 17: ...stalling the 72 model attach the Small stationary panel glass 23 to the Upper Guide Rail 03 using the Small Stationary Glass Bracket 21 Attach the face plate to the Wall Bracket 19 See Fig 17 for deta...

Страница 18: ...a for details 17 Attach the Guide block face plate to the installed Guide Block 22 and tighten the set screw with the supplied allen wrench Make sure that the clear gaskets are in place to protect the...

Страница 19: ...shold 15 parallel with the front edge of the shower base or threshold Cover the other end of the Anti splash threshold 15 with the Threshold cap 16 against the wall See Fig 20 for details 20 Temporari...

Страница 20: ...Door Glass 05 does not touch the bottom of the Guide block 12 see details on page 23 See Fig 22 24 for details NOTE Do not attach the handle to the door glass until instructed to do so Do not attempt...

Страница 21: ...e 23 Press the Anti water strip 14 onto the vertical edge of the Stationary glass 02 and the Door Glass 05 Also press the Bumper strip 13 onto the vertical edge of the Door Glass 05 Fig 25 2 For the 7...

Страница 22: ...ig 26b 3 2 Stopper hole 1 Stopper Thread Lock Panel side Stopper 01 4 Door side Thread Lock 72 model with Right hand door installation 24 Position the Door Stoppers 01 and screw them tightly to the Up...

Страница 23: ...Apply a good quality mildew resistant silicone along the interior perimeter where the glass meets the wall and threshold and also along the Anti Splash Threshold 15 Please allow 24 hours for the sili...

Страница 24: ...the adjustment disk in place retighten the big bolt Use a shim or have an assistant hold the door glass in place while you retighten the big bolt 6 Re tighten the safety set screw to hold the big bol...

Страница 25: ...to dry To prevent scratching the surface never use abrasive cleaners or cleaning products that contain scouring agents Never use bristle brushes or abrasive sponges that may scratch the surface HARDWA...

Страница 26: ...TEL 866 731 2244 FAX 866 857 3638 DREAMLINE COM For more information on DreamLine Shower Doors and Enclosure please visit DreamLine com...

Отзывы: