Reference Manual ATOM one 4K mini
1. Disable LUT:
lut_enable 0 0
for LUT-1,
lut_enable 1 0
for LUT-2
2. Select LUT to configure:
out 1
for LUT-1,
out 2
for LUT-2
3. Select preset storage:
lut_preset 0
4. Set your sample points (includes clear):
lut_fun_rec709 <...>
5. Calculate LUT curve:
lut_interpolate
6. Enable LUT again:
lut_enable 0 1
for LUT-1,
lut_enable 1 1
for LUT-2
Switch Presets:
For
preset LUT
setup the following steps are required.
Presets are user sets to be loaded.
1. Disable LUT:
lut_enable 0 0
for LUT-1,
lut_enable 1 0
for LUT-2
2. Select LUT to configure:
out 1
for LUT-1,
out 2
for LUT-2
3. Select preset storage:
lut_preset 0
4. Calculate LUT:
lut_interpolate
5. Enable LUT again:
lut_enable 0 1
for LUT-1,
lut_enable 1 1
for LUT-2
12.1.2
How to setup a lookup table using the fast gamma function
When using fast gamma setup switch to lut mode 1:
lut_mode 1
Method 3:
The
fast gamma
lut setup will calculate the lut using a function by specifying
only the desired gamma value:
1. Select LUT to configure:
out 1
for LUT-1,
out 2
for LUT-2
2. Make sure LUT is enabled:
lut_enable 0 1
for LUT-1,
lut_enable 1 1
for LUT-2
3. Setup gamma value:
lut_fast_gamma <...>
12.1.3
How to setup a lookup table using the fixed gamma mode
When using the fixed gamma mode switch to lut mode 2:
lut_mode 2
Method 4:
The fixed gamma lut setup will calculate the lut by using different gamma
functions:
1. Select LUT to configure:
out 1
for LUT-1,
out 2
for LUT-2
2. Make sure LUT is enabled:
lut_enable 0 1
for LUT-1,
lut_enable 1 1
for LUT-2
3. Setup fixed gamma curve:
lut_fixed_mode <...>
12.2 lut_enable <index> <flag>
Enable function for look up table.
Index
Function
0
LUT-1 on SDI-1
1
LUT-2 on SDI-2