Dražice OKHE 100-SMART Скачать руководство пользователя страница 1

 

OPERATING AND 

INSTALLATION MANUAL 

TANK-TYPE WATER HEATER FOR VERTICAL 

MOUNTING 

OKHE 80, 100, 125, 160-SMART

  

 

Družstevní závody Dražice - strojírna s.r.o. 
Dražice 69, 294 71 Benátky nad Jizerou 
tel.: +420 /326 370 990 
Fax: +420 / 326 370 980 
e-mail: [email protected]

 

 

Содержание OKHE 100-SMART

Страница 1: ...TION MANUAL TANK TYPE WATER HEATER FOR VERTICAL MOUNTING OKHE 80 100 125 160 SMART Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou tel 420 326 370 990 Fax 420 326 370 98...

Страница 2: ...11 2 4 ELECTRIC WIRING 12 2 4 1 ELECTRIC INSTALLATION GENERAL INFORMATION 12 2 4 2 ELECTRONIC THERMOSTAT CONNECTION DIAGRAM 13 2 5 FIRST HEATER COMMISSIONING 14 2 6 PUTTING OUT OF SERVICE DISCHARGE 14...

Страница 3: ...WARE FOR MOBILE DEVICES 23 4 1 1 BASIC DESIGN 23 4 1 2 PAIRING SCREEN 24 4 1 3 MODE SECTION 24 4 1 4 PROGRAM SECTION 25 4 1 5 VACATION SECTION 27 4 1 6 STATISTICS SECTION 27 4 1 7 SETTING SECTION 28 4...

Страница 4: ...nstruction maintenance and other information on electrical water heaters The manufacturer reserves the right for engineering modification of the product The product is designed for permanent contact w...

Страница 5: ...rmostat with reaction to the consumption of hot water SMART HDO SMART mode with signal memory HDO 2 MANUAL Common thermostat MANUAL HDO Common thermostat blocked with signal HDO 3 PROG Common thermost...

Страница 6: ...nual setting of the required temperature set it only for the value which you need for the household operation Thus you will reduce electricity consumption as well as the amount of lime sediments on th...

Страница 7: ...MPTION FOR WARMING CONTENTS FROM 15 C TO 65 C kWh 4 8 6 8 9 5 TOTAL HEAT LOSSES kWh 24h 0 72 0 83 1 00 1 32 LOAD PROFILE M M M L DAILY ELECTRICITY CONSUMPTION kWh 6 19 6 31 6 59 12 03 WEEKLY ELECTRICI...

Страница 8: ...es the automatically measured anode rod The main electrical installation is placed in the plastic box assembled directly on the flange lid Water temperature and other comfort functions can be set mech...

Страница 9: ...NS Figure 2 OKHE 80 SMART OKHE 100 SMART OKHE 125 SMART OKHE 160 SMART A 730 875 1040 1237 B 731 876 1041 1223 C 578 724 754 1010 D 520 520 520 520 E 556 556 556 556 F 15 15 15 15 G 115 115 115 115 R...

Страница 10: ...liance or the thermostat to be set to minimum operation temperature of 60o C For proper operation drinkable water of adequate quality shall be used To avoid potential sediments we recommend that the d...

Страница 11: ...alve must be easily accessible as close to the heater as possible The inlet pipes must have at least the same clearance as the safety valve Safety valves with fixed pressure settings from the manufact...

Страница 12: ...potential disassembly or repair When assembling the security equipment follow u268 CSN 06 0830 2 4 ELECTRIC WIRING Do not plug the water heater in HDO socket it would not work properly in SMART mode...

Страница 13: ...aker disconnecting all poles of the network and a circuit breaker protector Installations in bathrooms lavatories and showers must comply with the SN 33 2000 7 701 standard To adjust the distance from...

Страница 14: ...n the combination faucet 3 Open the cold water inlet valve to the heater 4 As soon as the water starts running through the hot water valve the heater is filled and the valve can be closed 5 In case of...

Страница 15: ...utdown that exceeds 5 days Caution In doing so the cold water supply pipe and the connection fitting of the tank may get heated If the hot water heater does not work or if hot water is not withdrawn n...

Страница 16: ...ter that user consumes in relevant time leaving a certain reserve for case of unexpected water withdrawal In this phase water consumption data are collected and evaluated The obtained information is a...

Страница 17: ...heating spiral is blocked 3 1 5 OPTIMUM IN MODE MANUAL AND MANUAL HDO Recommended temperature for manual setting 55 C During this temperature the best efficiency of smart heater is achieved 3 1 6 PRO...

Страница 18: ...cludes the four digit seven segment LED display additionally to the heater The display example is below 3 3 FUNCTION DESCRIPTION In basic mode the panel displays water temperature and uses the light o...

Страница 19: ...ve mode ANTI FREEZE MODE DZ centre red Indication of active heating spiral gradual change of the light intensity with period approx 2 s permanent light in rest state Table 5 List of symbols 1 LED ANTI...

Страница 20: ...ifu najdete na www eon cz nizkytarif Pro zji t n platnosti doby n zk ho tarifu pro va e k dy zde sta zadat prvn uveden k d HDO kter naleznete na p stroji Pokud jste z oblasti ji n Moravy je k d HDO tv...

Страница 21: ...pages of electricity distributor also list the accurate times of your cheap and expensive product tariffs The frequency is always at the HDO receiver e g in figure 9 the frequency is 216 66Hz Referen...

Страница 22: ...TURE SETTING After turning the controller within scope of MANUAL mode temperature setting the display indicates the flashing temperature value which complies with the actual controller setting After f...

Страница 23: ...1 BASIC DESIGN The mobile application automatically adjusts the size and design of some user interface parts according to the display size and its turning width height In case of width display the mon...

Страница 24: ...chapter 4 1 7 Setting section 4 1 3 MODE SECTION After pairing the thermostat with the mobile device the width display in section Mode is set as the home screen in case of height display it displays...

Страница 25: ...hours in a week is performed by means of the field with round buttons in two steps After the first pressing of the specified round button the initial option location is marked then it is necessary to...

Страница 26: ...26 Figure 12 Setting the program mode Figure 13 Notification of the program mode...

Страница 27: ...r operation by means of annual graph for the last year and the last week together with total consumption Total consumption is measured from the day of the first boiler start or after pressing button R...

Страница 28: ...and it is possible to activate or deactivate the HDO function It is possible to set the name of the connected boiler which is suitable in situation the user owns more SMART heaters and it is necessary...

Страница 29: ...ZING TIME After the application start the actual thermostat time is automatically checked If the time differs from the time in the mobile device the user can press the button Synchronize to set time i...

Страница 30: ...and replacement of the regulation elements shall only be performed by an authorised service company The thermal fuse must not be turned off In case of thermostat defect the thermal fuse interrupts ele...