Страница 1: ...ND INSTALLATION MANUAL ELECTRIC WATER HEATER TO 5 1 UP IN TO 10 1 UP IN Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou tel 420 326 370 911 fax 420 326 370 980 e mail ex...
Страница 2: ...6 8 ELECTRIC INSTALLATION 8 9 HEATER COMMISSIONING 8 10 IMPORTANT NOTICE 9 10 1 DISPOSAL OF PACKAGING MATERIAL AND FUNCTIONLESS PRODUCT 9 11 FUNCTIONAL DEFECTS 10 12 FIRE FIGHTING REGULATIONS FOR INST...
Страница 3: ...of the product The product is designed for permanent contact with drinkable water It is recommended to use the product in indoor environment with air temperatures from 2 C to 45 C and a relative humi...
Страница 4: ...not recommended The time of heating service water is about 9 and 18 minutes depending on the volume 3 TECHNICAL DESCRIPTION The heater tank is steel enameled for pressure connection the electrical hea...
Страница 5: ...ng capacity of the wall If needed reinforce it Mount the water heater in vertical position only The fastening screws must have guaranteed spacing of 140 mm The mounting dimensions are specified in Fig...
Страница 6: ...increases which causes water dripping from the combination faucet pipe You will not prevent water from dripping by strong tightening of the combination faucet valve but you may damage the combination...
Страница 7: ...ly follow the guide provided by the safety equipment manufacturer It is necessary to check the safety valve each time before putting it into operation It is checked by manual moving of the membrane fr...
Страница 8: ...cal network is made after the water supply installation of the heater and the filling of the heater with water Follow the rules of protection against electrical injuries in accordance with standard CS...
Страница 9: ...he water temperature in the heater exceeds 99 C If the water heater is mounted in enclosed areas inter ceilings built in structures and recesses ensure sufficient access to service fittings electrical...
Страница 10: ...t correspond with value set thermostat failure Table 3 Do not attempt to repair the faults yourselves Contact either a professional or service center It does not take much for a professional to remove...
Страница 11: ...uble free operation and a long service life of the heater By repeatedly heating the water lime scale settles on the walls of the tank Lime scale settling depends on the hardness of the heated water it...
Страница 12: ...r the signal light of the heater operation Figure 2 NAME FUNCTION DESCRIPTION 1 Signal light Indication of active heating Table 4 The front panel is equipped with a protective foil which must be remov...
Страница 13: ...IMENSIONS The abow supply point version The below supply point version Figure 3 Table 5 A mm B mm C mm D mm E mm TO 5 1 UP 330 265 290 275 TO 5 1 IN 338 93 290 275 TO 10 1 UP 465 400 290 275 TO 10 1 I...
Страница 14: ...14 16 2WIRING SCHEME Key 1 thermostat and reversible thermal fuse 2 Heating element 3 Operation indicator 4 Power supply Figure 4 13 7 2020...