User Guide

What is a room thermostat?

... An explanation for householders
A room thermostat simply switches the heating system on 

and off as necessary. It works by sensing the air temperature, 

switching on the heating when the air temperature falls below 

the thermostat setting, and switching it off once this set 

temperature has been reached. 
Turning a room thermostat to a higher setting will not make 

the room heat up any faster. How quickly the room heats up 

depends on the design of the heating system, for example, the 

size of boiler and radiators.
Neither does the setting affect how quickly the room cools 

down. Turning a room thermostat to a lower setting will result 

in the room being controlled at a lower temperature, and saves 

energy.
The heating system will not work if a time switch or programmer 

has switched it off.
The way to set and use your room thermostat is to find the 

lowest temperature setting that you are comfortable with, 

and then leave it alone to do its job. The best way to do this 

is to set the room thermostat to a low temperature – say 18ºC 

– and then turn it up by one degree each day until you are 

comfortable with the temperature. You won’t have to adjust the 

thermostat further. Any adjustment above this setting will waste 

energy and cost you more money.
If your heating system is a boiler with radiators, there will 

usually be only one room thermostat to control the whole 

house. But you can have different temperatures in individual 

rooms by installing thermostatic radiator valves (TRVs) on 

individual radiators. If you don’t have TRVs, you should choose 

a temperature that is reasonable for the whole house. If you do 

have TRVs, you can choose a slightly higher setting to make sure 

that even the coldest room is comfortable, then prevent any 

overheating in other rooms by adjusting the TRVs.
Room thermostats need a free flow of air to sense the 

temperature, so they must not be covered by curtains or 

blocked by furniture. Nearby electric fires, televisions, wall or 

table lamps may prevent the thermostat from working properly.

Controls and Display Layout

 

    

 

 

*  Temperature displayed while adjusting the settings. Once adjustment is  

 

  complete and after 5 seconds this will disappear. When the OFF button is 
  pushed the word ‘OFF’ is displayed here.
** When the OFF button is pushed the OFF temperature is displayed here.

 

 Simple Setting or Operating
 To set the required room temperature

  • The display normally shows the current room  

 

    temperature to within 0.5ºC 
  •  To adjust the required temperature, press the

    ‘+’ button to increase the temperature setpoint

    or the ‘-’ button to reduce the temperature 

    setpoint. The LCD will display the temperature 

    setpoint as it is being adjusted in the bottom 

   

left of the display.

 

• After a few seconds the display will return 

to  

 

    normal operation and will display the actual  

 

    room  temperature & the Sun symbol.

 

While adjusting the temperature during normal    

 operation, when you reach the maximum or  

 minimum possible setting the setpoint will flash to 

 indicate you cannot adjust the product further.

 To turn the Thermostat Off

 

• Press the ‘OFF’ button and the display will be as shown

 

 

• If the room temperature falls below the off setpoint

    temperature, the product will control at the OFF    
    temperature.

06515065001 ISS B

Tear here

Tear here

D1 & D1RF

Room Thermostat

Models: 

RF710/22190/22192

Invensys Controls Europe 

Technical Helpline: +44 (0) 845 130 7722 

www.draytoncontrols.co.uk

Installation Guide

RF PRODUCT ONLY
INSTALLATION OF SCR (RF Models only)

If you do not have the knowledge to install the SCR safely then you 
must arrange for a competent electrician to install it for you. Wiring 
must conform to the current IEE wiring regulations.
Prior to commencing the installation you must ensure the mains 
supply is switched off.

Installation Instructions
Read all installation and commissioning instructions before 
proceeding.
Do not switch on until ready to commission.

The system wiring must be able to be fully disconnected from the 
mains supply by a switch incorporated in the fixed wiring having a 
contact separation of at least 3mm on both poles. Fused at 3A. 

Location

The Digistat SCR (receiver) should be mounted in a convenient 
position, close to the boiler or central heating system wiring centre. 
(Care should be taken not to mount the SCR in a position where it 
is surrounded by metal objects or mains voltage cable, as this may 
interfere with the radio signal).
For the best performance install in an open space, at least 30cm 
distance from any metal objects including wall boxes and boiler 
housing.
It is recommended that the SCR is mounted on the wall nearest the 
final location of the DiRF room thermostat and not less than 
30cm from the boiler side panel.

Warning: Installing the SCR too close to the metal side panel 
or mains cables may interfere with the radio signal.

Combi boiler basic wiring layout

Zone control basic wiring layout

COMMISSIONING THE ‘WIRELESS SYSTEM’ (RF Models only)

Standard for all models

IMPORTANT: MULTIZONE INSTALLATIONS ONLY

If more than one ‘wireless system’ is fitted within the same property. 

ie. for controlling 2 or more zones (multi-zone) it is essential that the 

Digistat RF units are matched correctly to the relevant SCR. This is easily 

achieved by commissioning each Digistat and SCR in turn.

1.  Install (see installation instructions) and turn power on to the  

 

 

SCR (receiver). If a separate programmer is fitted, ensure that it is    

 

switched on. The red LED should come on.

2.  Push the ‘override’ button on the SCR once. The green LED should    

 

also come on. Check to see if the boiler and/or motorised valve  

 

 

are working.

3.  To enter ‘learn’ mode push the button marked 1 followed by 2  

 

 

(OVERRIDE) and hold both depressed together. The red LED  

 

 

should  flash for 2 seconds and then go out signifying the SCR is in    

 

learn  mode. Release both buttons.

4.  The red and green LED’s should both now be on.
5.  Take the Digistat RF and hold it within sight of the SCR (no closer  

 

 

than one metre).

6.   Remove the battery cover and fit the batteries. 
7.   The Digistat RF should now display the actual room temperature.  

 

If the unit has been stored in a cold place, it may take time to warm   

 

up.

8.  As soon as the batteries are fitted, the red LED on the SCR should    

 

flash for 7 seconds and then go out.  

 

The  green LED may be on or off depending on the room temperature  

 

at the time of commissioning.

9.  If the red LED remains on, remove the batteries on the Digistat RF,    

 

check the battery positions are correct, and once the display has  

 

 

faded, repeat steps 6 to 8.

10. Increase the ‘SET’ temperature on the Digistat RF by pressing the  

 

+ button until a flame symbol appears, in the left hand segment of    

 

the display. 

 

 

11. The red LED on the SCR should flash for 7 seconds. This confirms  

 

 

that the radio signal is being sent and received. After 7 seconds the    

 

red LED should go out and the green one come on.

12. Check to confirm that the boiler and/or motorised valves are  

 

 

working.

13. Decrease the ‘SET’ temperature on the Digistat RF by pressing the    

 

- button until the flame symbol disappears.

14. The red LED on the SCR should flash for 7 seconds. After 7 seconds    

 

both the red and green LEDs should go out. Check that the boiler    

 

and/or motorised valve have powered down.

15. Place the Digistat RF in the chosen operating position, (see Digistat    

 

RF location section) and repeat steps 10 to 14. Once you have  

 

 

confirmed the system operates correctly, fit and secure the Digistat RF  

 

to the wall (see installation instructions).

During normal operation the red LED on the SCR will flash for 7 seconds 

each time a radio signal is received from the Digistat RF. This will occur 

approximately every 5 minutes.
The green LED on the SCR denotes a call for heat (ON).

Once the system has been successfully commissioned, buttons 1 

and 2 on the SCR should not be pressed simultaneously, unless a 

replacement Digistat RF or SCR is fitted.

Fixing (minimum wall plate clearances shown)

1. Loosen the securing screws, remove the wallplate, and if surface  

 

wiring is to be used, snap out the cable entry strip on the bottom  

 

edge of the wallplate with a pair of pliers.
2. Fix the wallplate, terminals at the top, either direct onto the flat  
  wall using wall plugs and no 6 x1” wood screws or on a flush  

 

mounting single conduit box using M3.5 x 14 screws. Minimum  

 

wallplate clearances are shown.
3. Complete the wiring to the SCR wallplate in accordance with the  

 

relevant diagram, to comply with current IEE wiring regulations.
4. Place the SCR onto the wallplate and tighten the securing screws.

SCR wallplate clearances

Electrical

This product is double insulated and does not require an earth connection. 
The SCR should be wired to the combi boiler or central heating wiring using 
the correct type of cable or flex. The SCR should be wired in to replace 
hard wired room or programmable thermostats shown on the system or 
boiler wiring diagrams. Always check other manufacturers instructions for 
compatibility.

N     L     1     2      3

           

       

L

 

               

SCR 

Switched live 

from wiring 

centre 

Motorised valve 

To boiler 

and/or 

pump 

Radio signals  

to SCR - no wiring 

 

230V a.c.

fused 3A

N     L     1     2      3

           

SCR 

 L  - 
 N - 

Di RF 

Di RF 

Radio signals  

to SCR - no wiring 

Switched 

230V a.c.

fused 3A,

Internal 

boiler 

electronics 

External 

controls 

connections 

N     L     1     2      3

           

       

L

 

               

SCR 

Switched live 

from wiring 

centre 

Motorised valve 

To boiler 

and/or 

pump 

Radio signals  

to SCR - no wiring 

 

230V a.c.

fused 3A

N     L     1     2      3

           

SCR 

 L  - 
 N - 

Di RF 

Di RF 

Radio signals  

to SCR - no wiring 

Switched 

230V a.c.

fused 3A,

Internal 

boiler 

electronics 

External 

controls 

connections 

BOILER 

� 

� 

� 

� 

30cm Min 

Preferred side of boiler 

The range may be affected by 

composition/density and number of walls  

between the DiRF and SCR  

Radio Signal Range: 

30m Typically 

SCR 

06515065001 ISS B

Flame shows when calling for heat

Moon shows when in ‘Off’ 
(setback) mode

Sun shows when in ‘On’ (comfort) mode

**Room Temperature

*Setpoint 

Temperature

OFF Button

ON Button

+ or - buttons 

for setting adjustments

 To turn the Thermostat On

 

You can either:

  1. Press the ‘ON’ button and the display will

    show the On setpoint and the room 

    temperature.

    After a few seconds the On setpoint will 

    disappear from the display and the product

    will control at the On setpoint temperature.

  2. Press the ‘+’ or ‘-’ button and the display will

    show the Off setpoint and the room 

    temperature.

    Now press the ‘+’ or ‘-’ buttons until the   
    required setpoint temperature is shown.

    After a few seconds the setpoint will 

    disappear from the display and the product

    will control at the new temperature.

   

Note: The Digistat

+

1 Room Thermostat will 

    only control the heating when the Timeswitch

    or Programer is in a timed On period.

On

Receive  / Alarm

Override

2

1

Learn

Mode

Digistat

 

SCR

Wireless System

FEATURES
This product has the following user adjustable settings

  • Required room temperature (temperature setpoint) 
  • Off temperature setting
  • On temperature setting
  • Minimum & Maximum temperature settings

 